VII. Specific Model Data

Mounting

Kooltronic Air Conditioners have been engineered to be installed easily. To avoid damaging
your Air Conditioner, please read the following information before installation.

Panel-Mounted Air Conditioners are equipped with two vertical mounting rails.
These rails can be mounted to any available vertical surface on the enclosure.

Refer to page 8 for the location of all mounting holes and cutouts.

Make sure the cutouts don't interfere with components inside your cabinet.

Proper alignment of all air inlets and outlets is essential for optimum performance
of the Air Conditioner.

All externally-mounted Air Conditioners are fully gasketed to ensure proper sealing.
This seal is necessary to maintain the integrity of the closed loop system.

Use all existing mounting holes to insure stability and a tight seal.

High strength mounting screws are recommended.

Attach the brass drain pan fitting and drain hose supplied to the drain exit on the
bottom or lower side panel of the Air Conditioner. The optional field installed
Condensate Evaporator is mounted underneath the Air Conditioner and the drain
hose is connected to the top fitting of the Condensate Evaporator. The drain hoses,
fittings and Condensate Evaporator must be removed before dismounting the Air
Conditioner, as they will not support the weight of the Air Conditioner unit.

The external drain hose must not be elevated above the exit port. Improper mounting
will impede the flow of condensate and may cause internal malfunctions.

CAUTION

If the Air Conditioner is mounted to the cabinet door you must be sure

that the door hinges will support the additional weight of the Air

Conditioner. Also be certain that when the door is opened fully, the

cabinet does not become unbalanced. The actual weight of the unit can

be found on page 9.

7

Содержание Traditional K2A4C10P47L

Страница 1: ...IR CONDITIONER IT IS IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 www kooltronic com Find a...

Страница 2: ...page of the Kooltronic website I Introduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all...

Страница 3: ...prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operating this unit all electrical wiring must be checked to assure the proper connection...

Страница 4: ...y Use of incorrect type or amount of refrigerant will adversely affect performance and may damage the unit r Make sure that these parameters are met Failure to do so may result in permanent damage to...

Страница 5: ...by means of the vapor compression refrigeration cycle This takes place in a hermetically sealed refrigeration system utilizing either an air cooled or water cooled condenser heat exchanger The warm ai...

Страница 6: ...delayed until the system pressures rise 10 Operate the air conditioner for approximately ten 10 minutes During this period no unusual noise or vibration should be evident Both the evaporator and cond...

Страница 7: ...stability and a tight seal High strength mounting screws are recommended Attach the brass drain pan fitting and drain hose supplied to the drain exit on the bottom or lower side panel of the Air Condi...

Страница 8: ...ithin this area and equal or exceed size of cool air outlets FILTERED CONDENSER AIR INLET Ambient Air In CONDENSER OUTLET Warm Ambient Air Out COOL AIR OUTLET TO ENCLOSURE Drawings and Dimensions P47...

Страница 9: ...145 150 155 G G G KA3C8P _ _R56 8000 115 50 115 50 60 17 0 19 0 145 150 155 G G G K2A4C8P _ _L 8000 125 50 230 200 60 50 13 0 145 150 155 G G G K2A4C8P _ _L5 8000 115 50 230 50 12 5 145 150 155 G G G...

Страница 10: ...29 6015 00 129 6015 00 130 6015 00 130 Filter 12251F 12251F 12251F 12251F 8 000 to 12 000 BTU H KA3C_P47R KA3C_P47R56 K2A3C_P47L K2A3C_P47L5 KA3C_P52R KA3C_P52R56 K2A3C_P52L K2A3C_P52L5 KA3C_P59R KA3C...

Страница 11: ...Continued operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service Kooltronic Air Conditioners feature an easily removable inlet f...

Страница 12: ...valve fails it is strongly recommended that the Air Conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect refri...

Страница 13: ...ntrol Replace Thermostat or Relay Thermostat defective when applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit Contact Kooltronic Oversized for Appli...

Страница 14: ...eceived by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a s...

Отзывы: