BAKL30T12AC 

Edition: 02.03.2017

 

Page: 7/11

 

 

 

 

  

  

  

  

press 

  

  

  

  

press

    

 

Display returns to the current room temperature. 

 

The operation of the air-conditioning unit takes place by using the KK2 control.  

4.1.  Front view of the controls 

 
 
 
 
 
 
 
 
 

Key  Function

 

No function 

Key to switch the cooling function on and off 

2-digit seven-segment display to show the desired room temperature. 
Alternative: fault display, outside temperature  

Key to set the desired room temperature higher 

Key to set the desired room temperature lower 

Switch key for vaporiser fan speed 

Key to switch to circulation air function. 

4.2.  Temperature display 

 

The display shows the current room temperature in the normal status. 
 

4.3.  Self-test 

If the vehicle’s ignition is turned but the engine has not been started up, the control unit 
tests itself before the switch outputs on the control unit are released. 
If errors are not present, the room temperature is displayed. 
 
 

4.4.  Setting the required room temperature 

Conditioning function is switched on (automatic air-conditioning (heat-
ing/cooling) is on. 
 

 
Increase the target room temperature. 
 
 
Reduce the target room temperature. 
 

 

 

 

The conditioning function works with a tolerance range of ± 1.5°C 

 

Cooling function: vaporiser fan level 1 is running automatically. 

 

Heating function: vaporiser fan level 1 is not running. 

 

Condenser fan has 20sec pre/post-run in comparison to the magnet clutch. 

 

The conditioning output is blocked at an outside temperature of 

5°C.  

 

Содержание KL30/12V

Страница 1: ...6 0 49 0 66 91 76 200 Info konvekta com www konvekta com Instruction manual for KONVEKTA air conditioning units KL30 KL30T With KK2 control Version 12 or 24 volt DC Circulating air Circulating air fresh air Circulating air fresh air heating ID BBA KL30T12AC Version A03 ...

Страница 2: ...3 Self test 7 4 4 Setting the required room temperature 7 4 5 Disturbance display temperature sensor error 8 4 6 Manual setting of the vaporiser fan speed 8 4 7 Outside temperature display 8 4 8 Switching between circulation air fresh air function 8 4 9 Convector heating 8 5 Maintenance Servicing 9 5 1 Compressor 9 5 2 Circulation air grid 9 5 3 Condenser battery 9 5 4 Troubleshooting 10 6 Warrant...

Страница 3: ...increases operation reliability and service life of the air conditioning unit and reduces life cycle costs Please complete these instructions by adding the national provisions for prevention of accidents and environmental protection These instructions are part of the air conditioning unit Always have a copy at hand in the driver s cabin You will certainly understand that we will not recognize any ...

Страница 4: ...uct is equipped with details not shown or described in the operating in struction your KONVEKTA Service Station will always be at disposal for informing you about correct operation In the course of further developments we reserve the right to technical modifications without preno tice Guarantee and liability conditions of KONVEKTA AG s general business conditions are not enlarged by the above note...

Страница 5: ...ating fresh air kg ca 46 48 With standard ventilators and or fans 1 1 Pressure switches Bar OFF Bar ON Low pressure switch LP 2 0 2 2 1 0 3 High pressure switch HP 25 1 5 18 3 0 1 2 Compressor Important In order to avoid leaks on the shaft seal of the compressor The compressor must be switched on for approx 15 minutes every four weeks This includes when the vehicle is not used for a longer period ...

Страница 6: ...t a KONVEKTA Service Station Only after that you can take unit into operation On our website www konvekta com in category service you will find a survey of contact details of all our service partners close to your location 3 1 Operating conditions NOTE KONVEKTA uses components made of copper and aluminium which last a whole unit life time under normal environmental conditions Should the units be o...

Страница 7: ... shows the current room temperature in the normal status 4 3 Self test If the vehicle s ignition is turned but the engine has not been started up the control unit tests itself before the switch outputs on the control unit are released If errors are not present the room temperature is displayed 4 4 Setting the required room temperature Conditioning function is switched on automatic air conditioning...

Страница 8: ... activated Led 9 illuminates vaporiser fan level 2 is activated Led 10 illuminates vaporiser fan level 1 2 are activated Level 3 level 1 level 2 4 7 Outside temperature display Press simultaneously Display shows outside temperature 4 8 Switching between circulation air fresh air function Light diode illuminates fresh air function is switched on Light diode is not illuminated fresh air function is ...

Страница 9: ...works at your air conditioning unit carefully read the KONVKETA safety provisions TD00052A in order to avoid any dangers and accidents On our website www konvekta com in category service you will find a survey of contact details of all our service partners close to your location Source of supply KONVEKTA AG P O Box 2280 D 34607 Schwalmstadt 5 1 Compressor Regard the oil amounts for each type of co...

Страница 10: ...nd pressure points the compressor may need to be re placed excess pressure pressure too high Check if the ring fans are running Check the safety automatic on the panel and press in Clean the condenser blades High pressure due to high outside temperature Let the unit run until the pressure is stabi lised1 Leak in the unit lack of coolant Check unit for leaks Refill coolant Drier is blocked low pres...

Страница 11: ...that affect the ozone layer Law of chemicals 27 penal prescrip tions Resolution to prohibit certain ozone destroying halogen hydrocarbons The used refrigerant endangers the environment When dealing with refrigerants the existing pre scriptions and regulations are to be followed Only qualified staff is allowed to carry out these works Water endangering substances acc to 19g 19l are solid liquid and...

Отзывы: