BAKL6U022AA 

Edition: 28.02.2017

 

Page: 4/9 

 

Information on the operating instructions 

These operating instructions are valid fort he air conditioners type: 

 

UL500 

 

UL700 

 

UL800 

With Wabco control system 

 

When taking the unit into operation we recommend adding the following data. 

This will also be important for your orders of spare parts, and in case of warranty

 

Serial number of the unit: 

 ......................................................  

 

 

Order No.: 

 ......................................................  

 

 

Year of construction:

 

 ......................................................   

(MM/YY)

 

 

 

Date of first operation:

 

 ......................................................   

(

DD/

MM/YY)

 

The machine is in accordance with the EC machinery directive 2006/42/EC. 

The unit contains or needs fluorinated greenhouse gas for operation and is subject 
to identification requirements in accordance with F-Gas Regulation 517/2014.

 

Due to the fact that scope of supply depends on the order, equipment of your product may 
differ in some parts of description. 
In case your product is equipped with details not shown or described in the operating in-
struction,  your  KONVEKTA  -Service-Station  will  always  be  at  disposal  for  informing  you 
about correct operation. 

In the course of further developments we reserve the right to technical modifications without no-
tice. Guarantee and liability conditions of 

KONVEKTA  AG

’s general business conditions are not 

enlarged

 

by the above notes. 

Indications and photos should neither be copied and circulated nor used for competitor’s purpos-
es. All rights according to the copyright remain expressly reserved. 

Manufacturer: KONVEKTA AG, P.O.Box 2280, D-34607 Schwalmstadt

 

1.  Technical data 

1.1. 

Air conditioner 

Type 

 

UL 500 

UL 700

 

UL 800

 

Refrigerant 

 

R 134a 

GWP 

 

1.430 

Refrigerant quantity ca. 

kg 

8,5 

9,5 

10,5 

Operating voltage 

Volt DC 

26 

26  

26  

Power consumption 

72 

104 

136 

Cooling capacity 

24.000 

33.000 

39.000 

Evaporator – air volume 

m

3

/h 

4.320 

6.480  

8.640 

 

Содержание UL500

Страница 1: ...chwalmstadt Germany 49 0 66 91 76 0 49 0 66 91 76 200 Info konvekta com www konvekta com Operating Instructions for KONVEKTA Air Conditioning units UL500 UL700 UL800 with Wabco control system R134a 24 Volt DC ID BBA KL6U022AA Version A03 ...

Страница 2: ...ction of the keys 6 3 1 1 Flap for windshield floor 6 3 1 2 Desired value of front box temperature 6 3 1 3 Blower speed 6 3 1 4 Smog 6 3 1 5 Heater passenger s compartment 7 3 1 6 Additional heater 7 3 1 7 Reheat 7 3 1 8 Driver s seat air conditioning 7 3 1 9 General 7 4 Wartung 7 4 1 Troubleshooting 8 5 Warranty Conditions 8 6 Waste disposal in accordance with legal provisions 9 7 History of modi...

Страница 3: ...increases operation reliability and service life of the air conditioning unit and reduces life cycle costs Please complete these instructions by adding the national provi sions for prevention of accidents and environmental protection These instructions are part of the air conditioning unit Always have a copy at hand in the driver s cabin You will certainly understand that we will not recognize any...

Страница 4: ...t may differ in some parts of description In case your product is equipped with details not shown or described in the operating in struction your KONVEKTA Service Station will always be at disposal for informing you about correct operation In the course of further developments we reserve the right to technical modifications without no tice Guarantee and liability conditions of KONVEKTA AG s genera...

Страница 5: ... and aluminium components cannot be ruled out The cupper and aluminium components of the KONVEKTA systems are not suitable for such extreme application conditions We indicate emphatically that corrosion is not subject to warranties for defects KONVEKTA does not take over any warranties for defect neither for corrosion nor for consequential damage resulting there from nor for damages caused by clea...

Страница 6: ...osition Air circulation is split up between floor and windshield Arrow up flap for windshield The whole air is lead to the windshield Symbol windshield defrost Water valve completely opened air to windshield max imal blower speed The conversion is realized via characteristic curves which also facilitate intermediate positions 3 1 2 Desired value of front box temperature The blowout temperature of ...

Страница 7: ...nce works we refer to our maintenance instructions BWA KL6U022AA which have been written exclusively for maintenance personal Please arrange regular dates for maintenance works and services with a KONVEKTA service station as indicated in maintenance schedule bus no WP07050618 Only qualified staff is allowed to carry out these works For general instructions on repair and maintenance works please co...

Страница 8: ... magnetic clutch compressor does not compress check high and low pressure replace com pressor if necessary excess pressure pressure too high check axial fans check fuses at switchboard clean condenser coil with compressed air excess pressure caused by high out side temperature run unit until pressure has stabilized leakage in a c unit lack of refrigerant check a c unit for leakages refill refriger...

Страница 9: ...of the Council for ma terials that affect the ozone layer Resolution to prohibit certain ozone destroy ing halogen hydrocarbons The used refrigerant endangers the environment When dealing with refrigerants the existing pre scriptions and regulations are to be followed Only qualified staff is allowed to carry out these works Water endangering substances acc to 19g 19l are solid liquid and gaseous s...

Отзывы: