background image

Technical Data

9

G

G

G

KA4C4P _ _R

4000

131/50

115/100

60/50

19.0/17.0

145

150

155

G

G

G

KA4C4P _ _R56

4000

131/50

115

50/60*

17.0/19.0

145

150

155

G

G

G

K2A4C4P _ _L

4000

131/50

230/200

60/50

9.0

145

150

155

G

G

G

K2A4C4P _ _L5

4000

131/50

230

50

7.6

145

150

155

G

G

G

KA4C5P _ _R

5000

131/50

115/100

60/50

19.0/17.0

145

150

155

G

G

G

KA4C5P _ _R56

5000

131/50

115

50/60*

17.0/19.0

145

150

155

G

G

G

K2A4C5P _ _L

5000

131/50

230/200

60/50

9.0

145

150

155

G

G

G

K2A4C5P _ _L5

5000

131/50

230

50

7.6

145

150

155

G

G

G

KA4C6P _ _R

6000

131/50

115/100

60/50

19.0/17.0

145

150

155

G

G

G

KA4C6P _ _R56

6000

131/50

115

50/60*

17.0/19.0

145

150

155

G

G

G

K2A4C6P _ _L

6000

131/50

230/200

60/50

9.0

145

150

155

G

G

G

K2A4C6P _ _L5

6000

131/50

230

50

7.6

145

150

155

G

G

G

KA4C7P _ _R

7000

131/50

115/100

60/50

19.0/17.0

145

150

155

G

G

G

KA4C7P _ _R56

7000

131/50

115

50/60*

17.0/19.0

145

150

155

G

G

G

K2A4C7P _ _L

7000

131/50

230/200

60/50

9.0

145

150

155

G

G

G

K2A4C7P _ _L5

7000

131/50

230

50

7.6

145

150

155

G

G

G

KA3C8P _ _R

8000

115/50

115/100

60/50

19.0

145

150

155

G

G

G

KA3C8P _ _R56

8000

115/50

115

50/60*

17.0/19.0

145

150

155

G

G

G

K2A4C8P _ _L

8000

125/50

230/200

60/50

13.0

145

150

155

G

G

G

K2A4C8P _ _L5

8000

115/50

230

50

12.5

145

150

155

G

G

G

KA3C9P _ _R 

9000

115/50

115/100

60/50

19.0

145

150

155

G

G

G

KA3C9P _ _R56

9000

115/50

115

50/60*

17.0/19.0

145

150

155

G

G

G

K2A4C9P _ _L 

9000

125/50

230/200

60/50

13.0

145

150

155

G

G

G

K2A4C9P _ _L5

9000

115/50

230

50

12.5

145

150

155

G

G

G

KA3C10P _ _R 

10000

115/50

115/100

60/50

19.0

145

150

155

G

G

G

KA3C10P_ _R56

10000

115/50

115

50/60*

17.0/19.0

145

150

155

G

G

G

K2A4C10P_ _L

10000

125/50

230/200

60/50

13.0

145

150

155

G

G

G

K2A4C10P_ _L5

10000

115/50

230

50

12.5

145

150

155

G

G

G

KA3C12P_ _R

12000

115/50

115/100

60/50

19.0

145

150

155

G

G

G

K2A4C12P_ _L

12000

125/50

230/200

60/50

13.0

145

150

155

G

G

G

K2A4C12P_ _L5

12000

115/50

230

50

12.5

145

150

155

Series

**

Ambient

**

Approximate

Height 

BTU/H

Temp. °F

Running

Weight (lbs.)

47 52 59

Model

Rating Max./Min.

Volts

Hz

Amps

P47

P52

P59

"

* Switchable. Switch is internally-mounted for security.

** Rating shown is for operation at maximum ambient temperature. 

"

115V, 60 Hz and 230V, 60 Hz models also perform at full capacity when operated

at 100V, 50 Hz or 200V, 50 Hz respectively.  No transformer is required.

"

Содержание Traditional K2A4C10P47L

Страница 1: ...IR CONDITIONER IT IS IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 www kooltronic com Find a...

Страница 2: ...page of the Kooltronic website I Introduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all...

Страница 3: ...prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operating this unit all electrical wiring must be checked to assure the proper connection...

Страница 4: ...y Use of incorrect type or amount of refrigerant will adversely affect performance and may damage the unit r Make sure that these parameters are met Failure to do so may result in permanent damage to...

Страница 5: ...by means of the vapor compression refrigeration cycle This takes place in a hermetically sealed refrigeration system utilizing either an air cooled or water cooled condenser heat exchanger The warm ai...

Страница 6: ...delayed until the system pressures rise 10 Operate the air conditioner for approximately ten 10 minutes During this period no unusual noise or vibration should be evident Both the evaporator and cond...

Страница 7: ...stability and a tight seal High strength mounting screws are recommended Attach the brass drain pan fitting and drain hose supplied to the drain exit on the bottom or lower side panel of the Air Condi...

Страница 8: ...ithin this area and equal or exceed size of cool air outlets FILTERED CONDENSER AIR INLET Ambient Air In CONDENSER OUTLET Warm Ambient Air Out COOL AIR OUTLET TO ENCLOSURE Drawings and Dimensions P47...

Страница 9: ...145 150 155 G G G KA3C8P _ _R56 8000 115 50 115 50 60 17 0 19 0 145 150 155 G G G K2A4C8P _ _L 8000 125 50 230 200 60 50 13 0 145 150 155 G G G K2A4C8P _ _L5 8000 115 50 230 50 12 5 145 150 155 G G G...

Страница 10: ...29 6015 00 129 6015 00 130 6015 00 130 Filter 12251F 12251F 12251F 12251F 8 000 to 12 000 BTU H KA3C_P47R KA3C_P47R56 K2A3C_P47L K2A3C_P47L5 KA3C_P52R KA3C_P52R56 K2A3C_P52L K2A3C_P52L5 KA3C_P59R KA3C...

Страница 11: ...Continued operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service Kooltronic Air Conditioners feature an easily removable inlet f...

Страница 12: ...valve fails it is strongly recommended that the Air Conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect refri...

Страница 13: ...ntrol Replace Thermostat or Relay Thermostat defective when applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit Contact Kooltronic Oversized for Appli...

Страница 14: ...eceived by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a s...

Отзывы: