1.3 Technical Specif ication
Table 1: CP6108X Main Specifications
FEATURES
SPECIFICATIONS
Switch
PCI Express Switch
ExpressLane™ PEX 8724 PCI Express 3.0 switch from PLX Technology used to provide
maximum performance to an MXM module:
» One x8 PCI Express Gen3 upstream port
» One x16 PCI Express Gen3 downstream port
Co
nnect
or
s
DVI
Two DVI interfaces on the front panel routed to the rear I/O connector J5:
» One standard DVI-D connector, J14
» One standard DVI-I connector, J15
DisplayPort
Four DisplayPort connectors, J7, J8, J9, and J10
MXM3.0
One standard MXM3.0 connector, J11, for connecting an MXM3.0 type A or type B
module to the CP6108X
High-Speed Serial
I/O Interconnection
The following interface is provided to the backplane via two high-speed serial
ZDplus connectors, J4 and J41 (PICMG 2.20):
» One x8 PCI Express 3.0 interface operating at 8 GT/s as end point (non-trans-
parent bridge)
CompactPCI
CompactPCI interface:
» Compliant with CompactPCI Specification PICMG
2.0 R 3.0:
» Peripheral slot functionality
» 3.3V or 5V signaling levels (universal signaling support)
» No hot swap support
» Four CompactPCI connectors J1, J2, J3 and J5
LED
Front Panel LED
Power Status LED:
» PWR (green):
Power Status of the CP6108X/MXM module
» TMP (green/orange/red): Temperature Status of the MXM module
Gener
al
Mechanical
6U, 4 HP, CompactPCI-compliant form factor
Power Consumption
approx. 3 W (without MXM module)
Power Supply
3.3V and 5V DC in accordance with the CompactPCI® specification
op12V DC external voltage for MXM module voltage supply only
Temperature Range
(without MXM module)
Operational:
0°C to +60°C
Standard
-40°C to +70°C
Extended (with sufficient cooling for the PCI
Express switch)
Storage:
-40°C to +85°C
Cooling
Depending on the integrated MXM3.0 module, an appropriate heat sink for the
module and the PCI Express switch as well as sufficient airflow must be provided to
ensure optimal operation and long-term reliability of the CP6108X. For further
information, please contact Kontron.
Climatic Humidity
93% RH at 40 °C, non-condensing (acc. to IEC 60068-2-78)
Dimensions
233.35 mm x 160 mm
Board Weight
440 grams (without MXM module and without cooling solution)