5.  Maintenance / Servicing 

Please arrange regular dates for maintenance works and services with a KONVEKTA service sta-
tion, as indicated in maintenance schedule bus no. 

WP07050618

- Only qualified staff is allowed to carry out these works! - 

For general instructions on repair – and maintenance works please contact via email: 

[email protected]

 

 

Danger of accidents! 

Qualified  staff in  charge  of  installation  and maintenance  have  to  be  trained in  accordance 
with EN 378-Part 4 and (EG) No.307 / 2008 and must strictly follow the legal provisions.

 

Any works or modifications at the air conditioner which are carried out improperly can lead 
to malfunction and so endanger operational reliability. We recommend having all works and 
modifications carried out at an authorized KONVEKTA Service Station

.  

Before carrying out any maintenance works at your air conditioning unit, carefully read the  
KONVKETA safety provisions (TD00052A )

 

in order to avoid any dangers and accidents! 

 

On our website www.konvekta.com in category >service< you will find a survey of contact details of all our 

service partners close to your location 

 

Source of supply: 

KONVEKTA AG

, P.O. Box 2280, D-34607 Schwalmstadt

 

5.1.  Compressor 

Regard the oil amounts for each type of compressor (refer to „technical data on the compressor“) 

5.2.  Circulation air grid 

See service plan bus no: WP 07 05 06 18 / point WK13: 
The circulation air grid in the passenger area should be cleaned every month; or weekly if major 
amounts of dirt are present. 

5.3.  Condenser battery 

See service plan bus no: WP 07 05 06 18 / point WK03: 
Regular cleaning (blowing with compressed air) should be undertaken 

annually

; more often if ma-

jor amounts of dirt are present. 

 

Note: 

Attention should be paid to the cleanliness of the blades on the condenser. If these are very dirty, 

the result is high pressure in the conditioning system and the air-conditioning unit switches itself 
off

Содержание KL30/12V

Страница 1: ...6 0 49 0 66 91 76 200 Info konvekta com www konvekta com Instruction manual for KONVEKTA air conditioning units KL30 KL30T With KK2 control Version 12 or 24 volt DC Circulating air Circulating air fresh air Circulating air fresh air heating ID BBA KL30T12AC Version A03 ...

Страница 2: ...3 Self test 7 4 4 Setting the required room temperature 7 4 5 Disturbance display temperature sensor error 8 4 6 Manual setting of the vaporiser fan speed 8 4 7 Outside temperature display 8 4 8 Switching between circulation air fresh air function 8 4 9 Convector heating 8 5 Maintenance Servicing 9 5 1 Compressor 9 5 2 Circulation air grid 9 5 3 Condenser battery 9 5 4 Troubleshooting 10 6 Warrant...

Страница 3: ...increases operation reliability and service life of the air conditioning unit and reduces life cycle costs Please complete these instructions by adding the national provisions for prevention of accidents and environmental protection These instructions are part of the air conditioning unit Always have a copy at hand in the driver s cabin You will certainly understand that we will not recognize any ...

Страница 4: ...uct is equipped with details not shown or described in the operating in struction your KONVEKTA Service Station will always be at disposal for informing you about correct operation In the course of further developments we reserve the right to technical modifications without preno tice Guarantee and liability conditions of KONVEKTA AG s general business conditions are not enlarged by the above note...

Страница 5: ...ating fresh air kg ca 46 48 With standard ventilators and or fans 1 1 Pressure switches Bar OFF Bar ON Low pressure switch LP 2 0 2 2 1 0 3 High pressure switch HP 25 1 5 18 3 0 1 2 Compressor Important In order to avoid leaks on the shaft seal of the compressor The compressor must be switched on for approx 15 minutes every four weeks This includes when the vehicle is not used for a longer period ...

Страница 6: ...t a KONVEKTA Service Station Only after that you can take unit into operation On our website www konvekta com in category service you will find a survey of contact details of all our service partners close to your location 3 1 Operating conditions NOTE KONVEKTA uses components made of copper and aluminium which last a whole unit life time under normal environmental conditions Should the units be o...

Страница 7: ... shows the current room temperature in the normal status 4 3 Self test If the vehicle s ignition is turned but the engine has not been started up the control unit tests itself before the switch outputs on the control unit are released If errors are not present the room temperature is displayed 4 4 Setting the required room temperature Conditioning function is switched on automatic air conditioning...

Страница 8: ... activated Led 9 illuminates vaporiser fan level 2 is activated Led 10 illuminates vaporiser fan level 1 2 are activated Level 3 level 1 level 2 4 7 Outside temperature display Press simultaneously Display shows outside temperature 4 8 Switching between circulation air fresh air function Light diode illuminates fresh air function is switched on Light diode is not illuminated fresh air function is ...

Страница 9: ...works at your air conditioning unit carefully read the KONVKETA safety provisions TD00052A in order to avoid any dangers and accidents On our website www konvekta com in category service you will find a survey of contact details of all our service partners close to your location Source of supply KONVEKTA AG P O Box 2280 D 34607 Schwalmstadt 5 1 Compressor Regard the oil amounts for each type of co...

Страница 10: ...nd pressure points the compressor may need to be re placed excess pressure pressure too high Check if the ring fans are running Check the safety automatic on the panel and press in Clean the condenser blades High pressure due to high outside temperature Let the unit run until the pressure is stabi lised1 Leak in the unit lack of coolant Check unit for leaks Refill coolant Drier is blocked low pres...

Страница 11: ...that affect the ozone layer Law of chemicals 27 penal prescrip tions Resolution to prohibit certain ozone destroying halogen hydrocarbons The used refrigerant endangers the environment When dealing with refrigerants the existing pre scriptions and regulations are to be followed Only qualified staff is allowed to carry out these works Water endangering substances acc to 19g 19l are solid liquid and...

Отзывы: