FR;GB-030B_f.1105
21
LED
1 2 3 4 5
LED
1. Disconnect the NA contacts.
2. Set the pump on manual mode, see the
„Advanced settings” section.
3. Switch the boiler on (press
button).
4. Check pump mode is set to the
recommended factory setting (see Table
Below). To do this press button for no
more than 2 seconds. The LED’s should
illuminate the current operating mode
(see image).
5. In case the LED’s are signaling a different
operating mode from the recommended
table below, set the appropriate mode
according to the following instructions:
press button for longer than 2 seconds,
but less than 10 seconds, the pump then
enters programming mode. LEDs glow to
indicate the current settings. To go to the
other settings of the pump, in accordance
with the table, you can enter the correct
combination of glowing LEDs by pressing
if the LED combination is correct, by not
pressing the button for 10 seconds the pump will remember this setting and will exit
from programming mode.
Note: holding button for more than 10 seconds will lock the programming
mode on the pump so no changes can be made. To re-enable programming of
the pump settings hold button again for more than 10 seconds.
6. Make sure that a proper flow through the boiler is reached (the „B” indicator is on with
a constant light). The pump should self vent after a short time of running however, if
necessary, vent the pump in the following way:
• close the isolating valve on the outlet,
• leave boiler running for 15-30 s.
• open the isolating valve,
7. Switch the boiler off (hold
button for 2 seconds).
8. Connect NA contact.
9. Set the pump on automatic mode, see „Advanced settings” section.
10. Switch the boiler on (press button).
11. Set the temperature of the boiler to required temperature, see the „Operating” section.
Start up