TECHNICAL DATA
5
Krisis KARRE - User’s manual
Krisis Karré
100
125
160
220
Surface
25,2 m
2
30,7 m²
41,0 m²
59,2 m²
Line length incl. risers
6,10 - 6,42 m
6,86 - 7,22 m
6,86 - 7,25 m
7,50 - 7,80 m
Centre line length incl. risers
6,63 - 6,71 m
7,27 - 7,37 m
7,37 - 7,47 m
7,75 - 7,92 m
Number of lines/panels
18/16
18/16
22/20
26/24
Number of centre lines
5/2
5/2
8/2
9/2
Overall length
7,45 m
8,25 m
8,50 m
9,00 m
Max. load EN/LTF
100 kg
125 kg
160 kg
220 kg
Min. recommended load
50 kg
60 kg
80 kg
100 kg
Sink rate at max. load
4,6 m/s
4,5 m/s
4,8 m/s
4,6 m/s
Volume in ccm
3900
4700
5300
7300
Type certificate no.
EP 208.2018
EP 209.2018
EP 210.2018
EP 211.2018
Weight
1,17 kg
1,39 kg
1,78 kg
2,57 kg
INTENDED USE & GENERAL SAFETY INSTRUCTIONS
This rescue system is certified according to the standards EN 12491 and LTF NFL II 91/09, and has
been specially developed as a manually deployable rescue parachute for paragliding, powered
paragliding and hang gliding. Its use in connection with other flying activities, such as parachuting,
skydiving or base jumping, is not permitted!
The use of this rescue system requires appropriate flight training.Before each take-off, the pilot
must check all parts of the flight equipment for airworthiness.
CAUTION
: When practicing air sports, the pilot bears sole responsibility for all risks,
up to and including injury and death.Neither the manufacturer nor the seller of a
rescue system can be held responsible, nor can they guarantee the safety of the pilot.
PERMISSIBLE OPERATING TIME
The permissible operating time of the rescue system is ten years, starting with the first
commissioning. This also applies if the rescue system has never been deployed.
The date of the first commissioning must be noted on the approval label on the reserve riser at the
time of purchase. This date is decisive for the ten-year operating period as well as the regular
packing intervals, which are documented in the packing and inspection record booklet.
After ten years, the operating time can be extended by the manufacturer for an additional two
years. For this, it is required that the rescue system undergoes a factory inspection, and is
extensively tested and re-measured. If the condition proves satisfactory, the twoyear operating time
extension will be guaranteed and documented.