Part Number STH063 9/17
51
Ice Machine Cycles Into Harvest Before Water
Loses Contact with the Harvest Float Switch
Step 1
Disconnect power to the ice machine, remove
the electrical panel to allow viewing of the control board
lights and disconnect the harvest float switch from the
control board.
HARVEST FLOAT SWITCH
ICE THICKNESS FLOAT
SWITCH
Step 2
Reapply power and move the toggle switch to
Ice to bypass the freeze time lock-in feature. Wait until
water flows over the evaporator, then refer to chart.
Result
Correction
The harvest light does not come
on and the ice machine stays
in freeze.
The ice thickness float switch,
connectors or wiring are
causing the malfunction. Refer
to float switch diagnostics.
10 seconds into the freeze
cycle the ice machine cycles
from freeze to harvest and
the control board harvest light
energizes.
Replace the control board.
Содержание KDT0300A
Страница 1: ...Part Number STH063 9 17 Koolaire KT Model Ice Machines Technician s Handbook ...
Страница 2: ......
Страница 26: ...26 Part Number STH063 9 17 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 46: ...46 Part Number STH063 9 17 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 114: ...114 Part Number STH063 9 17 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 146: ...146 Part Number STH063 9 17 ELECTRONIC CONTROL BOARD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 18 20 21 23 24 25 22 ...
Страница 150: ...150 Part Number STH063 9 17 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 151: ......