13
The RS-485 multi-drop mode offers 32 nodes at same current loop bus, and it is recommended
to enable 120ohm line terminator to obtain better data communication reliability in RS-485 bus.
It is not necessary to add extra 120 ohm line terminator on each RS-485 node, just enable the
DIP Switch-4 of line Terminator Resistor of 1
st
and last node of RS-485 bus for reliable current
looping.
Note: the RS-485 2-wire communication speed will downgrade to
57600bps if RS-485 2-wire link distance up to 1.2KM.
2.3
Install the USB /Serial Converter onto DIN Rail
The DIN Rail clip is screwed on the rear panel of JetCon 1100 and JetCon 1200, which
supports EN 50022 type rail installation.
The below diagram includes the dimension of
EN50022 rail for your reference.
RS-485 4-wire communication mode (Full Duplex Communication mode)
RS-485 2-wire communication mode (Half Duplex Communication)