3

Basic operations

1. 

Each time you press buttons 1–4, the parameter assigned to the button in question 

changes one at a time and is shown in the popup screen in the display.

2. 

Once the desired parameter is shown, turn the value knob to edit the value.

3. 

Measurement starts/stops with each press of the START/STOP button.

  This product is a multi-tool intended for use with musical instruments. Do not use 

this product for anything under than its intended purpose, such as for calibrating 

measurement devices and so on.

Oscilloscope mode (SCOPE)

Oscilloscope mode lets you monitor the input signals coming from the four input sourc-

es (INPUT 1, 2 L/R).

Use VERTICAL to set the voltage range for the vertical screen direction. For example, a 

“5V” setting will display a 5 V voltage for each mark on the vertical axis.

Use HORIZONTAL to set the time scale in the horizontal screen direction.

Use the DISPLAY setting to select the inputs shown on the oscilloscope, display multiple 

inputs separately or stacked on top of each other, or to display two inputs as an image 

for comparing two different signals. To compare two signals with each other, set the 

vertical and horizontal directions to the same setting.

Use TRIGGER to set the timing at which the scope measures the signal input.

Explanations of each parameter

Button#/NAME

Pop Up

Enc. Push

Enc. Value

1: DISPLAY

Overlay

1 ch mode

1L, 1R, 2L, 2R

2 ch mode

1L-1R, 1L-2L, 1R-2R, 2L-2R

4 ch mode

---

Separate-2

2 ch mode

1L-1R, 1L-2L, 1R-2R, 2L-2R

4 ch mode

---

Separate-4

---

---

X-Y

XY

1L-1R, 1L-2L, 1R-2R, 2L-2R

XY-TY overlay

1L-1R, 1L-2L, 1R-2R, 2L-2R

2: VERTICAL

1L

Input mode

(DC

n

AC)

Vertical range:  

10 mV–10 V/div (10 m, 20 m, 

50 m, 0.1, 0.2, 0.5, 1, 2, 5, 10)

1R
2L
2R

3: HORIZONTAL

Sec/Div

---

Horizontal range:  

50 us–1 s/div (50, 100, 200, 

500, 1 m, 2 m, 5 m, 10 m, 

20 m, 50 m, 100 m, 200 m, 

500 m, 1)

Position

Set position to zero Change center position

4: TRIGGER

Auto

Set trigger level to 

zero

Set trigger level:  

−5.00 V–5.00 V (0.01 V step)

Rise
Fall
Rise single
Fall single

START/STOP

---

---

Oscilloscope RUN/STOP

* Buttons 1–4 + value knob (when the popup is shown): edits the popup item.

* Button 4 + value knob: push to edit what is triggered.

* START/STOP button: controls the run/stop and single mode standby.

Function generator mode (WAVE)

Use this mode to output oscillator /noise signals that can be handled as audio, or to out-

put LFO/PULSE/envelope signals that can be handled as CV signals. OUTPUT 1 and 2 

are completely independent, and different categories can be selected and used for each.

Button 1 (button 3): explanations of each parameter

Button#/NAME

Pop Up

Enc. Push

Enc. Value

1 (3): CATEGORY

CATEGORY

---

Oscillator
LFO
Noise
Pulse
Envelope

VOLUME

Vpp 

n

 dBu

Set Output Level

CYCLE MODE ---

Cont.
1-Shot
Push

INPUT 

MONITOR

---

Off
Input 1L
Input 1R
Input 2L
Input 2R

Button 2 (button 4): explanations of each parameter

CATEGORY = Oscillator

Button#/NAME

Pop Up

Enc. Push

Enc. Value

2: EDIT 

WAVE TYPE ---

Sine, Square, Tri, Saw-Rise, Saw-

Fall

PITCH

Frequency 

n

 Note

0.01–10.00 kHz / C-0 – G9

SHAPE

Set shape to 50%

0–100%

PHASE

Set phase to 0°

−180 – +180°

CATEGORY = LFO

Button#/NAME

Pop Up

Enc. Push

Enc. Value

2: EDIT 

WAVE TYPE

---

Sine, Square, Tri, Saw-Rise, Saw-

Fall

FREQUENCY Frequency 

n

 BPM

0.01–10.00 kHz / 0.5–600.0 BPM

DIRECTION

Set direction to ±

−, ±, +

PHASE

Set phase to 0°

−180 – +180°

CATEGORY = Noise

Button#/NAME

Pop Up

Enc. Push

Enc. Value

2: EDIT 

WAVE TYPE ---

White, Pink

TIME

Period 

n

 BPM

1 ms–10.0 s / 0.5–600.0 BPM

---

---

---

DUTY

Set duty to 100%

0–100%

CATEGORY = Pulse

Button#/NAME

Pop Up

Enc. Push

Enc. Value

2: EDIT 

WAVE TYPE ---

Positive, Negative

TIME

Period 

n

 BPM

1 ms–10.0 s / 0.5–600.0 BPM

---

---

---

DUTY

Set duty to 50%

0–100%

CATEGORY = Envelope

Button#/NAME

Pop Up

Enc. Push

Enc. Value

2: EDIT 

WAVE TYPE ---

Linear, Exp.

TIME

Period 

n

 BPM

1 ms–10.0 s / 0.5–600.0 BPM

SHAPE

Set shape to 50%

0–100%

DUTY

Set duty to 100%

0–100%

Spectrum analyzer mode (FFT)

Spectrum analyzer mode uses an FFT (fast Fourier transform) function that lets you 

monitor the reference waveform along with a frequency spectrogram of the input 

signal. This is useful for seeing where the effects of a filter or the changes you make to a 

waveform appear in the frequency bands.

Explanations of each parameter

Button#/NAME

Pop Up

Enc. Push

Enc. Value

1: INPUT

--

Input mode: AC

n

DC 1L, 1R, 2L, 2R

2: VERTICAL

INPUT 1L Input mode: AC

n

DC VERTICAL RANGE:  

10 mV–10 V/div (10 m, 

20 m, 50 m, 0.1, 0.2, 0.5, 1, 

2, 5, 10)

INPUT 1R 
INPUT 2L 
INPUT 2R 

3: HORIZONTAL

Sec/Div

---

Time range (50 us–1 s/div)

Position Set position to zero

Change center position

FFT 

Range

---

FFT max Range 

(1 k–20 kHz)

FFT 

Position

---

FFT min Range (0–19 kHz)

4: TRIGGER

AUTO, 

Rise, Fall

Set trigger level to 

zero

Set trigger level: 

−5.00 V–5.00 V (0.01 V step)

START/STOP

-

-

FFT RUN/STOP

* Buttons 1–4 + value knob (when the popup is shown): edits the popup item.

* START/STOP button: controls the run/stop and single mode standby.

Содержание Nu:Tekt NTS-2

Страница 1: ...ator mode WAVE 3 Button 1 button 3 explanations of each parameter 3 Button 2 button 4 explanations of each parameter 3 CATEGORY Oscillator 3 CATEGORY LFO 3 CATEGORY Noise 3 CATEGORY Pulse 3 CATEGORY Envelope 3 Spectrum analyzer mode FFT 3 Explanations of each parameter 3 Tuner mode TUNER 4 Explanations of each parameter 4 Global mode 4 1 Input 4 2 SETTINGS 4 3 SETTINGS 4 Specifications 4 Published...

Страница 2: ... Long press the power button again to turn the unit off Auto power off function The Nu Tekt NTS 2 features an auto power off function that automatically turns the unit off after one hour has elapsed without the knob switches buttons or other controls being operated The auto power off function is enabled by factory default Auto power off can be disabled using the steps below 1 Use the mode button t...

Страница 3: ...oise signals that can be handled as audio or to out put LFO PULSE envelope signals that can be handled as CV signals OUTPUT 1 and 2 are completely independent and different categories can be selected and used for each Button 1 button 3 explanations of each parameter Button NAME Pop Up Enc Push Enc Value 1 3 CATEGORY CATEGORY Oscillator LFO Noise Pulse Envelope VOLUME Vpp n dBu Set Output Level CYC...

Страница 4: ...s displaying again from the left side When this is Scroll the signal is scrolled to the left and displayed once the display reaches the position set in Position To show the signal over the entire screen move the Position all the way to the right edge 3 SETTINGS Parameter Display Notes Power Battery Type Alkaline Ni MH Selects the battery type Auto Power Off USB 5 min 15 min 30 min 1 hour inifiniit...

Отзывы: