background image

3

GB-073B_f.820

1.  Read  and  strictly  follow  the  installation  and  operating  instructions  to  ensure  

a long life and reliable unit operation.

2.  The unit should always be vented before the initial start-up.

3.  The unit should always be vented before initial start-up. Vent the unit each time 

after the water has been emptied from the heater or pipes (e.g. when water sup-

ply system has been repaired or maintained). Follow the procedure provided in 

section ‘Venting’.

4.  The unit should be connected to the electrical system and the reliability of fire 

protection system should be tested by a qualified person.

5.  The unit has to be earthed or neutrally grounded.

6.  The unit must be permanently connected to the mains.

7.  Electric installation should be equipped with residual current protective devices 

and other solutions which will ensure disconnecting the heater from the source 

of power (intervals between all their poles should not be less than 3 mm).

8.  The unit must not be installed in the place which is exposed to the danger of 

explosion and a place in which the temperature may drop below 0°C.

9.  The unit must be connected to the cold water supplies only.

10.  Do not use the device when the water has been emptied from the unit or pipes 

(e.g. when water supply system has been repaired or maintained). Turn off the 

tap immediately when you notice the water supply interruption. Vent the unit 

when the water is once again supplied to the piping system. Follow the procedure 

provided in section ‘Venting’.

11.  Unit’s cover must not be taken off while power is on.

12.  This unit can work only with the tap set included in the product box.

13.  The unit must not be installed where it will be exposed to the direct spray from 

shower head.

14.  The tap set works as an air vent and therefore, it cannot be connected to any 

valve or a connector that is not recommended by the manufacturer.

15.  Failure to install the filter on water supply pipe can cause unit’s damage.

16.  The filter should be cleaned after water supply system’s repair or maintenance 

works, when the water gets dirty, or after 1 year of use.

17.  Appropriate precaution must be taken when using hot water. Temperature of 

water over 40°C may cause hot feeling and it can be dangerous for children. 

18.  If the inseparable supply cord becomes damaged, it should be replaced at the 

manufacturer’s, in special repair shop, or by a qualified person in order to avoid 

all risks.

19.  It is necessary to regularly clean the shower head from the limescale.

Safety instructions

Содержание EPS2.P

Страница 1: ...EPS2 P Electric Instantaneous Water Heater Assembly and operating manual ...

Страница 2: ...physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance ...

Страница 3: ...ly 10 Do not use the device when the water has been emptied from the unit or pipes e g when water supply system has been repaired or maintained Turn off the tap immediately when you notice the water supply interruption Vent the unit when the water is once again supplied to the piping system Follow the procedure provided in section Venting 11 Unit s cover must not be taken off while power is on 12 ...

Страница 4: ...ts 5 Open the tap 6 Check for leaks 7 Vent the water installation 8 Connect the heater to the power source through the installation cable box 9 Turn on power supply fuse Electric installation should be equipped with residual current protective devices and other solutions which will ensure discon necting the heater from the source of power intervals between all their poles should not be less than 3...

Страница 5: ...ns supplies e g fuses insufficient flow rate through the heater e g dirty filter incorrect setting of the hot water tap The guarantee does not cover the above repairs If there is a fault in the appliance the heater does not work and all the above reasons do not occur contact the nearest authorised service point or the seller 1 Shut off the electric supplies 2 Turn the flow on turn the hot water ta...

Страница 6: ...n 2 1 2 6 Overall dimension length without a tap x width x depth mm 195 x 135 x 69 Weight with the tap kg 1 4 Conductor to connect with electrical installation 1 2m long with assembly terminals Min water resistivity at 15 C Ωcm 1100 Min connecting wires section mm2 3x2 5 The maximum allowed network impedance Ω 0 34 0 31 Water supply pipe section G1 2 Safety class IP25 Technical data ...

Страница 7: ...t for recycling Appropriate utili sation of used product prevents potential negative environmental influences that may occur as a result of inappropriate handling of waste In order to get more detailed information about recycling this product you should contact the local government unit waste management service or the shop where this product has been purchased ...

Страница 8: ...KOSPEL S A 75 136 Koszalin ul Olchowa 1 tel 48 94 31 70 565 serwis kospel pl www kospel pl ...

Отзывы: