Kontron CU 5 -2 Series Скачать руководство пользователя страница 1



USER GUIDE

 

 
 

 

www.kontron.com 

 

 

 

 

Control Units CU 5x-2xxx 

Doc. Rev. 1.A    

Doc. ID: 90216 (EN)  

 

 

 

Содержание CU 5 -2 Series

Страница 1: ...USER GUIDE www kontron com Control Units CU 5x 2xxx Doc Rev 1 A Doc ID 90216 EN...

Страница 2: ...Control Units CU 5x 2xxx Rev 1 A www kontron com 2 This page has been intentionally left blank...

Страница 3: ...ation will be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general description of processes and instru...

Страница 4: ...ely at your risk To minimize the risks associated with your products and applications you should provide adequate design and operating safeguards You are solely responsible for compliance with all leg...

Страница 5: ...ontact information on the last page of this user guide or visit our website CONTACT US Customer Support Find Kontron contacts by visiting http www kontron com support Customer Service As a trusted tec...

Страница 6: ...scribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title inform that the electronic boards and their components are sensitiv...

Страница 7: ...rations on this product Therefore always unplug the power cable and any other cables which provide external voltages before performing any work on this product Earth ground connection to a central gro...

Страница 8: ...product then re pack it in the same manner as it was delivered Special care is necessary when handling or unpacking the product See Special Handling and Unpacking Instruction Quality and Environmental...

Страница 9: ...ower Management and Power Button 18 Thermal Management 19 RTC 19 Watchdog 19 Ethernet 19 3 2 Pin assignment base part 20 Power supply Connector X1 21 Ethernet connector X2 and X3 21 HDMI connector X7...

Страница 10: ...trol Unit 16 Table 4 Possible processors 17 Table 5 Status LEDs 18 Table 6 Power Management Energy States ACPI 18 Table 7 Power Button Function 19 Table 8 Signaling Ethernet Interface status 19 Table...

Страница 11: ...x 2xxx xxxxx determines the respective version For details on the product key see Appendix B The product versions in Table 1 are available as standard products Other versions are available on request...

Страница 12: ...x Profibus isol Operating system Microsoft Windows 10 IoT Enterprise license Linux Debian Software Soft SPS CODESYS Runtime system license Soft SPS CODESYS Target Visu license Soft SPS CODESYS Web Vis...

Страница 13: ...terface galv insulated on 4 pin Phoenix connector battery supported processor independent real time clock RTC processor independent Watchdog Timer Power Button 1x programmable status LED Power supply...

Страница 14: ...30 W The output of the power supply unit must meet the criteria of a safety extra low voltage SELV according to IEC 60664 1 The use of an unsuitable power supply unit can result in danger of electric...

Страница 15: ...ron de ueber uns corporate responsibility material declaration reach customer information 2 5 Type Label and Product Identification The type plate is located on the top side next to the heat sink of t...

Страница 16: ...Accessories for the Control Unit Article No Designation Comment 90215 Handbuch Control Unit CU 5x 2xxx Deutsches Handbuch 90196 System Manual Linux Deutsches Handbuch 90216 User Guide Control Unit CU...

Страница 17: ...tion Booting from USB LAN SD and eMMC Virtualization Intel VT x Built in UEFI Shell BIOS Password Execute Disable XD USB Support Fast Boot NOR Flash The NOR flash memory installed on the Control Unit...

Страница 18: ...atus LEDs next to the X1 Power connector Table 5 Status LEDs Designation Colour Meaning PWR Green Lights up permanently if 24V supply is available and the device is not in state G2 S5 see chapter 3 1...

Страница 19: ...temperature is used to throttle the clock rate and to shut down the operating system in case of overtemperature RTC The RTC RX 8564LC from Seiko Epson is used as clock component In combination with a...

Страница 20: ...5 mm for 24 VDC supply Power X2 RJ45 8P8C Connector for Ethernet Ethernet X3 RJ45 8P8C Connector for Ethernet Ethernet X4 2 port USB Host connector type A USB 2 0 X6 microSD Card Slot microSD X7 HDMI...

Страница 21: ...e with wire end ferrule 0 25 mm 1 5 mm Stripping length 10 mm The power cable must be rated for a temperature of 75 C or higher The cable can become damaged over time or potentially harmful plasticize...

Страница 22: ...cannot be guaranteed Kontron recommends the use of a certified Premium High Speed HDMI cable with the appropriate label from HDMI Licensing Administrator Inc Kontron is HDMI Adopter Version 1 4 and pa...

