background image

* Switchable. Switch is internally-mounted for security.

** Rating shown is for operation at maximum ambient temperature.

"

115V, 60 Hz and 230V, 60 Hz models also perform at full capacity when operated

at 100V, 50 Hz or 200V, 50 Hz respectively.  No transformer is required.

G

KA4C1P_ _L

1000

120/50

115/100

60/50

14.2

90

90

110

G

KA4C1P_ _L56

1000

120/50

115

50/60*

14.2

90

90

110

G

K2A4C1P_ _L

1000

125/50

230/200

60/50

6.2

90

90

110

G

K2A4C1P_ _L5

1000

125/50

230

50

6.2

90

90

110

G

KA4C2P_ _L

2000

120/50

115/100

60/50

14.2

90

90

110

G

G

KA4C2P_ _L

2000

125/50

115/100

60/50

12.0

90

90

110

G

KA4C2P_ _L56

2000

120/50

115

50/60*

14.2

90

90

110

G

G

KA4C2P_ _L56

2000

120/50

115

50/60*

12.5/12.0

90

90

110

G

K2A4C2P_ _L

2000

125/50

230/200

60/50

6.2

90

90

110

G

G

K2A4C2P_ _L

2000

125/50

230/200

60/50

5.9/5.8

90

90

110

G

K2A4C2P_ _L5

2000

125/50

230

50

6.2

90

90

110

G

G

K2A4C2P_ _L5

2000

125/50

230

50

6.0

90

90

110

G

KA4C3P_ _L

3000

120/50

115/100

60/50

14.2

90

90

110

G

G

KA4C3P_ _L

3000

125/50

115/100

60/50

12.0

90

90

110

G

KA4C3P_ _L56

3000

120/50

115

50/60*

14.2

90

90

110

G

G

KA4C3P_ _L56

3000

120/50

115

50/60*

12.5/12.0

90

90

110

G

K2A4C3P_ _L

3000

125/50

230/200

60/50

6.2

90

90

110

G

G

K2A4C3P_ _L

3000

125/50

230/200

60/50

5.9/5.8

90

90

110

G

K2A4C3P_ _L5

3000

125/50

230

50

6.2

90

90

110

G

G

K2A4C3P_ _L5

3000

125/50

230

50

6.0

90

90

110

G

KA4C4P_ _L

4000

120/50

115/100

60/50

14.2

90

90

110

G

G

KA4C4P_ _L

4000

125/50

115/100

60/50

12.0

90

90

110

G

KA4C4P_ _L56

4000

120/50

115

50/60*

14.2

90

90

110

G

G

KA4C4P_ _L56

4000

120/50

115

50/60*

12.5/12.0

90

90

110

G

K2A4C4P_ _L

4000

125/50

230/200

60/50

6.2

90

90

110

G

G

K2A4C4P_ _L

4000

125/50

230/200

60/50

5.9/5.8

90

90

110

G

K2A4C4P_ _L5

4000

125/50

230

50

6.2

90

90

110

G

G

K2A4C4P_ _L5

4000

125/50

230

50

6.0

90

90

110

G

KA4C5P_ _L

5000

120/50

115/100

60/50

14.2

90

90

110

G

G

KA4C5P_ _R

5000

125/50

115/100

60/50

17.6/19.8

90

90

110

G

KA4C5P_ _L56

5000

120/50

115

50/60*

14.2

90

90

110

G

G

KA4C5P_ _R56

5000

125/50

115

50/60*

17.6

90

90

110

G

G

K2A4C5P_ _L

5000

125/50

230/200

60/50

9.5/9.9

90

90

110

G

G

K2A4C5P_ _L5

5000

115/50

230

50

8.0

90

90

110

G

G

KA4C6P_ _R

6000

125/50

115/100

60/50

17.6/19.8

90

90

110

G

G

KA4C6P_ _R56

6000

125/50

115

50/60*

17.6

90

90

110

G

G

K2A4C6P_ _L

6000

125/50

230/200

60/50

9.5/9.9

90

90

110

G

G

K2A4C6P_ _L5

6000

115/50

230

50

8.0

90

90

110

G

G

KA4C7P_ _R

7000

125/50

115/100

60/50

17.6/19.8

90

90

110

G

G

KA4C7P_ _R56

7000

125/50

115

50/60*

17.6

90

90

110

G

G

K2A4C7P_ _L

7000

125/50

230/200

60/50

9.5/9.9

90

90

110

G

G

K2A4C7P_ _L5

7000

115/50

230

50

8.0

90

90

110

G

KA3C8P_ _R

8000

120/50

115/100

60/50

18.0/17.5

90

90

110

G

KA3C8P_ _R56

8000

115/50

115

50/60*

16.5/18.0

90

90

110

G

K2A3C8P_ _L

8000

115/50

230/200

60/50

9.5

90

90

110

G

K2A3C8P_ _L5

8000

120/50

230

50

7.9

90

90

110

Approx.

Series

**

Ambient

**

Weight

Height BTU/H

Temp. 

°F

Running

(lbs.)

24 28 36

Model

Rating

Max./Min.

Volts

Hz

Amps

24

28

36

Technical Data

"

"

9

Units in BOLD are current standard products. Other units are prior product offerings and shown for reference only.

Содержание P24 SERIES

Страница 1: ...ORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 www kooltronic com P24 SERIES P28 SERIES P36 SERI...

Страница 2: ...ntroduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all sizes and shapes of electronics enc...

Страница 3: ...e in a horizontal position only This placement must be done a minimum of 5 minutes prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operati...

Страница 4: ...ce matches these requirements Use of incorrect type or amount of refrigerant will adversely affect performance and may damage the unit Make sure that these parameters are met Failure to do so may resu...

Страница 5: ...by means of the vapor compression refrigeration cycle This takes place in a hermetically sealed refrigeration system utilizing either an air cooled or water cooled condenser heat exchanger The warm ai...

Страница 6: ...blower will be delayed until the system pressures rise 10 Operate the air conditioner for approximately ten 10 minutes During this period no unusual noise or vibration should be evident Both the evapo...

Страница 7: ...densate Evaporator The drain hoses fittings and Condensate Evaporator must be removed before dismounting the Air Conditioner as they will not support the weight of the Air Conditioner unit The externa...

Страница 8: ...ing should be located as high as possible within this area and equal or exceed size of cool air outlets FILTERED CONDENSER AIR INLET Ambient Air In CONDENSER OUTLET Warm Ambient Air Out COOL AIR OUTLE...

Страница 9: ...00 125 50 115 100 60 50 12 0 90 90 110 G KA4C4P_ _L56 4000 120 50 115 50 60 14 2 90 90 110 G G KA4C4P_ _L56 4000 120 50 115 50 60 12 5 12 0 90 90 110 G K2A4C4P_ _L 4000 125 50 230 200 60 50 6 2 90 90...

Страница 10: ...AL CAP 1 3 EVAP BLOWER MOTOR 0 1 4 8 2 6 CRANKCASE HEATER MOTOR BLOWER COND TIMER CYCLE SHORT PRESSURE SWITCH OPTIONAL RELAY RELAY S L 2 1 M CAP WE BK RED ALARM SYSTEM TO CUSTOMER BLOCK TERMINAL EXCES...

Страница 11: ...Continued operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service Kooltronic Air Conditioners feature an easily removable inlet f...

Страница 12: ...valve fails it is strongly recommended that the Air Conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect refri...

Страница 13: ...ntrol Replace Thermostat or Relay Thermostat defective when applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit Contact Kooltronic Oversized for Appli...

Страница 14: ...unted Cooled Mini NP33 Horizontal Accessories and Options HS P24 P47 NP36 Rack Top Panel MM NM P28 P52 NP47 Mounted Mounted Mounted SM NP17 P36 P59 NP59 H V HT WP Adapter Plate for Rack Mounting N A N...

Страница 15: ...riginal customer Purchase Order number and date Date product was received by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Cont...

Отзывы: