24
GB
Technical data
Nominal voltage:
220-240 V~
Frequency:
50 / 60 Hz
Standby power:
< 0,1 W
Detection angle:
180°
Lens design:
3 levels
Detection range: (at 20°C)
approx. 9 m with an installation height of approx. 1.2 - 1.5 m
approx. 8 m with an installation height of approx. 1.5 - 2 m
Recommended installation height:
1,2 m to 2 m
Duty cycle (delay time):
7 levels: 5 sec. / 20 sec. / 1 min. / 5 min. / 15 min. / 30 min. / test
Test function: 2 sec.
Twilight threshold:
5 to 300 Lux (night/day operation)
4 levels: 5 / 30 / 100 / 300 Lux /
1min.
20sek.
5sek.
Test
5min.
15min.
30min.
Zeit
Meter
300
100
30
5
300
100
30
5
300
100
30
5
(learning function)
Save function ambient brightness
Connection equipment:
Basic wiring: 2 wires (L, connection for consumers)
Connection type:
screw terminals
Settings:
ON: permanent ON for 2h
OFF: permanent OFF
AUTO: automatic
Incandescent lamp:
5-300 W
Halogen lamp:
5-300 W
Low-voltage halogen lamp load:
5-150 W
Fluorescent lamp:
5-150 W (uncompensated)
LED lamps:
5-100 W
Dimensions:
(50 x 50 x 65) mm
Operating temperature:
0 °C --> +45 °C
Degree of protection:
IP 40