16
Alternating Current (AC) OPERATION
・
Be sure all electric devices including the lines and plug connections are in
good condition before connecting to the generator.
・
Be sure any electric devices are turned off before plugging in.
・
Be sure the total load is within generator rated output.
・
Be sure the receptacle load current is within receptacle rated current.
・
Limit maximum power operation to 30 minutes.
1. Start the engine.
2. Plug into AC receptacle.
3. Make sure the voltmeter indicates the rated voltage.
4. Turn the AC circuit breaker to the “ON” position.
5. Turn on electrical devices one by one.
If an overloaded circuit causes AC circuit breaker to turn OFF reduce the
electrical load on the circuit, wait a few minutes and then reset AC circuit breaker.
STOPPING THE ENGINE
In an emergency:
Turn the engine switch to the “OFF” position.
In normal use:
1. Turn off any electric devices.
2. Turn the AC circuit breaker to the OFF position.
3. Disconnect any electric devices.
Disconnect the DC battery charging cables.
4. Turn the fuel valve to “OFF” position.
When using the generator at a high altitude, more than 1000m (3300ft)
above sea level, consult an authorized generator dealer.
CAUTION
CAUTION
NOTE