background image

This  appliance  is  not  intended  for  use  by  persons  (including 

children) with reduced physical, sensory or mental capabilities or 

lack of experience and knowledge, unless they have been given 

supervision or instruction concerning use of the appliance by a 

person responsible for their safety. Children should be supervised 

to ensure that they do not play with the appliance.

!

Содержание EPS2.P

Страница 1: ...EPS2 P Electric Instantaneous Water Heater Assembly and operating manual ...

Страница 2: ...physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance ...

Страница 3: ...ly 10 Do not use the device when the water has been emptied from the unit or pipes e g when water supply system has been repaired or maintained Turn off the tap immediately when you notice the water supply interruption Vent the unit when the water is once again supplied to the piping system Follow the procedure provided in section Venting 11 Unit s cover must not be taken off while power is on 12 ...

Страница 4: ...ts 5 Open the tap 6 Check for leaks 7 Vent the water installation 8 Connect the heater to the power source through the installation cable box 9 Turn on power supply fuse Electric installation should be equipped with residual current protective devices and other solutions which will ensure discon necting the heater from the source of power intervals between all their poles should not be less than 3...

Страница 5: ...ns supplies e g fuses insufficient flow rate through the heater e g dirty filter incorrect setting of the hot water tap The guarantee does not cover the above repairs If there is a fault in the appliance the heater does not work and all the above reasons do not occur contact the nearest authorised service point or the seller 1 Shut off the electric supplies 2 Turn the flow on turn the hot water ta...

Страница 6: ...n 2 1 2 6 Overall dimension length without a tap x width x depth mm 195 x 135 x 69 Weight with the tap kg 1 4 Conductor to connect with electrical installation 1 2m long with assembly terminals Min water resistivity at 15 C Ωcm 1100 Min connecting wires section mm2 3x2 5 The maximum allowed network impedance Ω 0 34 0 31 Water supply pipe section G1 2 Safety class IP25 Technical data ...

Страница 7: ...t for recycling Appropriate utili sation of used product prevents potential negative environmental influences that may occur as a result of inappropriate handling of waste In order to get more detailed information about recycling this product you should contact the local government unit waste management service or the shop where this product has been purchased ...

Страница 8: ...KOSPEL S A 75 136 Koszalin ul Olchowa 1 tel 48 94 31 70 565 serwis kospel pl www kospel pl ...