Страница 23: ...interface is internally terminated with a terminating resistor 120 CAN The electrically isolated interface CAN1 provides the signals CANL and CANH in CAN level The interface is connected to terminal...

Страница 24: ...2 2 EMC max 3 m shielded CAN Connector X9 1 Table 14 CAN Connector X9 1 Pin Signal Type Comment 1 SHIELD SHLD 2 CANH I O CAN Signal CAN_HIGH 3 CANL I O CAN Signal CAN_LOW 4 GND_CAN GND Cable acc to ch...

Страница 25: ...O RS485 Halfduplex TxRx 4 GND_RS485 GND Cable acc to chapter 2 2 EMC max 30 m shielded Mating connector e g Phoenix FMC 1 5 4 ST 3 5 1952283 Associated permissible cable cross sections Conductor cros...

Страница 26: ...Compliance with the prescribed EMC limit values can only be guaranteed if the device is properly grounded Damage to plugs or cables due to improper handling when plugging in and plugging out Material...

Страница 27: ...ure 6 A minimum distance of 10 cm must be maintained to other devices or objects on the DIN rail on both sides If necessary the distance must be increased if the installation regulations of the neighb...

Страница 28: ...y at the same time In this way Microsoft guarantees the secure use of its operating system for industrial customers without them being confronted with compatibility problems as in the past Linux Any L...

Страница 29: ...device descriptions and libraries for the CODESYS development environment The CODESYS Device Package can be ordered free of charge from Kontron Electronics AG at support kontron ch The CODESYS PLC ap...

Страница 30: ...vice via USB stick or SD card With a backup of the system the devices can be reset to a defined state or even cloned The backup restore function is integrated in the system configuration and can be ac...

Страница 31: ...d with the correct orientation as shown in the illustrations below Figure 7 Battery replacement Pull out the tab of the battery holder and thus the whole battery holder out of the device Remove the ol...

Страница 32: ...EU Battery Directive and Regulation EC No 1907 2006 REACH Recommended by Kontron Electronics AG are Renata Varta and Panasonic Batteries must not be disposed of with household waste and must not be in...

Страница 33: ...ge over HDMI Settings in BIOS are not correct Contact the support Interface function impaired Interface cable not plugged in correctly Check whether all interface cables are plugged in correctly and t...

Страница 34: ...e household waste and do not burn them Remove the backup battery from the device and dispose of it separately Kontron will gladly take back old electrical equipment at the end of its service life for...

Страница 35: ...Control Units CU 5x 2xxx Rev 1 A www kontron com 35 9 Technical drawings 9 1 Views and dimensions model CU 5x 251x mounting upright Figure 8 Views and dimensions model CU 5x 251x mounting upright...

Страница 36: ...Control Units CU 5x 2xxx Rev 1 A www kontron com 36 9 2 Views and dimensions model CU 5x 241x mounting flat Figure 9 Views and dimensions model CU 5x 241x mounting flat...

Страница 37: ...cle number or product ID number PN Production batch or Serial Number SN The numbers are located on a small label on the nameplate Be ready to explain the nature of your problem to the service technici...

Страница 38: ...information Download the RMA Request sheet for Kontron Europe GmbH and fill out the form Take care to include a short detailed description of the observed problem or failure and to include the produc...

Страница 39: ...ESD Electrostatic Discharge electrostatic discharge high electrical voltage pulse HDMI High Definition Multimedia Interface Interface for digital image sound transmission in consumer electronics subje...

Страница 40: ...method X DIN rail horizontal 4 DIN rail upright book form 5 3 Expansionboard X RS 232 RS 485 and CAN interface 1 Profibus and RS 485 interface 2 4 Temperature Range X Standard 0 C 55 C 0 5 RAM X 2GB 4...

Страница 41: ...Control Units CU 5x 2xxx Rev 1 A www kontron com 41 7 FRAM X 64kByte 4 128kByte 5 256kByte 6 512kByte 7 8 Ethernet X Not available 0 1 Port 1 2 Ports 2 9 HDMI X Not available 0 1 Port HDMI mini 1...

Страница 42: ...Control Units CU 5x 2xxx Rev 1 A www kontron com 42 This page has been intentionally left blank...

Страница 43: ...Control Units CU 5x 2xxx Rev 1 A www kontron com 43 This page has been intentionally left blank...

Страница 44: ...he art embedded technologies Kontron provides secure and innovative applications for a variety of industries As a result customers benefit from accelerated time to market reduced total cost of ownersh...

Отзывы: