background image

The uEFI Shell

CP6004-SA/-RA/-RC/CP6004X-SA

Page 40

ID 1053-6161, Rev. 3.0

D R A F T   —   F O R   I N T E R N A L   U S E   O N L Y

This page has been intentionally left blank.

Содержание CP6004-RA

Страница 1: ...If it s embedded it s Kontron User Guide D R A F T F O R I N T E R N A L U S E O N L Y CP6004 SA CP6004 RA CP6004 RC CP6004X SA uEFI BIOS Doc ID 1053 6161 Rev 3 0 August 13 2013...

Страница 2: ...ot guaranteed for legal purposes Information has been carefully checked and is believed to be accurate however no responsibility is assumed for inaccuracies Kontron and the Kontron logo and all other...

Страница 3: ...1 TPM Support 10 2 2 1 2 TPM State 11 2 2 2 Pending TPM Operation 11 2 2 3 Current TPM Status Information 11 2 3 CPU Configuration 12 2 3 1 CPU Configuration 12 2 3 2 Max Freq Ratio 12 2 4 Firmware Up...

Страница 4: ...d frequency Minimum supported frequency etc 23 2 7 2 New SSC Mode 23 2 7 3 New SSC spread percentage 23 2 7 4 Apply settings immediately 24 2 7 5 Apply settings permanently after reboot 24 2 8 System...

Страница 5: ...Defaults Save Options 38 5 8 Save as User Defaults Save Options 38 5 9 Restore User Defaults Save Options 38 5 10 Boot Override 38 6 The uEFI Shell 41 6 1 Introduction Basic Operation 41 6 1 1 Shell...

Страница 6: ...f Startup Scripts 66 6 3 3 1 Automatic Booting from USB Flash Drive 66 6 3 3 2 Switch On Clock Spreading Prior to Booting from Harddrive 66 6 3 3 3 Execute Shell Script on Other Harddrive 66 6 3 3 4 E...

Страница 7: ...CP6004 SA RA RC CP6004X SA Starting uEFI BIOS Setup ID 1053 6161 Rev 3 0 Page 1 Starting uEFI BIOS Setup Chapter 1 1 D R A F T F O R I N T E R N A L U S E O N L Y...

Страница 8: ...Starting uEFI BIOS Setup CP6004 SA RA RC CP6004X SA Page 2 ID 1053 6161 Rev 3 0 D R A F T F O R I N T E R N A L U S E O N L Y This page has been intentionally left blank...

Страница 9: ...individual function settings for control or modification of the uEFI BIOS configuration and a Set up program which allows the accessing of various menus that provide functions or access to sub menus w...

Страница 10: ...at can be configured They are displayed in blue Functions displayed in gray provide information about the status or the operational configuration The right frame displays the key legend Above the key...

Страница 11: ...o save the current settings and exit the uEFI BIOS Setup Right Left The Right and Left Arrow keys are used to select a major Setup screen For example Main Screen Advanced Screen Chipset Screen etc Up...

Страница 12: ...Starting uEFI BIOS Setup CP6004 SA RA RC CP6004X SA Page 6 ID 1053 6161 Rev 3 0 D R A F T F O R I N T E R N A L U S E O N L Y This page has been intentionally left blank...

Страница 13: ...CP6004 SA RA RC CP6004X SA Main Setup ID 1053 6161 Rev 3 0 Page 7 Main Setup Chapter 1 2 D R A F T F O R I N T E R N A L U S E O N L Y...

Страница 14: ...Main Setup CP6004 SA RA RC CP6004X SA Page 8 ID 1053 6161 Rev 3 0 D R A F T F O R I N T E R N A L U S E O N L Y This page has been intentionally left blank...

Страница 15: ...version is reflected in the display only function Project Version parameter 14 00 indicates revision 14 Aptio Setup Utility Copyright C 2010 American Megatrends Inc Main Boot Security Save Exit BIOS...

Страница 16: ...ility Copyright C 2010 American Megatrends Inc Main Boot Security Save Exit TPM Configuration TPM Support Enable TPM State Enabled Pending TPM Operation None Current TPM Status Information TPM Enabled...

Страница 17: ...e this setting to prevent the system from issuing any TPM commands Enable Take Ownership Use this setting to allow the system to issue an Enable Take Ownership command during the next boot If this set...

