![Koso XR-01S Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/koso/xr-01s/xr-01s_instructions-manual_1999187006.webp)
●
Press the
Adjust button
to choose the
setting number.
●
Press the
Select button
to enter the
sensor point setting.
●
Ex: The circumference setting is
changed from 1,000 mm to 1,300 mm.
NOTE
Sensitive point
:
1 ~ 6
The setting value will flash!
●
Press the
Select button
to go back to the
circumference and sensing
point setting
screen.
●
Ex. To change the sensor point
from 1P to 6P
4-2
Fuel gauge resistance settings
●
Press the
Select button
to enter the fuel
gauge resistance setting screen.
●
Press the
Adjust button
to select the fuel
gauge resistance setting screen.
●
Ex: If the sensor point setting is 6P.
●
Press the
Adjust button
to choose the
setting number.
●
Ex. The sensor point is set to 1P
NOTE
The fuel gauge resistance setting
range
:
USER
、
100 Ω
、
250 Ω
、
270 Ω
、
510 Ω
、
1200 Ω
、
SW (turn off)
NOTE
The setting value will flash!
Custome fuel level resistance:
1) Manual - Please check 4-2-1
Fuel Level Resistance Manual
Setting Instructions.
2) Auto - Please check 4-2-2
Fuel Level Resistance Auto
Setting Instructions.
●
Ex: For a YAMAHA T-MAX 530, according
to the service manual, it’s resistance is
100 Ω.
●
Press the
Adjust button
to choose the
setting number.
The setting value will flash!
●
Ex: If the hig
hest fuel level is 10 Ω.
●
Press the
Select button
to the digit you
want to set.
●
Press the
Adjust button
to choose the
setting number.
wh026bb03b
4-2-1
Fuel Level Manual Setting
●
Press the
Select button
to enter the lowest
fuel level's resistance setting screen.
●
Press the
Select button
to go back to
the circumference and sensing point
setting screen.
●
Ex. To change the circumference and
sensing point setting from USER
to 100 Ω.
●
You will find
y
our fuel level sensor
resistance range in the e
lect
ronic
components section in the service
man
ual of your bike.
●
Select the correct resistance value for your
fuel float sensor.
The setting value will flash!
●
Ex: If the lowest
fuel level is 90 Ω.
●
Press the
Select button
to the digit you
want to set.
●
Press the
Select button twice
to enter
in the highest fuel level’s resistance setting
screen.
●
Ex: To change the lowest fuel level
setting from 0 to 90 Ω.
●
Press the
Adjust button
to choose the
setting number.
P.S.