Boiler connection to the central heating system
EKCO.LN2M boilers are equipped with an expansion vessel (capacity: 6l, pressure: 1,5
bar). The expansion vessel is sufficient for following capacities of the heating system at
given temperatures of the medium and central heating system pressure.
Shall the capacity of the wet central heating installation be larger, an extra expansion
vessel should be installed on it.
Temperature of heating medium
(feed and return)
Capacity of central
heating system
Pressure in central
heating system
[°C]
[l]
[bar]
85/70
58
1,5
70/55
79
55/45
103
50/40
115
45/35
128
PI - manometer
ZK - cut-off valve
RW - expansion pipe
NW - built-in expansion vessel (EKCO.LN2M)
NW 1 - expansion vessel
ZT - thermostatic valve
ZP - passage valve
G - radiator
F - magnetic filter
RT - room temperature thermostat
ZS - drain valve
TWV - three-way valve
ZAS - DHW Cylinder
Thw - WE-019/01 sensor
Text - WE-027 sensor