The uEFI Shell
CP6004-SA/-RA/-RC/CP6004X-SA
Page 60
ID 1053-6161, Rev. 3.0
D R A F T — F O R I N T E R N A L U S E O N L Y
USAGE:
Set Serial-over-LAN I/O/SOL parameters:
COMMAND / RESPONSE EXAMPLE:
Shell> kipmi net 1
Display system event log:
COMMAND / RESPONSE EXAMPLE:
Shell> kipmi sel list
Show sensor related information:
COMMAND / RESPONSE EXAMPLE:
Shell> kipmi sensor list
Execute raw command. Example: Get self-test results.
COMMAND / RESPONSE EXAMPLE:
Shell> kipmi raw 0x06 0x00 0x04
Execute raw SendMessage command:
COMMAND / RESPONSE EXAMPLE:
Shell> kipmi rawsendmessage 0x20 0x00 0x06 0x00 0x01
SETTINGS:
fru [<Fru device ID>]:
Displays FRU data
Options:
Fru device ID:
Numeric FRU device ID. The FRU ID 0 is used by
default if no FRU ID is entered.
ipmb:
Displays IPMB bus settings
ipmb redundant:
Switch IPMB bus to redundant mode
ipmb single:
Switch IPMB bus to single mode
Note: The redundant mode is not available on the CP6004-SA/-RA/-RC/
CP6004X-SA. Please leave this function at single mode.
irq <number>:
Display/Set the IRQ number of the KCS interface
Options:
0:
KCS uses no IRQ
10:
KCS uses IRQ 10
11:
KCS uses IRQ 11
The board must be reset for the settings to apply.
mode <mode>:
Display/Set the IPMI controller operating mode
Options:
bmc:
IPMI controller operates in BMC mode (master)
smc:
IPMI controller operates in SMC mode (slave)
net:
Set IPMI-over-LAN (IOL) / Serial-over-LAN (SOL) parameters
sel:
Display system event log
kipmi (continued)