Kozy-World GFD2915 Скачать руководство пользователя страница 9

Ventilation Air From Outdoors 

Provide extra fresh air by using ventilation grills 
or ducts.  You must provide two permanent 
openings: one within 12

of the ceiling and one 

within 12

of the floor. Connect these items 

directly to the outdoors or spaces open to the 
outdoors. These spaces include attics and 
crawl spaces. Follow the 

National Fuel Gas 

Code, NFPA 54/ ANSI Z223.1, Section 5.3, Air 
for Combustion and Ventilation 

for required 

size of ventilation grills or ducts. 

 

IMPORTANT:

 

Do not provide openings for inlet  

or outlet air into attic if attic has a thermostat- 
controlled power vent. Heated air entering the attic will activate the power vent. Rework worksheet,  
adding the space of the Adjoining unconfined space. The combined spaces must have enough fresh air to 
supply all appliances in both spaces.

 

 

INSTALLATION 

 
NOTICE: 

This heater is intended for use as supplemental heat. Use this heater along with your primary 

heating system.  Do not install this heater as your primary heat source. If you have a central heating system, 
you may run system's circulating blower while using the heater. This will help circulate the heat throughout 
the house. 

WARNING: 

A qualified technician person must install the heater. Follow all local codes.

 

WARNING: 

Never install the heater. 

·

 

in a bedroom or bathroom 

·

 

in a recreational vehicle 

·

 

where curtains, furniture, clothing, or other flammable objects are less than 42 inches 
from the front, top, or sides of the heater 

·

 

in high traffic areas 

·

 

in windy or drafty areas 

CAUTION: 

This heater creates warm air currents. These currents move heat to wall surfaces next to heater. 

Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as tobacco 
smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls. 

WARNING: 

Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and 

adjoining side and back walls. 

 

INSTALLATION 

IMPORTANT: 

Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms 

without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and 
Ventilation, pages 7 through 9. 

 

CHECK GAS TYPE 

Use only the type of gas indicated on the plate. If your gas supply cannot meet that requirement, do not install 
heater. 

 

CLEARANCES TO COMBUSTIBLES 

Carefully follow the instructions below. This fireplace is a freestanding unit designed to set directly on the floor 
or on a mantel base. 

IMPORTANT: 

You must maintain minimum wall and ceiling clearances during installation. The minimum 

clearances are shown in Figure 4, page 10.  Measure from outermost point of fireplace. 

 

 

Figure 3 

 Ventilation Air from Outdoors 

Содержание GFD2915

Страница 1: ...heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air For Combustion and Ventilation section on page 7...

Страница 2: ...y result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS ITEM NO GFD2921 GFD2915 GFDC3029 Input Rating 28 000 BTU Hr 28 000 BTU Hr 28 000 BTU Hr 28 000 BTU Hr Gas Type Natu...

Страница 3: ...your guide to safe and proper operation of this heater Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this heater WAR...

Страница 4: ...le See Air for Combustion and Ventilation pages 7 through 9 If heater keeps shutting off see Troubleshooting pages 19 through 21 10 Do not run heater Where flammable liquids or vapors are used or stor...

Страница 5: ...itter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the...

Страница 6: ...An unvented room heater produces approximately one 1 ounce 30ml of water for every 1 000 BTU s 3KW s of gas input per hour Unvented room heaters are recommended as a supplemental heater for a room rat...

Страница 7: ...doorless passageways or ventilation grills between them Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in...

Страница 8: ...ng room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills between rooms See Ventilation Air from Outdoors page 9 b Vent room directly to the outdo...

Страница 9: ...ter in a bedroom or bathroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 42 inches from the front top or sides of the heater in high traffic ar...

Страница 10: ...d INSTALLATION ITEMS NEEDED Before installing heater make sure you have the items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connectio...

Страница 11: ...essible location The equipment shutoff valve is for turning on or shutting off the gas to the appliance Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going int...

Страница 12: ...ate heater between locked positions 3 Rotate and close cover over gas selection valve and reinstall screw 4 Remove hex plug with wrench provided from natural gas inlet of regulator and install into LP...

Страница 13: ...to all joints Bubbles forming show a leak Correct all leaks immediately Pressure Testing Heater Gas Connections 1 Open equipment shutoff valve see Figure 11 2 Open gas supply tank valve 3 Make sure co...

Страница 14: ...ontact any log If so reposition logs according to the log installation instructions in this manual Flames contacting logs will create soot IMPORTANT Make sure log does not cover any burner ports see F...

Страница 15: ...ilding Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in...

Страница 16: ...0 seconds release control knob Note If pilot goes out repeat steps 3 through 8 This heater has a safety interlock system Wait one 1 minute before lighting pilot again 10 Warning Make sure while the in...

Страница 17: ...incorrect pilot flame pattern The incorrect pilot flame is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down If the pilot fla...

Страница 18: ...blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could damage the pilot assembly 1 Shut off the unit including the...

Страница 19: ...phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING Make sure that power is turned off before proceeding WARNING Turn off and let cool...

Страница 20: ...meter is too small 3 Inlet gas pressure is too low 1 Burner orifice see Cleaning and maintenance Page 18 or replace burner orifice 2 Replace burner orifice 3 Contact your gas supplier Delayed ignition...

Страница 21: ...off when using furniture polish wax carpet cleaner or similar products When ignitor button is pressed in 1 Ignitor is positioned wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connecte...

Страница 22: ...arts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call KOZY WORLD PHONE NUMBER 814 643 1775 for referral inf...

Страница 23: ...age 22 of this manual KEY NO PART NUMBER DESCRIPTION QUANTITY 1 SIT545 200 T STAT VALVE 1 2 RV83FI 4 9 REGULATOR 1 3 FBB28D01 BURNER ASSEMBLY 1 4 NDD0308x400 ODS 1 5 FBB28D06 ODS INLET TUBE ASSEMBLY 1...

Страница 24: ...PARTS LIST GFD2921 GFD2915 This list contains replaceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 22 of this manual 24 13...

Страница 25: ...PARTS LIST GFDC3029 This list contains replaceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 22 of this manual 25 12...

Страница 26: ...e 1 Make sure point of the mitered edge of mounting strip touches the corner Use a level to ensure mounting strips are evenly balanced IMPORTANT Failure to balance mounting strips with a level could r...

Страница 27: ...g will lock the rear mantel top in position then use 14 screws to secure bracket as show in Figure 5 make sure the front and rear mantel top are in the same level 8 Move the surround back Set surround...

Отзывы: