6
Function setting
Radio magnetic sensor is only a transmitter.
Any number of receivers in the transmitting range
can be programmed to the switching command.
Combination with other free-control devices
Plug the plug-in jumper into position
for the
following applications:
• Signal evaluation by means of the radio alarm
station
• Switching of radio receivers
- Flush-mounted receiver 1-channel 3-wire
- Flush-mounted receiver 1-channel 2-wire
- Flush-mounted receiver 2-channel or blinds
- Flush-mounted receiver buttons or time function
- Flush-mounted receiver dimmer function for
electronic transformers (switch on/off function)
- Flush-mounted receiver dimmer function for
conventional transformers (switch on/off function)
- Lamp socket
- Adapter switch function
- Adapter dimmer function (switch on/off function)
- Grounding-type multiple socket outlet
Sabotage contact is not active here.
Plug the plug-in jumper into position
for the
following applications:
• Signal evaluation by the radio burglary alarm
center
• Signal evaluation by the PC-software for burglary
alarm center
Sabotage contact and magnetic sensor are constantly
monitored here.
Programming to radio receiver and/or radio alarm station
Set plug-in jumper
.
Activate the programming mode of the receiver (see
separate operating instructions).
Select the switching behavior of the magnetic sen-
sor for the operating scenario. To do this, press the
PROG button
for different lengths of time.
Operating scenario 1:
Transmit the signal „switch ON command“ if a door
or window is closed.
Transmit the signal „switch OFF command“ if a door
or window is opened.
Set operating scenario 1:
Press PROG button
< 1 second.
LED
illuminates for 3 seconds.
Magnetic sensor transmits two signals
First ON then OFF signal within 2 seconds
Receiver LED must blink 2x.
Programming process is terminated automatically.
Operating scenario 2:
Transmit the signal „switch ON command“ if a door
or window is opened.
Transmit the signal „switch OFF command“ if a door
or window is closed.
Set operating scenario 2:
Press PROG button
> 2 seconds.
LED
blinks briefly
Magnetic sensor transmits two signals:
First OFF then ON signal within 2 seconds
Receiver LED must blink 2x.
Programming process is terminated automatically.