~10~
~11~
SAFETY FEATURES:
ALARM:
=
If the temperature exceeds 72º F the unit will shut down; a sound warning will start, and the display
will blink alternating with the temperature reading.
=
This function is disabled in the first 4 hours “ Cool Down” period or after any reset for another 4 hours.
=
The unit will restart and continue the cooling and cycling if the temperature falls below 72º F.
TO RESET:
=
Unplug, wait 5 seconds and re plug the unit.
OVERFLOW:
=
If the condensate pan is filled due to excessive humidity the unit stops, and warns with a buzzer and the
"CUP FULL" message on the display.
TO RESET: Empty cup located under the cooling unit.
AL
CONTROLS : PLUG IT IN
(wait one minute)
and ENJOY!
KEYS
DISPLAY:
=
Default SET temperature 57º F/14º C (ideal for wine storage).
=
Calibration option of the temperature sensor.
=
SET temperature range 52ºF-72ºF.
=
Digital temperature sensor.
=
Dual display Fº/Cº.
=
Magnetic overflow sensor.
=
Settings are stored in memory for power failures.
=
Pre programmed software will reach the quietest most efficient operation.
FEATURES:
OPERATION:
=
The display will show the detected temperature until the temperature falls within 3º of the SET POINT.
=
If the temperature is above the default 57º F + 1º or other preset value, after a
delay of 1 minute
the fan
will start after a delay of one minute, followed by the compressor within the next minute.
=
The unit will cycle ON/OFF based on the temperature reading. Fan speeds are automatically set by the
controller to achieve optimum performance.
=
Minimum ON and OFF cycle times are imposed by software, to prevent “short cycling”.
CONTROLLER
OPERATION
ACTION
DISPLAY EXAMPLE
BEFORE
AFTER
TO MODIFY THE SET
TEMPERATURE
(range is 52-72
ºF)
:
PRESS and RELEASE
57
º
57
º
To increase:
PRESS once per degree
57
º
58
º
To decrease:
PRESS once per degree
57
º
56
º
The new value will be memorized and the controller will
reset automatically.
TO CHANGE FROM
ºF to ºC or
ºC to ºF:
PRESS and HOLD until buzzer sounds in 5 seconds
57
º
14
º
The new value will be memorized and the controller will
reset automatically.
TO CALIBRATE:
HOLD DOWN KEY, PRESS and RELEASE BOTH.
57
º
57
º
Wait 5 seconds
57
º
F0
USE or
F0
F1
for each degree of offset
F0
-1
TO DISPLAY CURRENT
TEMP. OF SENSOR:
PRESS and HOLD to display, Release to get out.
NOTE:
A negative offset will result in a warmer cabinet and a positive offset will result in a cooler cabinet.