308108
• Cooking hobs can be installed into worktops that are 30 to
50 mm thick.
• If the board is thicker than 40 mm, its inner edge should be
trimmed, or ground. Thus, suf
fi
cient air circulation will be
provided.
Ventilation
The electronics in the appliance need cooling. The appliance
will automatically switch off if there is insuf
fi
cient air circulation.
There are ventilation openings on the underside of the appliance.
It must be possible for cool air to be drawn in through these
openings. There are outlet openings on the underside and at the
front of the appliance.
A Lower kitchen cabinet with a drawer
• An opening at least 140 mm high must be provided on the
back wall of the cabinet, along its entire width. Furthermore,
a minimum of 6 mm clearance must be provided at the front
side, along the entire width of the cabinet.
• The hob is
fi
tted with a fan located in its lower part. In case
there is a drawer underneath the kitchen cabinet, no small
objects or paper must be kept there, as these could be sucked
in by the fan, causing damage to the fan or the entire cooling
system. Aluminum foil and in
fl
ammable substances or liquids
(e.g. sprays) should also not be stored in such drawers or
placed near the hob. Danger of explosion! There should be a
clearance of 20 mm between the drawer contents and the fan
entry slots.
18