4.2 In accepting the goods, please carefully check everything according to the attached

packing list to figure out damages, if any. In case of any damage detected, please contact us

through phone or fax immediately, and we will respond to the situation as soon as possible.

4.3 In case of any damage or loss, please identify the situation in the packing list and have the

consigner acknowledge it with signature before returning it to us.

5

Installation

5.1 The product should be place on a solid and flat floor with no gradient.

5.2 The product is recommended to work with under 28

ambient temperature and less

than 55% relative humidity, where direct sunshine and draught can be avoided. Additionally,

disturbing air devices such as fan or air conditioner vent should be appear from its top or nearby.

5.3 Unobstructed ventilation should be ensured for condensing unit with ample room for

repairing.

5.4 The melting water can be directed into the sewer near the product, if any, or otherwise

evaporated through electric heating.

6

Normal operation

6.1 Full-automation. Fully consider the local seasonal conditions within a year and the

surrounding environment are sufficiently considered during the setting of control modules, to

ensure the optimal operation of the whole full-automatic product.

6.2 Normal cooling. Set the temperature controller properly according to customers’ needs to

achieve both energy-saving and normal cooling. See the Appendix: Instruction of CAREL

Temperature Controller for details.

6.3 Normal melting. Set the timer properly for melting time and interval according to the

ambient temperature and humidity, with over two melting periods for verification. See the

Appendix: Instruction of CAREL Temperature Controller for details.

6.4 Have the customer sign Debugging Record and Installation Acceptance Report before

finishing the consignment.

6.5 During normal operation, the storage should not be placed beyond the shelf or block the

return air from the air curtain.

7

Maintenance and notes

7.1 Cabinet cleaning. The product should be cleaned once a week with power supply

disconnected. In cleaning, please use mild rinsing water or non-corrosive cleanser essence. Do

not wash it directly with water faucet.

7.2 De-dusting for condenser. The condenser should be cleaned every three months with

power supply disconnected. To clean the condenser, remove the left panel, and remove the dust

on the cooling fin of the condenser with wire brush or high pressure air gun.

7.3 Leaking check. Observe all connectors and welding joints for oil stain, which indicates a