BAKL6U022AA
Edition: 28.02.2017
Page: 4/9
Information on the operating instructions
These operating instructions are valid fort he air conditioners type:
UL500
UL700
UL800
With Wabco control system
When taking the unit into operation we recommend adding the following data.
This will also be important for your orders of spare parts, and in case of warranty
.
Serial number of the unit:
......................................................
Order No.:
......................................................
Year of construction:
......................................................
(MM/YY)
Date of first operation:
......................................................
(
DD/
MM/YY)
The machine is in accordance with the EC machinery directive 2006/42/EC.
The unit contains or needs fluorinated greenhouse gas for operation and is subject
to identification requirements in accordance with F-Gas Regulation 517/2014.
Due to the fact that scope of supply depends on the order, equipment of your product may
differ in some parts of description.
In case your product is equipped with details not shown or described in the operating in-
struction, your KONVEKTA -Service-Station will always be at disposal for informing you
about correct operation.
In the course of further developments we reserve the right to technical modifications without no-
tice. Guarantee and liability conditions of
KONVEKTA AG
’s general business conditions are not
enlarged
by the above notes.
Indications and photos should neither be copied and circulated nor used for competitor’s purpos-
es. All rights according to the copyright remain expressly reserved.
Manufacturer: KONVEKTA AG, P.O.Box 2280, D-34607 Schwalmstadt
1. Technical data
1.1.
Air conditioner
Type
UL 500
UL 700
UL 800
Refrigerant
R 134a
GWP
1.430
Refrigerant quantity ca.
kg
8,5
9,5
10,5
Operating voltage
Volt DC
26
26
26
Power consumption
A
72
104
136
Cooling capacity
W
24.000
33.000
39.000
Evaporator – air volume
m
3
/h
4.320
6.480
8.640