Страница 18: ...ke a reduction in power consumption possible when higher performance is not required To ensure that the maximum desired frequency is not exceeded the CPU turbo mode must be disabled using the uEFI she...

Страница 19: ...disabled for the next boot However after the next boot this function shows Disabled Default setting Disabled Aptio Setup Utility Copyright C 2011 American Megatrends Inc Main Boot Security Save Exit...

Страница 20: ...d some BootLoaders Default setting Enabled Aptio Setup Utility Copyright C 2011 American Megatrends Inc Main Boot Security Save Exit USB Configuration USB Devices 1 Keyboard 1 Mouse 4 Hubs Legacy USB...

Страница 21: ...reports itself to the Host Controller Auto uses a default value for a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor If the Manual option is chosen the device power up d...

Страница 22: ...2 6 1 1 Console Redirection Default setting Enabled 2 6 1 2 Console Redirection Settings For information about this function refer to Chapter 2 6 2 2 in this manual Aptio Setup Utility Copyright C 201...

Страница 23: ...dently configured SETTING DESCRIPTION Disabled Use this setting to disable console redirection for COMB RS 232 Enabled Use this setting to enable console redirection for COMB RS 232 Aptio Setup Utilit...

Страница 24: ...RIPTION VT100 Use one of these settings to select the terminal type to be emulated VT100 VT UTF8 ANSI SETTING DESCRIPTION 9600 Use one of these settings to select the baud rate of the serial port 1920...

Страница 25: ...OS Redirection Default setting 80x24 SETTING DESCRIPTION None Use one of these settings to specify the type of flow control to be used for this serial port Hardware RTS CTS SETTING DESCRIPTION Disabl...

Страница 26: ...console output 2 6 3 1 Console Redirection Default setting Disabled SETTING DESCRIPTION VT100 Use one of the available settings to select the Function Key and the KeyPad when using Putty as terminal p...

Страница 27: ...TF8 Aptio Setup Utility Copyright C 2011 American Megatrends Inc Main Boot Security Save Exit Serial Port for Out of Band Management Console Redirection Settings Out of Band Mgmt Port COM0 Terminal Ty...

Страница 28: ...anagement 2 6 3 2 6 Parity This is a display only function providing information about the parity for Out of Band Manage ment 2 6 3 2 7 Stop Bits This is a display only function providing information...

Страница 29: ...e setting may lead to system instability 2 7 3 New SSC spread percentage Use this function to specify the requested Spread Spectrum Clock SSC in 0 01 increments Default setting 50 Aptio Setup Utility...

Страница 30: ...5 30 A M appears as 05 30 00 and 5 30 P M as 17 30 00 2 11 Access Level This function provides display only information concerning the uEFI BIOS Setup accessibility for the current Setup session The...

Страница 31: ...CP6004 SA RA RC CP6004X SA Boot Setup ID 1053 6161 Rev 3 0 Page 25 Boot Setup Chapter 1 3 D R A F T F O R I N T E R N A L U S E O N L Y...

Страница 32: ...Boot Setup CP6004 SA RA RC CP6004X SA Page 26 ID 1053 6161 Rev 3 0 D R A F T F O R I N T E R N A L U S E O N L Y This page has been intentionally left blank...

Страница 33: ...Exit Boot Configuration Setup Prompt Timeout 1 Bootup NumLock State On Quiet Boot Disabled Fast Boot Disabled CSM16 Module Version 07 68 GateA20 Active Upon Request Option ROM Messages Force BIOS Int...

Страница 34: ...n provides display only information concerning the CSM Module and is intended for internal use only 3 1 6 GateA20 Active This function is used to enable or disable GateA20 Default setting Upon Request...

Страница 35: ...elect the BBS class uEFI boot entry desired 3 2 2 Hard Drive Network Device CD DVD ROM Drive Floppy Drive BEV Device BBS Priorities These functions lead to sub menus that allow configuring the boot or...

Страница 36: ...Boot Setup CP6004 SA RA RC CP6004X SA Page 30 ID 1053 6161 Rev 3 0 D R A F T F O R I N T E R N A L U S E O N L Y This page has been intentionally left blank...

Страница 37: ...CP6004 SA RA RC CP6004X SA Security Setup ID 1053 6161 Rev 3 0 Page 31 Security Setup Chapter 1 4 D R A F T F O R I N T E R N A L U S E O N L Y...

