Specifications

Control unit model

Maximum power 
of the electric heater, kW*
Supply voltage, V
Control voltage, V
Frequency, Hz
Temperature adjustment range, C
Hysteresis, C
Maximum time of operation, h
Maximum start delay, h
Control box dimensions, WхHхD, mm
Switching unit dimensions, WхHхD, mm
Weight, g
Operating temperatures of control box and 
switching unit, C

Relative humidity of the air 

of control box and 

switching unit, 

%

Operating temperature of temperature sensor, C
Storage temperature, 

С

T

ype of installation

GEOS

-

CONTROL 

12

12

GEOS

-

CONTROL 

18

18

220/380*

12

50 (60)

40 - 120

3
6

24

140х121х50
200х150х72

1100

to

 35

45-80

to

 130

Minus 10 to plus 60

indoor

Note: *no more than 30 A per relay switch.

6

Electrical  equipment  shall  be  installed  and  connected  in  accordance  with  PUE  and  GOST  R  IEC 
60335-2-53 by certified electricians with an electrical safety access qualification level III or higher.
 CAUTION! Before connecting and installing the control unit, make sure to check its completeness. It 
should be in accordance with the delivery list that can be found in the item's datasheet.
 CAUTION! When connecting and installing the control unit, follow the sequence of operations pro-
vided in this OM.
 To uninstall and disconnect the control unit, reverse the installation/connection sequence.

Fire safety requirements

 

CAUTION! 

Control units and electric heaters (sauna heaters) shall be installed and operated in accor-

dance with Resolution of the Government of the Russian Federation No. 390 dated 25 April 2012 (as 
amended on 6 April 2016) On the Fire Safety Regime and with the Fire Safety Regime Rules in the 
Russian Federation.
 

CONTROL UNIT INSTALLATION

OBVIOUS ADVANTAGES. 

INFORMED

 CHOICE

Содержание EOS-CONTROL 18

Страница 1: ...PERATING MANUAL GEOS SAUNA HEATER CONTROL UNIT Please read this instruction manual carefully before installing and using the control unit Keep it at hand throughout the entire life of the control unit...

Страница 2: ...C E I N F O R M E D C H O I C E O B V I O U S A D V A N O B V I O U S A D V A N T A G E S O B V I O U S A D V A N T A G E S I N F O R M E D C H O I C E I N F O R M E D C H O I C E O B V I O U S A D V...

Страница 3: ...ty valid CAUTION See that the retailer and the installation and maintenance contractors have lled in respective sections of the OM Remember that if the retailer fails to execute the Certi cate of Sale...

Страница 4: ...Electric heater operating parameters adjustment mode Operation mode In the operation mode the control unit ensures the following electric heater operating conditions Heating of the steam room In this...

Страница 5: ...plate 12 Control board 13 Knob 14 End cover 15 3 Fig 1b Control box Fig 1a General view 10 11 13 14 15 12 1 5 6 7 380 1 2 3 4 7 5000max 5000max SAUNA HEATERS GARDEN FIRE PITS SOLID FUEL BOILERS The bo...

Страница 6: ...ch on delayed start 10 5 Switching unit Fig 1d Body 20 Cover 21 Terminal block 22 Switching unit board 23 10 1 14 10 2 10 4 10 5 10 3 Fig 1d Switching unit The switching unit comprises a body 20 with...

Страница 7: ...5 To 3 phase mains To the electric heater To single phase mains N To single phase mains L1 Using jumpers To single phase mains To the electric heater SAUNA HEATERS GARDEN FIRE PITS SOLID FUEL BOILERS...

Страница 8: ...connected in accordance with PUE and GOST R IEC 60335 2 53 by certi ed electricians with an electrical safety access quali cation level III or higher CAUTION Before connecting and installing the cont...

Страница 9: ...wall in one horizon tal line at 79 mm intervals Hang the control box onto the impact anchors using the dedicated holes at the rear of the box s body CAUTION The control box shall be mounted within no...

Страница 10: ...play the parameters All adjustments are made by pressing and turning the encoder knob To switch the control unit on or off press and hold the knob for 2 s to switch from one adjustment mode to another...

Страница 11: ...he default delayed start time is zero If you skip this setting press the encoder knob but do not set the delayed start time the control unit will switch to the ON mode Operating modes of the control u...

Страница 12: ...nsor is connected Replace the temperature sensor Replace the temperature sensor Check the control cable Replace the temperature sensor Switching the control unit off To switch the control unit off pre...

Страница 13: ...nance instructions The user or a third party stored or transported the item in an improper manner The item was not used for its intended purpose The item was repaired by the user or a third party with...

Страница 14: ...manufacture Quality inspector Packer Stamp here Certi cate of Sale Name of retailer Date of sale ____ ___________ 20____ Stamp of retailer I have no claims to the quality of the product Buyer s signat...

Страница 15: ...n Connection Disconnection Connection Disconnection Record of warranty repair Description of defect Cause of malfunction Description of repair Date of repair ____ __________ 20____ Name of service con...

Страница 16: ...Manufacturer Teslatec LLC 12 Permskaya St Novosibirsk 7 383 304 94 30 www teslatec ru Manufacture for Koster LLC 60 9 Stantsionnaya St Novosibirsk tel 7 383 328 47 77 www koster pro...

Отзывы: