25
EN-115B_f.1420
SERVICE / CONFIGURATION:
Configuration
Adaptation of the heat pump:
* Changes in the configuration menu are possible after entering an access code. When prompted for an access code, turn the navigation dial to
the required code and confirm the code by pressing the dial. If you want to retract from the code request screen, hold the navigation dial or wait
until automatic return to main function screen.
Code: 987
• Central heatinge:
- Regulation:
Per curve - temperature in CH installation is calculated on the basis of outside temperature and room temperature based
on schedule,
Constant - in CH installation is equivalent to Supply temperature MAN, set individual for CH1 and CH2.
-
Glycol exchanger:
Yes - there is an additional exchanger in the system
No - there is no additional exchanger.
-
Building protection:
Yes - if the temperature in the building drops below 7C in the stand-by mode and the outside temperature is lower than
2C, heating will be turned on ,
No - protection is disabled..
-
Time of turning on the immersion heater: this parameter defines the time after which the heat pump is assisted it will be
additional source of heat if it does not reach the set values parameters. The time is counted from the moment the point
temperature is reached bivalent
[Configuration -> Heat pump -> Bivalent point]
. In case of if the outside temperature is
above the bivalent point temperature, the additional heat source will not be turned on. In case of need for an additional
heat source, the condition for its activation is the activation of the immersion heaters
[Configuration -> Heating element ->
use of immersion heaters: Yes]
,
-
Outside temp. Off: setting of selected temperature above which CH circuit will be switched off.
-
TO Calibration : calibration of the displayed outside temperature value.
Depending on the sign, the parameter is added to or subtracted from the measured values.
• INTERFACE:
-
BRIGHTNESS MIN: setting of the brightness of the display in stand-by mode.
-
BRIGHTNESS MAX: setting of the brightness of the display during the work.
- SOUND:
Yes - the sound of working dial/
No - there is no sound of the working dial.
-
DIAL SENSITIVITY: 1 - high / 4 - low.
• LANGUAGE
-
choice of language menu
• SYSTEM:
-
MSPC PROGRAM: shows the version of indoor unit controllers program
-
PW PROGRAM: shows the version of panel’s program
-
RESET: heat pump’s start-up
-
FACTORY SETTINGS: restore
9:37 Thu 22.04.2021
9:37 Thu 22.04.2021
Service / Configuration
Service / Configuration