Страница 38: ...Security Setup CP6004 SA RA RC CP6004X SA Page 32 ID 1053 6161 Rev 3 0 D R A F T F O R I N T E R N A L U S E O N L Y This page has been intentionally left blank...

Страница 39: ...ge Minimum length 3 Maximum length 20 Administrator Password User Password HDD Security Configur HDD 0 ST9120822SB Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values...

Страница 40: ...er it twice and acknowledge by pressing Re turn Note The password is case sensitive 4 3 HDD Security Configuration This function is not fully supported on the CP6004 SA RA RC CP6004X SA Warning Before...

Страница 41: ...CP6004 SA RA RC CP6004X SA Save Exit ID 1053 6161 Rev 3 0 Page 35 Save Exit Chapter 1 5 D R A F T F O R I N T E R N A L U S E O N L Y...

Страница 42: ...Save Exit CP6004 SA RA RC CP6004X SA Page 36 ID 1053 6161 Rev 3 0 D R A F T F O R I N T E R N A L U S E O N L Y This page has been intentionally left blank...

Страница 43: ...tup This function continues the boot process Note The Setup will ask for confirmation prior to executing this command 5 3 Save Changes and Reset This function is used to save all changes made within t...

Страница 44: ...mmand 5 7 Restore Defaults Save Options This function is used to restore all tokens to factory default Note The Setup will ask for confirmation prior to executing this command 5 8 Save as User Default...

Страница 45: ...CP6004 SA RA RC CP6004X SA The uEFI Shell ID 1053 6161 Rev 3 0 Page 39 The uEFI Shell Chapter 1 6 D R A F T F O R I N T E R N A L U S E O N L Y...

Страница 46: ...The uEFI Shell CP6004 SA RA RC CP6004X SA Page 40 ID 1053 6161 Rev 3 0 D R A F T F O R I N T E R N A L U S E O N L Y This page has been intentionally left blank...

Страница 47: ...the board as usual 6 1 1 Shell Startup If the shell is executed it displays its signon message followed by a list of detected devices The output produced by the device mapping table can vary depending...

Страница 48: ...tron system kBiosRevision kboardconfig kboardinfo kboot kbootnsh kclearnvram kflash kipmi kmkramdisk kpassword kresetconfig kwdt The following chapters provide information concerning these Kontron spe...

Страница 49: ...current uEFI BIOS revision is greater than number number uEFI BIOS revision number DESCRIPTION The kBiosRevision command is used to display the current uEFI BIOS revision In scripting environments it...

Страница 50: ...t status kboardconfig b lists options their current status and in vokes page breaks in the display output kboardconfig nc lists options their current status and dis ables color in the display output k...

Страница 51: ...splay auto Vga front SataMode ahci Sata0Speed Gen3 Sata1Speed Gen3 Sata2Speed Gen2 Sata3Speed Gen2 Sata4Speed Gen2 Sata5Speed Gen2 Sata0Hotplug disabled Sata1Hotplug disabled Sata2Hotplug disabled Sat...

Страница 52: ...olatile board settings Example kboardconfig option parameter Show all options and their current status kboardconfig Show help kboardconfig Show all options and their current status with page break kbo...

Страница 53: ...COMMAND RESPONSE EXAMPLE CP6004X SA Shell kboardconfig Pxe Pxe PXE boot device Available parameters disabled all gbe_a gbe_b rear_a rear_b gbe_e 10gbe_1 10gbe_2 In this case disabled is the current se...

Страница 54: ...X SA Gigabit Ethernet available on the front panel GbE B port gbe_b CP6004 RA Gigabit Ethernet available on the front panel GbE B port or on the rear I O LPd port gbe_b CP6004 RC Gigabit Ethernet avai...

Страница 55: ...ted During the bootup it is possible to select a menu to specify the desired RAID configuration Entry to this menu is achieved by pressing Ctrl I when requested during the bootup Sata0Speed Indicates...

Страница 56: ...select onboard SATA flash write protection If enabled the onboard SATA flash is write protected after POST OS needs to be prepared to work with write protected flash For further information refer to t...

Страница 57: ...oncentrated form USAGE Show board identification data COMMAND RESPONSE EXAMPLE CP6004 SA Shell kboardinfo KOMaOEMF rev 4 Board ID 0xB3D0 Hardware rev 0x0 Logic rev 0x1 Boot flash Standard SPI boot fla...

