7
VII. Specific Model Data
Mounting
Kooltronic Air Conditioners have been engineered to be installed easily. To avoid damaging your Air
Conditioner, please read the following information before installation:
Air Conditioner, please read the following information before installation:
1.
Loosen the four screws holding the Mounting Template and Assembly Bracket (M/TAB) to the unit.
Remove the M/TAB.
2.
See Figure 1 for proper orientation. Place the M/TAB flush against the outside of the cabinet to locate
cutouts and mounting holes.
3.
NOTE: The top cutout for the warm air return does not have to match the full 7" opening on the M/TAB.
You can locate your cutout anywhere within this opening. Locate your cutout close to the top and not
less than 3" high.
Make sure the cutouts don't interfere with components inside your cabinet.
4.
Mount the M/TAB to the outside of the cabinet using all the mounting hardware supplied by Kooltronic
(
1/4
-20 screws/nuts/washers). Preferred positions: one in each corner and two near center on each side.
NOTE: Make sure the screws are inserted with heads toward you. Tighten nuts securely.
5.
Route the power cord through the top cut out in your cabinet. Mount the unit to the M/TAB by sliding
the 4 studs on the side panel into the 4 slots on the M/TAB. After unit is in place, tighten 2 screws
at bottom of unit. These two screws will force the M/TAB into studs on side panel for a tight seal.
6.
Attach overflow drain hose supplied to the drain exit at the bottom of the unit. This hose must not be
elevated above the exit port. Improper mounting will impede the flow of condensate and may cause
internal malfunctions.
CAUTION
If the Air Conditioner is mounted to the cabinet door you must be sure
that the door hinges will support the additional weight of the Air
Conditioner. Also be certain that when the door is opened fully, the
cabinet does not become unbalanced. The actual weight of the unit can
be found in the Technical Data on page 9.
10.14
[257.6]
28.50
[723.9]
11.50
[292.1]
DRAIN
HIGH PRESSURE
RESET SWITCH
POWER CORD
WATER INLET
WATER OUTLET
1
1
2
8.00
[203.2]
7.00
[177.8]
1.07
[27.2]
2.39
[60.6]
7.50
[190.5]
TYP.
(8) .250 [6.4]
DIA. HOLES
7.00
[177.8]
4.30
[109.2]
7.75
[196.8]
1.57
[39.9]
2.92
[74.2]
1.57
[39.9]
1.50
[38.1]
7.75
[196.8]
2.76
[70.2]
3.41
[86.7]
4.18
[106.3]
M/TAB
SUPPLY
AIR OUT
RETUR
N
AIR I
N
RETUR
N
AIR I
N
FIGURE 1
WNP28 SERIES
WARM AIR RETURN FROM
ENCLOSURE
COOL AIR OUTLET
TO ENCLOSURE
1
2
Dimensions (inches) are for reference only and are subject to change.
MOUNTING PLAN