A. Safety Valve
In-built safety valve(pressure relief valve) is set to operate between 50 to 60 PSI. Service the safety
valve at least once in 6 months.
1. Close inlet water supply.
2. Remove dirt/scales from inside of the water connection.
3. Push rubber disk gently to ensure it is not stuck.
4. Do not tamper with the pressure adjusting screw otherwise pressure setting will get disturbed.
5. Fix back after replacing old fiber washer.
6. Check for any leakage before switching on the electric supply.
B. Thermal Cut-out
Hi-tech non self-resetting Thermal Cut-out set to disconnect electrical supply through two poles for
extra safety (orange lamp off). Please take the appliance to your near-by Koryo authorized service
center or call Koryo customer care.
C. Thermostat
Self-resetting. Thermostat set to operate between 65°C & 75°C. Automatic resetting type, ON/OFF
indication by red lamp.
Safety Devices
Specifications
Installation
Model
:
KWH-IN1
Power supply
:
230V AC, 50Hz, Single Phase
Wattage
:
3.0 KW
2
Rated pressure
:
30N/Cm
Inner container
:
Stainless steel
Outer body
:
Non-corrosive engineering plastic body
Heating Element
:
Long life copper element
Indicator Lamps
:
Red : Indicates operating load
Orange : ON : Normal Operation
OFF : Thermal Cut-out activated
1. Read Instruction Manual carefully and follow instructions. Also keep it for future reference.
2. Safety valves are pre-set for certain working pressure. Under any circumstances do not tamper/
over-tighten the safety valve.
3. Check Inlet Water Pressure at the place of installation. If it is more than rated Pressure,
use Pressure Reducing Valve (PRV).
4. Check for water line blockage. Ensure proper water flow.
5. Ensure flow of water from outlet before connecting electric power supply to the appliance
6. Do not use excessive force while tightening Inlet and Outlet Couplings. This may cause serious
damage to water Heater. Use cross spanner for tightening.
7. Check supply voltage at the place of installation. It should be 230V, AC.
8. Ensure proper earthing of electrical connection.
9. No extension cords to be used.
4
Содержание KWH-IN1 Hot Splash
Страница 1: ...INSTANT WATER GEYSER HotSplash KWH IN1 ...