Страница 58: ...t flash Standard SPI boot flash In system slot No Geographic address 8 Material number Hardware index Serial number EFI article name SK EFI B3D01 EFI material number 1052 6900 EFI index 14 standard EF...

Страница 59: ...t flash Standard SPI boot flash In system slot No Geographic address 8 Material number Hardware index Serial number EFI article name SK EFI B3D01 EFI material number 1052 6900 EFI index 14 standard EF...

Страница 60: ...t flash Standard SPI boot flash In system slot No Geographic address 8 Material number Hardware index Serial number EFI article name SK EFI B3D01 EFI material number 1052 6900 EFI index 14 standard EF...

Страница 61: ...e slot the board is currently plugged into Material number Kontron hardware reference number Hardware index Kontron hardware index Serial number This board s unique serial number EFI article name Kont...

Страница 62: ...boot returns to shell The kboot command cannot boot native uEFI aware operating systems But since these are bootable from shell by calling their bootloader this is not necessary either If a requested...

Страница 63: ...sh stored startup script If the shell is launched by the boot process it executes a shell script stored in the flash If the shell script terminates the shell executes a kboot d command to continue the...

Страница 64: ...ash banks holding the uEFI BIOS code uEFI BIOS binary files must be available from connected mass storage devices such as USB flash drive or harddisk USAGE Get help COMMAND RESPONSE EXAMPLE Shell kfla...

Страница 65: ...ngs sel handle system event log sensor show sensor related information raw execute raw ipmi command rawsendmessage execute raw SendMessage ipmi cmd info show information about the device and firmware...

Страница 66: ...ID Displays FRU data Options Fru device ID Numeric FRU device ID The FRU ID 0 is used by default if no FRU ID is entered ipmb Displays IPMB bus settings ipmb redundant Switch IPMB bus to redundant mod...

Страница 67: ...how board sensor data Options list Display an overview of all available board sensors read Display specific sensor data raw bytes Execute raw IPMI command Syntax raw NetFn LUN COMMAND rawsendmessage b...

Страница 68: ...nnected to the system Note The RAMdisk loses its mount point name after all drives are remapped by the map r command The RAMdisk will then be enumerated as any other connected drive and gain a mount p...

Страница 69: ...d scripting n New password to be set Use together with options u or s o Submit password if one is already set Use together with options u or s When used with out the option n the password is cleared N...

Страница 70: ...PCI backplane reset if it is used as slave board in a peripheral slot It has no effect if the board is located within a CPCI mas ter slot Note This parameter is volatile and at next start is set to of...

Страница 71: ...s required for this functionality to operate USAGE Get help COMMAND RESPONSE EXAMPLE Shell kwdt t time set Timer value 0 125ms value 1 250ms value 2 500ms value 3 1s value 4 2s value 5 4s value 6 8s v...

Страница 72: ...OS with a plain text editor of your choice To create a startup shell script simply save the script on any FAT formatted drive attached to the system under the file name efi boot startup nsh To copy t...

Страница 73: ...hows two uEFI Shell environment variables wdt_enable and pxe_first used to control the boot process and the Watchdog To create uEFI Shell environment variables use the set uEFI Shell command as shown...

Страница 74: ...and set the proper working directory as shown below 6 Enter the sample start up script mentioned above in this section using the edit uEFI Shell command 7 Save the start up script to the uEFI flash b...

Страница 75: ...CP6004 SA RA RC CP6004X SA Updating the uEFI BIOS ID 1053 6161 Rev 3 0 Page 69 Updating the uEFI BIOS Chapter 1 7 D R A F T F O R I N T E R N A L U S E O N L Y...

Страница 76: ...Updating the uEFI BIOS CP6004 SA RA RC CP6004X SA Page 70 ID 1053 6161 Rev 3 0 D R A F T F O R I N T E R N A L U S E O N L Y This page has been intentionally left blank...

Страница 77: ...ting or cloning the uEFI BIOS ensure that the ME FW Image Re Flash function in the Main Setup menu is set to Enable refer to Chapter 2 4 1 for further information Failure to comply with the above may...

Страница 78: ...Updating the uEFI BIOS CP6004 SA RA RC CP6004X SA Page 72 ID 1053 6161 Rev 3 0 D R A F T F O R I N T E R N A L U S E O N L Y This page has been intentionally left blank...

Отзывы: