background image

7

VII. Specific Model Data

Mounting

Kooltronic Air Conditioners have been engineered to be installed easily. To avoid damaging your Air
Conditioner, please read the following information before installation:

Air Conditioner, please read the following information before installation:

1.

Loosen the four screws holding the Mounting Template and Assembly Bracket (M/TAB) to the unit.
Remove the M/TAB.

2.

See Figure 1 for proper orientation. Place the M/TAB flush against the outside of the cabinet to locate
cutouts and mounting holes.

3.

NOTE: The top cutout for the warm air return does not have to match the full 7" opening on the M/TAB.
You can locate your cutout anywhere within this opening. Locate your cutout close to the top and not
less than 3" high. 

Make sure the cutouts don't interfere with components inside your cabinet.

4.

Mount the M/TAB to the outside of the cabinet using all the mounting hardware supplied by Kooltronic
(

1/4

-20 screws/nuts/washers). Preferred positions: one in each corner and two near center on each side.

NOTE: Make sure the screws are inserted with heads toward you. Tighten nuts securely.

5.

Route the power cord through the top cut out in your cabinet. Mount the unit to the M/TAB by sliding
the 4 studs on the side panel into the 4 slots on the M/TAB. After unit is in place, tighten 2 screws
at bottom of unit. These two screws will force the M/TAB into studs on side panel for a tight seal. 

6.

Attach overflow drain hose supplied to the drain exit at the bottom of the unit.  This hose must not be
elevated above the exit port. Improper mounting will impede the flow of condensate and may cause
internal malfunctions.

CAUTION

If the Air Conditioner is mounted to the cabinet door you must be sure

that the door hinges will support the additional weight of the Air

Conditioner. Also be certain that when the door is opened fully, the

cabinet does not become unbalanced. The actual weight of the unit can

be found in the Technical Data on page 9.

 10.14

 [257.6]

 28.50

 [723.9]

 11.50

 [292.1]

DRAIN

HIGH PRESSURE
RESET SWITCH

POWER CORD

WATER INLET

WATER OUTLET

1

1

2

 8.00

 [203.2]

 7.00

 [177.8]

 1.07

 [27.2]

 

 2.39

 [60.6]

 

  7.50

  [190.5]

   TYP.

 (8) .250 [6.4]

 DIA. HOLES

 7.00

 [177.8]

 4.30

 [109.2]

  7.75

  [196.8]

  1.57

  [39.9]

  2.92

  [74.2]

  1.57

  [39.9]

  1.50

  [38.1]

  7.75

  [196.8]

  2.76

  [70.2]

  3.41

  [86.7]

  4.18

  [106.3]

 M/TAB

SUPPLY 
AIR OUT

 

RETUR

N

 

AIR I

N

 

RETUR

N

 

AIR I

N

 

FIGURE 1

WNP28 SERIES

WARM AIR RETURN FROM
ENCLOSURE

COOL AIR OUTLET 
TO ENCLOSURE

1

2

Dimensions (inches) are for reference only and are subject to change.

MOUNTING PLAN

Содержание K2A4C2WNP28

Страница 1: ...S IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 www kooltronic com TRIMLINE WNP28 SERIES 900...

Страница 2: ...age of the Kooltronic website I Introduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all si...

Страница 3: ...prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operating this unit all electrical wiring must be checked to assure the proper connection...

Страница 4: ...Final Assy Number MFG Order Number e Before operating be sure that the power source matches these requirements y Use of incorrect type or amount of refrigerant will adversely affect performance and ma...

Страница 5: ...ession refrigeration cycle This takes place in a hermetically sealed refrigeration system utilizing either an air cooled or water cooled condenser heat exchanger The warm air inside the enclosure is d...

Страница 6: ...blower will be delayed until the system pressures rise 10 Operate the air conditioner for approximately ten 10 minutes During this period no unusual noise or vibration should be evident Both the evap...

Страница 7: ...e top cut out in your cabinet Mount the unit to the M TAB by sliding the 4 studs on the side panel into the 4 slots on the M TAB After unit is in place tighten 2 screws at bottom of unit These two scr...

Страница 8: ...ATER INLET 3 8 18 NPT MALE FITTING DRAIN 63 16 1 4 01 101 9 28 50 723 9 THERMOSTAT ADJUSTMENT 1 1 2 Drawings and Dimensions WNP28 SERIES Other drain outlets are available contact KOOLTRONIC Dimensions...

Страница 9: ...ater temperature 115V 60 Hz and 230V 60 Hz models also perform at full capacity when operated at 100V 50 Hz or 200V 50 Hz respectively No transformer is required KA4C2WNP28 2000 1 0 115 100 60 50 13 0...

Страница 10: ...nd the compressor will continue to cycle on and off Continued operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service Kooltronic A...

Страница 11: ...ypass valve fails it is strongly recommended that the Air Conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect...

Страница 12: ...applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit Contact Kooltronic Oversized for Application Failed Evaporator Blower Replace Evaporator Blower Mo...

Страница 13: ...nal customer Purchase Order number and date Date product was received by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact...