background image

 

 

 

 

(TEST METHODE) 

1-1-2. X-RADIATION 

 

WARNING : The only potential source of x-radiation is the picture tube, however 

  when the high voltage circuitry is operating properly, there is no possibility   

of an x-radiation problem.    The basic precaution is to keep the high voltage   

at the factory recommended level. 

 

  1) To measure the high voltage, use a high-impedance high-voltage meter. 

        Connect(-) to chassis and (+) to the CRT anode cap. 

 

  2) Turn the contrast control max. clockwise. 

 

  3) Measure the high voltage. The high voltage meter should indicate the following factory   

recommended level 

 

  4) If the actual level exceeds the max. factory set level, then immediate service is required to   

prevent the possibility of premature failure of components 

 

  5) To prevent X-RADIATION possibility, it is essential to use the specified picture tube. 

 

  6) 

The nominal high voltage is 24KV and not to exceed 27KV at zero beam current at rated 

voltage.

 

KORTEK Corporation

 

KTN-2001/1401

 

DEVICE

UNDER

TEST

LEAKAGE CURRENT

TESTER

READING SHOULD

NOT BE ABOVE 0.45mA

TEST ALL

EXPOSED METAL

SURFACES

2-WIRE

CORD

ALSO TEST WITH PLUG

REVERSED(USING AC

ADAPTER PLUG AS

REQUIRED)

EARTH

GROUND

Figurel 1

Содержание KTN-1401

Страница 1: ...1 SERVICE MANUAL KTN 2001 KTN 1401 Rev No A...

Страница 2: ...2 CONTENTS 1 PRECAUTIONS 3 2 PRODUCT SPECIFICATIONS 6 3 OPERATING INSTRUCTIONS 11 4 ADJUSTMENT 11 5 BLOCK DIAGRAM 13 6 GENERAL THEORY OF OPERATION 14 7 TROUBLESHOOTING GUIDE 25 8 WAVE FORM 31...

Страница 3: ...uncoated or melted wire is found then please do not try to replace the related parts and contact a qualified service person 2 Many electrical mechanical parts in this monitor have special safety relat...

Страница 4: ...high voltage The high voltage meter should indicate the following factory recommended level 4 If the actual level exceeds the max factory set level then immediate service is required to prevent the po...

Страница 5: ...ll any component or assembly disconnect PCB plugs or connectors connect any test component in parallel with an electrolytic capacitor 3 After servicing always check that the screw components and wirin...

Страница 6: ...hm MONITOR TERMINATIONS RASTER DIM ADJUST RANGE HORIZONTAL 360 407 mm RASTER DIM ADJUST RANGE VERTICAL 190 309 mm MODE 15 75 Khz PINCUSHION ALL BRIGHTNESS 3 0 MIS CONVERGENCE CENTER 0 75 0 8 mm MIS CO...

Страница 7: ...NS RASTER DIM ADJUST RANGE HORIZONTAL 250 285 mm RASTER DIM ADJUST RANGE VERTICAL 118 214 mm MODE 15 75 Khz PINCUSHION ALL BRIGHTNESS 3 0 MIS CONVERGENCE CENTER 0 64 0 7 mm MIS CONVERGENCE CORNERS 1 0...

Страница 8: ...8 2 2 PCB DIMENSIONS 1 MAIN PCB KTN 2001 1401 KORTEK Corporation...

Страница 9: ...ABLE CONNECTOR 2 2 2 PIN DESCRIPTION PIN NO P I N N A M E P I N1 RED P I N2 B L U E P I N3 G R E E N P I N4 B L A C K P I N5 Y L L OW P I N6 W H I T E RED G R E E N B L U E Y E L L O B L U E W H I T E...

Страница 10: ...VERTICAL SYNC G H NO 1 MODE STANDARD RESOLUTION H 624 V 200 SYNC POLARITY H POSI V POSI H FREQUENCY 15 750 PERIOD 62 4 SYNC 5 5 B P 5 8 ACTIVE 43 0 V FREQUENCY 60 PERIOD 16 62 SYNC 0 98 F P 1 06 ACTI...

Страница 11: ...time The monitor must be on for 30 minutes before starting alignment Warm up time is especially critical in color temperature and white balance adjustments 3 Signal Analog 0 714vpp positive at 75 inte...

Страница 12: ...V R603 B SELECT V SIZE FUNCTION ADJUST TO THE VERTICAL SIZE IS 190mm 3mm 118mm V R204 C SELECT H POSI FUNCTION ADJUST TO CENTER THE PATTERN WITHIN THE RASTER V R301 D SELECT V POSI FUNCTION ADJUST TO...

Страница 13: ...0 3 N V I D E O D E I V E R G B H V S I G N A L C O N T R O L 74L S 8 6 V E R T I C A L O U T T D A 1 6 7 5 A H O R I Z O N T A L T D A 2 5 9 5 S M P S O U TP U T F B T O U TP U T H V G3 G1 H V R G B...

Страница 14: ...f the complete monitor This will help when covering the sections individually The process from video signal to video display starts with the video signal generated from the source The signal is compos...

Страница 15: ...18 22 and 27 are B G and R Drive PIN 22 is fixed G Drive is fixed as a reference and PIN 18 and 27 control gains Refer to LM1203 Date Book for details 6 3 VIDEO OUT PUT AMP BIAS SECTION Signal supplie...

Страница 16: ...cuit operates as following As the DC is supplied to FE401 Gate through R402 overvoltage preventive resister and R403 Start Resister FE401 is turned on provides pulse to T401 PINs 2 and 4 and supplies...

Страница 17: ...is reduced to stop and protect the circuit C405 R404 and D405 are the circuits that protect FE401 from surge as it switches These sequential actions make power to be supplied to the secondary side of...

Страница 18: ...input from outside and built in OSC phase and coincide them which is mainly done by C308 C309 R306 R307 and is assured by adjustment of DC level with VR302 Generally connecting voltage is controlled w...

Страница 19: ...ltage and circuit is composed of C308 R309 R308 and VR302 6 6 VERTICAL OUTPUT CIRCUIT SECTION As IC 201 is built in with oscillating part within chip it has a function of its own oscillation amplifica...

Страница 20: ...2 C207 and VR204 and are controlled according to the value of V R204 PIN 8 is GND terminal PIN 9 and 10 are terminals to control V linearity and its circuit is as follows It is composed of R214 V R204...

Страница 21: ...1 This voltage varies according to the supplied voltage and here supplied voltage is boosted into higher voltage at T701 Then it becomes output as high voltage screen voltage focus voltage and etc 6 8...

Страница 22: ...s composed using the chip built in with 4 sets of EXCLUSIVE OR Gate circuit PIN 14 is Vcc supplying terminal for driving of chip PIN 1 2 4 5 9 10 12 and 13 are SYNC input terminal PIN 3 6 8 11 are out...

Страница 23: ...tage to adjust so that Back Raster is 0 1 F L 4 Measuring condition cross hatch pattern 3 High voltage adjustment method 1 Measuring terminal CRT anode 2 Adjusting V R 24KV 300V 3 Measuring condition...

Страница 24: ...time please confirm 30 F L 40F L at Full White 7 Other V R Adjustment 1 Measuring condition BS 120 cross hatch pattern 31 5 KHz 640 480 mode 2 Measuring method H size Min below 360mm 250mm Max over sc...

Страница 25: ...CHANGE FUSE NG OK OK CHECK BD401 CHANGE BD401 NG OK OK CHECK FE401 CHECK CHANGE Q401 NG OK OK CHECK Q402 Q403 CHANGE Q402 3 NG OK OK CHECK B 110V CHECK T101 NG OK OK CHECK COMPONENT CHANG D403 D404 D...

Страница 26: ...OK OK CHECK IC501 CHANGE IC501 NG OK OK CHECK 12V CHECK CHANGE D404 NG OK OK CHECK Q501 2 3 CHANGE Q401 2 3 NG OK OK CHECK CATHODE CHECK SG501 2 3 NG OK OK CHECK COMPONENT CHANG G1 LINE SG504 G2 LINE...

Страница 27: ...C801 NO SYNC PLOBLEM CHANGE IC801 NG OK OK CHECK Q801 301 CHANGE Q801 301 NG OK OK CHECK IC301 IC201 CHECK CHANGE C205 NG OK OK CHECK IC501 CHANGE IC501 NG OK OK END CHECK CHANGE C303 V R302 NG OK KOR...

Страница 28: ...ERTICAL DEFLECTION PROBLEM CHANGE D202 NG OK OK CHECK IC201 CHANGE IC201 NG OK OK CHECK 12V CHECK CHANGE D404 NG OK OK CHECK R218 CHANGE R218 NG OK OK CHECK DY CABLE CHANGE CDT NG OK OK END CHECK CHAN...

Страница 29: ...HORIZONTAL DEFLECTION PROBLEM CHANGE IC601 NG OK OK CHECK Q601 CHANGE Q601 NG OK OK CHECK DRIVE CHECK CHANGE IC301 NG OK OK CHECK FBT CHANGE FBT NG OK OK CHECK DY CABLE CHANGE CDT NG OK OK END CHECK C...

Страница 30: ...CHECK IC301 X RAY PROTECTION PROBLEM CHANGE IC301 NG OK OK CHECK VR303 CHANGE VR303 NG OK OK CHECK C311 OK CHECK D301 CHANGE D301 NG OK OK CHECK FBT CHANGE FBT NG OK OK END CHECK CHANGE C311 NG OK KO...

Страница 31: ...parts 1 FE401 DRAIN OUTPUT WAVEFORM 2 HORIZONTAL INPUT WAVEFORM 3 VERTICAL INPUT WAVEFORM 4 Q605 HORIZONTAL DRIVE WAVEFORM 5 Q604 HORIZON OUTPUT WAVEFORM 6 IC201PIN 1 VERTICAL OUTPUT WAVEFORM KORTEK C...

Страница 32: ...32 7 CLAMP IC501 PIN 14 WAVEFORM 8 Q702 COLLECTOR PULSE WAVEFORM 9 IC501 1203 PIN 25 IN PUT WAVEFORM 10 Q501 COLLECTOR WAVEFORM KORTEK Corporation KTN 2001 1401...