background image

Keep This  Manual

With Air Conditioner

AIR CONDITIONER

OPERATOR'S MANUAL

CAUTION

BEFORE INSTALLING AND

USING THIS AIR CONDITIONER,

IT IS IMPORTANT THAT THIS

MANUAL BE READ AND

UNDERSTOOD THOROUGHLY

KOOLTRONIC, INC.

30 Pennington-Hopewell Road

Pennington, NJ 08534

609 • 466-3400

FAX: 609 • 466-1114

www.kooltronic.com

900-039-38 (2/19)
(CDR: 20131)

ADVANTAGE

RP55 SERIES

Find additional information on
this model at kooltronic.com or
use the Technical Documents
QR code below.

Technical

Documents

Содержание Advantage RP55 Series

Страница 1: ...TANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 www kooltronic com 900 039 38 2 19 CDR 20131 ADVANT...

Страница 2: ...tion Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all sizes and shapes of electronic enclosures...

Страница 3: ...e in a horizontal position only This placement must be done a minimum of 5 minutes prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operati...

Страница 4: ...Use of incorrect type or amount of refrigerant will adversely affect performance and may damage the unit r Make sure that these parameters are met Failure to do so may result in permanent damage to t...

Страница 5: ...hen passed through the condenser coil where it absorbs the heat and is then discharged to the environment The unit is equipped with a Bypass Thermostat to prevent the evaporator coil from freezing and...

Страница 6: ...r respective discharge ports The cool air discharged should be less than 70 F when the room temperature is between 70 F and 80 F 10 Turn off the electrical power and disconnect the air conditioner fro...

Страница 7: ...e front panel on the hooks of the M TAB Using the two hooks on each side of the M TAB as a guide be sure that the air conditioner is absolutely parallel to the M TAB We recommend using a lift truck fo...

Страница 8: ...1 25 31 7 0 74 18 7 19 25 488 9 1 00 31 44 798 5 10 00 1 36 34 5 18 00 457 2 25 4 53 35 1355 0 20 64 524 2 7 31 185 6 TYP LEFT FRONT RIGHT REAR BOTTOM TOP 254 0 10 00 254 0 0 69 17 5 6 00 15 2 21 99...

Страница 9: ...P55R Part Part Number Compressor 0665 78 Compressor Capacitor 0452 61 Condenser Blower Motor 0261 138 Condenser Blower Capacitor 0452 44 Evaporator Blower Motor 0261 288 Evaporator Blower Capacitor 04...

Страница 10: ...OTOR CAP BK WE CRANKCASE HEATER PRESSURE SWITCH N O COOLING EFFECT DETECTOR TERMINAL BLOCK TO CUSTOMER ALARM SYSTEM RELAY 1 R CONTROL Y B T STAT HEATER HEATER B C T STAT CUT OUT THERMAL TRANSFORMER DI...

Страница 11: ...operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service Kooltronic Air Conditioners feature an easily removable inlet filter to fa...

Страница 12: ...ss valve fails it is strongly recommended that the air conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect ref...

Страница 13: ...applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit Contact Kooltronic Oversized for Application Failed Evaporator Blower Replace Evaporator Blower Mo...

Страница 14: ...eceived by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a s...

Отзывы: