![KONVEKTA KL30/12V Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/konvekta/kl30-12v/kl30-12v_instruction-manual_1996667007.webp)
BAKL30T12AC
Edition: 02.03.2017
Page: 7/11
press
press
Display returns to the current room temperature.
The operation of the air-conditioning unit takes place by using the KK2 control.
4.1. Front view of the controls
Key Function
1
No function
2
Key to switch the cooling function on and off
3
2-digit seven-segment display to show the desired room temperature.
Alternative: fault display, outside temperature
4
Key to set the desired room temperature higher
5
Key to set the desired room temperature lower
6
Switch key for vaporiser fan speed
7
Key to switch to circulation air function.
4.2. Temperature display
The display shows the current room temperature in the normal status.
4.3. Self-test
If the vehicle’s ignition is turned but the engine has not been started up, the control unit
tests itself before the switch outputs on the control unit are released.
If errors are not present, the room temperature is displayed.
4.4. Setting the required room temperature
Conditioning function is switched on (automatic air-conditioning (heat-
ing/cooling) is on.
Increase the target room temperature.
Reduce the target room temperature.
•
The conditioning function works with a tolerance range of ± 1.5°C
•
Cooling function: vaporiser fan level 1 is running automatically.
•
Heating function: vaporiser fan level 1 is not running.
•
Condenser fan has 20sec pre/post-run in comparison to the magnet clutch.
•
The conditioning output is blocked at an outside temperature of
5°C.