Komfort Zone Kit #KZK-050
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
5
1.3 Dimensions and Overview
Figure 1.4, KZK-050 Dimensions
Figure 1.5, KZK-050 Overview
26
½
” Min
20’ Max
12
½
”
16
¾
”
9
¾
”
39”
2
½
” Minimum
clearance to
ceiling
CEILING
Minimum ½”
clearance to
combustibles
around pipe
The tubing that connects the plenum to the fireplace must be UL181 Class 0 approved air duct.
If you are mounting the plenum above the fireplace 10’ or less, use (1) #KZK-410 kit.
If you are mounting the plenum above the fireplace between 10’ to 20’, you will need (2) #KZK-410 kit and #KZK-CPL coupler kit.
3”
4”
1
7⁄8
”
12”
5”
8
11⁄16
”
12”
12”
12”
48”
½
”
STANDOFF
¾
”
STANDOFF
1
½
”
STANDOFF
½
”
STANDOFF
#KZK-050