background image

  ENG-003B                                                                                                                                                                 

7

By the term "flow regulation" we mean the setting of the water temperature 

to a comfortable level, by means of limiting/opening the rate of flow.

For this purpose,carry out the following steps:

-  insert the spanner [25] into the regulation valve [4],
-  set the hot water tap at maximum flow,
-  set optimum flow(check if the temperature is comfortable for you) using 

the spanner [25],

-  shut water flow using the tap,
-  take the spanner[25] out of the regulation valve [4].

  

3

Flow regulation

Picture 3  Regulation

 

[4]  -  regulating valve

 

[25]  -  regulating spanner

Chart 3  Characteristics

This heater has a differential pressure switch that starts heating automa-

tically when there is a proper rate of flow through the tap. There is a red 

indicator light  on the front case that shows that heating is on.

The  characteristics  shows  the  dependence  between  temperature  rise 

and flow rate per minute. The greater the flow rate the lower temperature 

of the water.

4

Get rid of boiler scale from the 

spray-head on regular basis.

Boiler scale may appear in the holes of the shower spray-head. Undo the spray-head and clean it with a hard 

brush.

Operation

Maintenance

Содержание EPJ.P-4

Страница 1: ......

Страница 2: ...ad and follow the instalation and operating instructions carefully to ensure the long life and reliable operation of this appliance Kospel S A may make minor changes if necessary in the appliance that will not be shown in the operating instruction so long as the main features of the heater remain the same ...

Страница 3: ...oils that assure maximum safety materials resistant to corrosion and chemically inactive with water copper brass stainless steel plastic This appliance will work with the attached tap set only The tap set works as an air vent and therefore cannot be con nected to any valve or a connec tor that is not recommended by the manufacturer You must not install in direct vicinity of the range of spray of t...

Страница 4: ...Drill holes at the marked places insert the screws 32 in there 5 Insert electric wires into the heater through the stuffing 5 picture 5 6 Install the heater onto the wall 7 Connect the mixer and the sho wer set with the heater 8 Connect electric supplies accor ding to Diagram 2 9 Fix the front case and screw it up 10 Install the shower holder 11 Let the mains water pressure to get to the mixer 12 ...

Страница 5: ...4 flow regulating valve 9 screws for fixing the case 12 filter 13 gasket 15 water supply 16 rosette 17 extension 19 tap body 20 sink shower switch 23 sprayhead 24 heating on indicator 27 front case 28 back case 30 fixing screw 32 pin 33 shower set ...

Страница 6: ...c connection in TN S system F2 dipolar circuit breaker L live wire N neutral wire PE earth wire The heater has to be ear thed or neutrally groun ded 2b 2a 1 Shut off electric supplies 2 Turn the flow on turn the hot water tap on in order to vent the water installation for about 15 30 seconds until the flow of water becomes constant and even 3 Shut the flow 4 Switch the electric supplies on Do it e...

Страница 7: ...w regulation Picture 3 Regulation 4 regulating valve 25 regulating spanner Chart 3 Characteristics This heater has a differential pressure switch that starts heating automa tically when there is a proper rate of flow through the tap There is a red indicator light on the front case that shows that heating is on The characteristics shows the dependence between temperature rise and flow rate per minu...

Страница 8: ...stuffing box 6 inlet cold water 7 outlet hot water 11 terminals 24 heat on indicator See general construction of the appliance in the diagram no 5 Safety temperature limiter 3 protects against overheating After the limiter goes off you can turn the hot water tap on but heating will not start Resetting the safety temperature limiter should be carried out by an authorised service 5 Costruction ...

Страница 9: ...imiter 3 H1 heating indicator 24 a failure of mains supplies e g fuses insufficient flow through the heater e g incorrect setting of the flow regulating valve refer to Flow regula tion The guarantee does not cover the above repairs If there is a fault in the appliance the heater does not work and all the above reasons do not occur contact the nearest authorised service 6 Faults ...

Страница 10: ...ration instruction EPJ P EPJ P water heater 1 piece Spanner for flow regulation 2 pieces Screw 1 piece Sleeve 1 piece Mixer set 1 piece Connecting tipe 2 pieces Shower set 1 piece Instalation and operation manual 1 piece Set contents ...

Страница 11: ...11 ENG 003B Installation and operation instruction EPJ P ...

Страница 12: ......

Отзывы: