kozy heat NCK-SL42-D Скачать руководство пользователя страница 5

#NCK-SL42-D

R.1

5

HUSSONG MFG. CO., INC.

 KOZY HEAT FIREPLACES

EN

F.  Test Inlet Pressure

IMPORTANT: For a proper pressure reading, apply the gas supply 

pressure tests with all other gas appliances on or at full capacity in the 

household.

Step 1:  Loosen the inlet (IN) pressure tap screw (counterclockwise) on 

the gas valve. See (A) in 

FIGURE 7.

Step 2:  Attach a manometer to the inlet pressure tap with a 

1/4

” (6mm) 

ID hose. 

Step 3:  Light the pilot and burner. Verify manometer reading is 

between the recommended minimum and maximum pressure 

settings. See 

TABLE 3

.

Step 4:  Turn off pilot and burner. 
Step 5:  Disconnect hose and tighten the inlet pressure tap screw 

(clockwise). The screw should be snug; do not over tighten.

Step 6:  Relight the pilot and burner.
Step 7:  Reattach the manometer to the inlet pressure tap to verify tap 

is completely sealed. Manometer should read no pressure.

Table 3, Inlet Gas Supply Pressures

Fuel

Minimum

Maximum

Natural Gas

5” WC (1.25 kPa)

10” (2.49 kPa)

G.  Test Manifold Pressures

Step 1:  Loosen the manifold (OUT) pressure tap screw 

(counterclockwise) on the gas valve. See (B) in 

FIGURE 7.

Step 2:  Attach a manometer to the outlet pressure tap with a 

1/4

” (6mm) 

ID hose. 

Step 3:  Light the pilot and burner. Verify manometer reading is 

between the recommended low and high pressure settings. 

See 

TABLE 4

.

Step 4:  Turn off pilot and burner.
Step 5:  Disconnect hose and tighten the outlet pressure tap screw 

(clockwise). The screw should be snug; do not over tighten.

Step 6:  Relight the pilot and burner. 
Step 7:  Reattach the manometer to the outlet pressure tap to verify tap 

is completely sealed. Manometer should read no pressure. 

Table 4, Manifold Gas Supply Pressures

Fuel

Low

High

Natural Gas

1.0” WC (0.24 kPa)

3.5” WC (0.87 kPa)

H.  Verify Operation

Step 1:  Light the pilot. Visually check the pilot flame to verify flame 

envelops the top of the flame sensor and extends far enough 

onto the burner for proper ignition. See 

FIGURE 8.

Step 2:  Turn the appliance off. 
Step 3:  Affix the gas type sticker on or near the gas valve.
Step 4:  Reinstall the glass frame assembly and safety barrier.
Step 5:  Light the pilot and burner. Visually check the main burner flame 

appearance (

FIGURE 9

) for proper ignition and operation of 

the fireplace. Refer to the installation manual for complete 

adjustment procedures. 

Step 6:  Complete and affix the ‘Gas Conversion’ labels as close to the 

rating plate as possible.

Step 7:  Verify the input rating of the converted appliance. See 

TABLE 5

.

Table 5, Input Ratings

Fuel

Minimum Input

Maximum Input

Natural Gas

21,000 Btu/h (6.15 kW)

42,000 Btu/h (12.3 kW)

Inlet pressure tap

Manifold pressure tap

Lazy, yellow flames - no adjustment necessary

Ideal Flame Appearance 

CORRECT PILOT FLAME APPEARANCE

BURNER PORTS

FIGURE 7, 

Pressure Check Taps

FIGURE 8, 

Burner Ports Location and Correct Pilot Flame Appearance

FIGURE 9, 

Ideal Burner Flame Appearance

Содержание NCK-SL42-D

Страница 1: ...APPLIANCE This gas conversion kit installation instructions must be used in conjunction with the installation and operation manual provided with the appliance Please read the appliance owner s manual...

Страница 2: ......

Страница 3: ...o disconnecting the electrical power before proceeding with the conversion A Prepare the Fireplace Step 1 Remove the safety barrier and glass frame assembly Step 2 Remove glass media and media dam Ste...

Страница 4: ...f venturi orientation closing the air shutter will achieve a desired yellow flame but may produce soot on the glass Opening the air shutter will cause a short blue flame that may lift off the burner S...

Страница 5: ...d burner Step 5 Disconnect hose and tighten the outlet pressure tap screw clockwise The screw should be snug do not over tighten Step 6 Relight the pilot and burner Step 7 Reattach the manometer to th...

Страница 6: ...ion de gaz A Pr paration du foyer tape 1 Retirez le pare tincelles et le cadre vitr tape 2 Retirez les braises de verre et bande de r tention retenir m dia tape 3 Retirez le plateau m dia du br leur t...

Страница 7: ...nt ou arri re donnera la couleur de flamme jaune d sir e mais cela peut encrasser la vitre suie Un venturi plus ouvert produira une flamme bleue plus courte qui peut sautiller du br leur De l gers aju...

Страница 8: ...ignez la veilleuse et le br leur tape 5 D branchez le tube avec manom tre et serrez la vis du raccord de test de pression de sortie sens horaire La vis doit tre viss e juste assez ne la serrez pas tro...

Отзывы: