SAMPLING: Page Menu Commands 9–5: TFX2
605
SAMPLING: Page Menu Commands
Sample Mono To Stereo (Change Sample Type)
Delete MS (Delete Multisample)
Rename MS (Rename Multisample)
Convert MS (Multisample) To Program
MS Mono To Stereo/MS Stereo To Mono
(Change Multisample Type)
Select Directory/File for Sample To Disk
Remarks on editing stereo
samples
• For stereo samples, the L channel and R channel samples
are edited simultaneously. If you wish to edit only the L
channel or R channel, select a mono multisample, and
select either the L channel or R channel sample for
editing.
• For stereo samples, the display will indicate “Save to
No.(L)” and “(R).” These respectively specify the
writing-destination sample numbers for the L and R
channels.
• If you
Copy
a mono sample into the buffer, and then
Insert
,
Mix
, or
Paste
it to a stereo sample, the data will
be inserted, mixed, or pasted into both the L and R sides.
(The result is that a stereo sample will be created.)
If you
Copy
a stereo sample into the buffer, and then
Insert
,
Mix
, or
Paste
it to a mono sample, the L- and R-
side data in the buffer will be mixed to mono, and then
inserted, mixed, or pasted. (The result is that a mono
sample will be created.)
You can also use these commands if you wish to mono-
mix a stereo sample and use it as a mono sample.
However, be aware that once a sample has been mixed to
mono, it is no longer possible to return it to a stereo
sample.
Start and End settings
When using the Sample Edit,
Truncate
– “Volume Ramp”
and the Loop Edit,
Truncate
to edit the waveform data of a
sample, you must first use
Start
and
End
to specify the
region that you want to edit, and then select and execute a
page menu command.
There is no compare function that lets you return the
edited result to the state before editing. If you wish to
preserve the unedited sample, uncheck the
Overwrite
*1
item in the dialog box of each page menu command
before you execute.
Note:
To edit the
Start
,
Loop Start
, or
End
points, use Loop
Edit.
If the above parameters are located within an area of sample
addresses that are deleted or moved by your editing, they
will automatically be moved.
The
Loop Start
and
End
(2–1d) must be at least eight
samples apart. If you try to use the
Truncate
,
Cut
, or
Rate Convert
commands, but the results of the
commands would cause the
Loop Start
and
End
to be
separated by less than eight samples, you’ll see the error
message “Sample length is shorter than minimum.”
Please set the
Start
and
End
appropriately.
About Overwrite
When
Overwrite
is
unchecked
: When the command is
executed, the edited sample will be saved in a different
sample number. The unedited sample will remain without
change.
When
Overwrite
is
checked
: When the command is
executed, the edited sample will be overwritten onto the
original sample (number). The original sample will be
modified.
Содержание NAUTILUS Series
Страница 1: ...i Parameter Guide E 1...
Страница 264: ...EXi STR 1 Plucked String 254...
Страница 358: ...EXi MOD 7 Waveshaping VPM Synthesizer 348...
Страница 368: ...EXi SGX 2 Premium Piano 358...
Страница 458: ...SEQUENCER mode 448 Track 02 16 Track Number For more information please see Track 01 Track Number on page 446...
Страница 568: ...SEQUENCER mode 558...
Страница 580: ...SET LIST mode 570...
Страница 738: ...MEDIA mode 728...
Страница 753: ...Insert Effects IFX1 IFX12 Routing 743 Fig 2 2e...
Страница 961: ......