Software Setup

108

AT8060

www.kontron.com

5.3

Console Redirection (VT100 Mode)

The VT100 operating mode allows remote setup of the board. This configuration requires a remote terminal 
that must be connected to the board through a serial communication link.

5.3.1

Requirements

The terminal should emulate a VT100 or an ANSI terminal. Terminal emulation programs such as Putty, 
Telix©, HyperTherminal(Windows), minicom(Linux) or ProComm©(Windows) can also be used.

5.3.2

ANSI and VT100 Keystroke Mapping

5.3.3

VT-UTF8 Keystroke Mapping

The following "escape sequences" are defined in the "Conventions for Keys Not in VT100 Terminal Definition 
and ASCII Character Set" section of "Standardizing Out-of-Band Management Console Output and Terminal 
Emulation (VT-UTF8 and VT100+)",available for download at microsoft.com.

Up

<ESC>[A

Down

<ESC>[B

Right

<ESC>[C

Left

<ESC>[D

Home

<ESC>[H

End

<ESC>[K

F1

<ESC>OP

F2

<ESC>OQ

F3

<ESC>OR

F4

<ESC>OT

F1 Key

<ESC>1

F2 Key

<ESC>2

F3 Key

<ESC>3

F4 Key

<ESC>4

F5 Key

<ESC>5

F6 Key

<ESC>6

F7 Key

<ESC>7

F8 Key

<ESC>8

F9 Key

<ESC>9

F10 Key

<ESC>0

Содержание AT8060

Страница 1: ...If it s embedded it s Kontron Kontron User s Guide AT8060 Document Revision 1 1 June 2012...

Страница 2: ...guide contains information proprietary to Kontron Customers may reprint and use this user s guide in other publications Customers may alter this user s guide and publish it only after they remove the...

Страница 3: ...ii Limited Warranty xiv 1 Product Description 2 1 1 Product Overview 2 1 2 What s Included 2 1 3 Board Specifications 3 1 4 Compliance 5 1 5 Hot Plug Capability 5 1 6 Interfacing with the Environment...

Страница 4: ...nstalling the Board 20 3 1 Setting Jumpers 20 3 1 1 Jumper Description 20 3 1 2 Jumper Setting Locations 21 3 2 Processor 21 3 3 Memory 21 3 3 1 Memory List and Characteristics 22 3 3 2 Installing Mem...

Страница 5: ...ecords 41 4 6 3 FRU Information 58 4 6 4 Clock E Keying Information 63 5 Software Setup 65 5 1 AMI UEFI Setup Program 65 5 1 1 Accessing the UEFI Setup Utility 65 5 1 2 Menu Bar 66 5 1 3 Main Menu 68...

Страница 6: ...onnectors and Headers Summary B 1 B 2 Post Codes J2 B 1 B 3 AMC B1 J19 B 2 B 4 USB Dual Port J12 B 3 B 5 Serial Port COM1 J13 B 3 B 6 USB Flash Drive J10 J11 B 3 B 7 Base Interface Fabric Interface J2...

Страница 7: ...9 Figure 2 2 Faceplate LEDs 18 Figure 3 1 Jumper Settings and Locations 21 Figure 3 2 Onboard Connectors and Headers Locations 24 Figure 4 1 E Keying possibilities 60 Figure 6 1 Pressure Curve in Impe...

Страница 8: ...able 4 8 Sensor Device Supported Commands for IPMC 36 Table 4 9 FRU Device Supported Commands for IPMC 37 Table 4 10 SDR Device Supported Commands for IPMC 37 Table 4 11 SEL Device Supported Commands...

Страница 9: ...uthorized electronics service personnel should access the interior of the computer The power supplies produce high voltages and energy hazards which can cause bodily harm Use extreme caution when inst...

Страница 10: ...are at an ESD workstation or grounded This will discharge any static electricity that may have built up in your body When transporting a sensitive component first place it in an antistatic container...

Страница 11: ...assumes no responsibility as far as patents or other rights of third parties are concerned The following is a summary of chapter contents Chapter 1 Product Description Chapter 2 Board Features Chapter...

Страница 12: ...ons that might require the use of a Caution or a Warning Note Indicate information that is important for you to know Signal Path Indicate the places where you can find the signal on the board Jumper S...

Страница 13: ...following items Make sure that all connectors are properly connected Verify your boot devices If the system does not start properly try booting without any other I O peripherals attached including AMC...

Страница 14: ...Kontron equipment meets or exceeds safety requirements based on the IEC EN UL CSA 60950 1 family of standards entitled Safety of information technology equipment All components are chosen to reduce fi...

Страница 15: ...l cost of purchase if appropriate In the event of repair refunding or replacement of any part the ownership of the removed or replaced parts reverts to Kontron and the remaining part of the original g...

Страница 16: ...8060 Chapter 1 Product Description www kontron com 1 1 Product Overview 2 1 2 What s Included 2 1 3 Board Specifications 3 1 4 Compliance 5 1 5 Hot Plug Capability 5 1 6 Interfacing with the Environme...

Страница 17: ...he Patsburg B is connected to the processors via a DMI2 interface and to various I O components Three Ethernet controllers from Intel are implemented to provide high speed interfaces in the fabric int...

Страница 18: ...GEN1 1 5Gb s GEN2 3Gb s GEN3 6Gb s and SAS 3Gb s storage interfaces on the RTM I O Dual SFP Dual USB RJ45 Serial Port TPM mezzanine Video debug port available on the RTM Board Specifications PICMG3 0...

Страница 19: ...and running IPMI Hardware system monitor power voltages memory and all critical component s is monitored Extensive sensor monitoring around 100 IPMI sensors and event generation based on thresholds a...

Страница 20: ...n the system while it is on without powering down the system Please refer to the PICMG3 0 R3 0 specification for additional details about Hot Swap The AT8060 supports PCI Express Hotplug on AMC B1 and...

Страница 21: ...er to the RTM Once the IPMB L link is working the IPMC accesses the MMC to retrieve FRU data After knowing the type of RTM inserted the IPMC negotiates with the shelf manager in order to activate the...

Страница 22: ...Product Description 7 AT8060 www kontron com PCI Express clock on FCLKA SATA on AMC port...

Страница 23: ...e 10 2 3 USB 2 0 Interfaces 10 2 4 USB Flash Module 11 2 5 Serial ATA Serial Attached SCSI 11 2 6 Redundant BIOS Flash 12 2 7 Ethernet Interfaces 12 2 8 Serial Interfaces 14 2 9 AMC Mezzanine 14 2 10...

Страница 24: ...2 Board Features 2 1 Block Diagram Figure 2 1 Block Diagram 0 0 1 2 3 4 5 6 7 7 8 9 8 8 19 9 6 6 0 8 A 0 0 0 1 2 3 4 5 B B B B 7C B 0 DD 2 0 A6 E C 3 4 5 3 4 5 E 9 9 9 E F E 8 G 7 7 8 G G 8 8 F B6 C C...

Страница 25: ...echnology HT 2 2 2 Intel Patsburg PCH Direct Media Interface DMI x4 lanes for communicating with CPU0 SATA Gen3 up to 6Gbps SAS Gen2 up to 3Gbps USB 2 3 USB 2 0 Interfaces The board embeds a USB contr...

Страница 26: ...Gb s GEN3 6Gb s and SAS 3Gb s on the RTM storage interfaces 2 5 2 Serial ATA PCH The PCH SATA port 0 is connected to the AMC Port 2 It supports SATA GEN1 1 5Gb s GEN2 3Gb s and GEN3 6Gb s on the AMC s...

Страница 27: ...This controller can also be used as a dual 1Gb The controller auto negociates between 10G BASE KX4 and 1G BASE KX Features high performance with TCP IP and UDP IP checksum offloading for IPv4 and IPv...

Страница 28: ...Table 2 1 SFP LED Significations Signal Path The two ports are available on the Base Interface BIOS Settings Advanced Legacy Expansion ROM Configuration BI GE OpROM Port 1 and 2 Signal Path The front...

Страница 29: ...hot swappable according to PICMG 3 0 Rev 2 0 and supports mid size AMC units One AMC site is available Characteristics of the AMC are as follow Type B Supports mid size single width mechanical format...

Страница 30: ...C firmware is being updated The FPGA is a RAM based chip that is preloaded from a separate flash memory at power up Two such flash memory devices are provided one that can only be programmed in factor...

Страница 31: ...During normal operation this LED is OFF Note The IPMC has an external hardware watchdog LED Name Color Controlled by Description HDD activity Green Chipset FPGA AMC RTM HDD activity status ATCA0 Blue...

Страница 32: ...are upgrade and is user configurable if needed by a customer application 2 12 3 Healthy LED LED2 The AdvancedTCA LED2 is green or amber and indicates a healthy condition The healthy LED indicates if t...

Страница 33: ...ayload power down Green Health Ok Amber Health Error Critical Application Defined May be controlled by application using PICMG API Hard Disk Activity Led Green Blink Hard Disk Activity FI Led Green Am...

Страница 34: ...Chapter 3 Installing the Board www kontron com 3 1 Setting Jumpers 20 3 2 Processor 21 3 3 Memory 21 3 4 Onboard Connectors and Headers 24 3 5 Board Hot Swap and Installation 25...

Страница 35: ...ears the BIOS Setup JP2 5 6 Reserved Reserved JP2 7 8 Reserved Reserved JP2 9 10 Reserved Reserved JP2 11 12 Onboard video enable When On it enables onboard video controller JP2 13 14 Watchdogs When O...

Страница 36: ...n heatsink and may necessitate a certain class of chassis It is recommended that modules have thermal sensors for accurate temperature monitoring and to Note More details about the jumper settings can...

Страница 37: ...dual rank modules are supported x4 or x8 memory with up to 4 ranks per DIMM Registered ECC Only very low profiles VLP 0 72inches maximum heights 18 3mm Manufacturer Part Number Description Company M39...

Страница 38: ...the memory module into any available socket aligning the notches on the module with the socket s key inserts Push down the memory module until the retaining clips lock on each side Repeat these steps...

Страница 39: ...ors J10 J11 USB Connectors for the USB SSD Modules USB Connectors J12 Dual USB Connector Management Console Port J13 RJ 45 Serial Port Connector SFP Connectors J15 J17 Faceplate SFP Connectors AMC con...

Страница 40: ...figured properly 3 Carefully align the PCB edges in the bottom and top card guide 4 Insert the board in the system until it makes contact with the backplane connectors 5 Using both ejector handles eng...

Страница 41: ...he RTM806X or RTM8050 To install the RTM 1 Remove the filler panel of the slot 2 Ensure the board is configured properly 3 Carefully align the PCB edges in the bottom and top card guide 4 Insert the b...

Страница 42: ...Management www kontron com 4 1 Hardware Management Overview 28 4 2 Configuring LAN interface 28 4 3 Web Management Interface 28 4 4 Hardware Management Functionality 31 4 5 IPMC Specific Features 31 4...

Страница 43: ...in the address or configure it Enter the BIOS Setup Go to Set BMC network configuration menu which is located under Server Mgmt Choose the LAN channel to be configured Select state and IP source stati...

Страница 44: ...ally refreshed Refer to Table 4 20 for a list of sensors for this board 4 3 4 Event Log 4 3 4 1 Reading This page displays System Event Log SEL information and the event list The SEL can have up to 51...

Страница 45: ...rs can be enabled or disabled Privilege levels are defined in the table below Table 4 1 Privilege Level Description The User ID 1 is a user without name and password This user can be enabled or disabl...

Страница 46: ...so have responsibility for detecting and recovering from IPMB faults The reliability of the AdvancedTCA IPMB 0 is increased by using two IPMBs with the two IPMBs referenced as IPMB A and IPMB B The ag...

Страница 47: ...ts are logged into the local SEL the IPMI platform event messages are still generated by the IPMC s Event Generator and sent to the centralized SEL hosted by the Shelf Manager through the IPMB 0 commu...

Страница 48: ...02h O O Yes Warm Reset 20 3 App 03h O O No Get Self Test Results 20 4 App 04h M M Yes Manufacturing Test On 20 5 App 05h O O Yes Set ACPI Power State 20 6 App 06h O O Yes Get ACPI Power State 20 7 App...

Страница 49: ...nel Access 22 22 App 40h O O Yes Get Channel Access 22 23 App 41h O O Yes Get Channel Info 22 24 App 42h O O Yes Set User Access 22 26 App 43h O O Yes Get User Access 22 27 App 44h O O Yes Set User Na...

Страница 50: ...O M O Yes Chassis Control 28 3 Chassis 02h O M O Yes Chassis Reset 28 4 Chassis 03h O O No Chassis Identify 28 5 Chassis 04h O O No Set Chassis Capabilities 28 7 Chassis 05h O O No Set Power Restore P...

Страница 51: ...cknowledge 30 8 S E 17h O O No IPMI Spec section NetFn CMD IPMI BMC req Carrier IPMC req Kontron support on IPMC Sensor Device Commands O M Get Device SDR Info 35 2 S E 20h O M Yes Get Device SDR 35 3...

Страница 52: ...M M No Get SDR 33 12 Storage 23h M M No Add SDR 33 13 Storage 24h M O M No Partial Add SDR 33 14 Storage 25h M O M No Delete SDR 33 15 Storage 26h O O No Clear SDR Repository 33 16 Storage 27h M O M N...

Страница 53: ...ort 02h O M O M Yes Suspend BMC ARPs 23 3 Transport 03h O M O M Yes Get IP UDP RMCP Statistics 23 4 Transport 04h O O Yes IPMI Spec section NetFn CMD IPMI BMC req Carrier IPMC req Kontron support on I...

Страница 54: ...ron support on IPMC AdvancedTCA PICMG 3 0 Table M Get PICMG Properties 3 11 PICMG 00h M Yes Get Address Info 3 10 PICMG 01h M Yes Get Shelf Address Info 3 16 PICMG 02h O Yes Set Shelf Address Info 3 1...

Страница 55: ...s FRU Inventory Device Lock Control 3 42 PICMG 1Fh M No FRU Inventory Device Write 3 43 PICMG 20h M No Get Shelf Manager IP Addresses 3 36 PICMG 21h M No Get Shelf Power Allocation 3 85 PICMG 22h M No...

Страница 56: ...s the Sensor Device Commands to gather this information Thus commands such as Get Device SDR Info and Get Device SDR which are optional in the IPMI specification are mandatory in AdvancedTCA systems M...

Страница 57: ...sage 3 FRU3 Hot Swap Discrete ATCA Board FRU Hot Swap Sensor for FRU 3 RTM Disk 1 Available only when RTM and 1 disk is inserted Sensor type code F0h PICMG Hot Swap Event Reading type code 6Fh Sensor...

Страница 58: ...s Sensor type 01h temperature Event Reading type code 01h threshold based See IPMI v2 0 table 42 2 for threshold based event 12 Temp DIMM A Threshold DIMM A Temperature Degrees Sensor type 01h tempera...

Страница 59: ...inserted Sensor type 01h temperature Event Reading type code 01h threshold based See IPMI v2 0 table 42 2 for threshold based event 22 Temp Disk2 Threshold Disk 2 Temperature Degrees Available only w...

Страница 60: ...or type 02h voltage Event Reading type code 01h threshold based See IPMI v2 0 table 42 2 for threshold based event 30 Vcc 3 3V SUS Threshold Voltage on board 3 3V suspend management power supply Volts...

Страница 61: ...for threshold based event 38 Vcc 1 2V Threshold Voltage on board 1 2V payload power supply Volts Sensor type 02h voltage Event Reading type code 01h threshold based See IPMI v2 0 table 42 2 for thres...

Страница 62: ...e on board CPU1 VDDQ payload power supply Volts Sensor type 02h voltage Event Reading type code 01h threshold based See IPMI v2 0 table 42 2 for threshold based event 48 Vcc VSA CPU 1 Threshold Voltag...

Страница 63: ...EM sensor table Event Reading type code 77h for sensor definition 55 Board Reset Discrete Board reset type and sources Sensor type CFh OEM Kontron Reset Sensor Event Reading type code 03h Digital Disc...

Страница 64: ...c Only offset 0 1 4 5 6 7 are used See IPMI v2 0 table 42 3 Sensor type 25h Entity Presence for sensor definition 61 DIMM D Status Discrete DIMM D Status Presence Sensor type 25h Entity Presence Event...

Страница 65: ...mory Resize Event Reading type code 03h Digital Discrete Only offset 0 1 are used See IPMI v2 0 table 42 3 Event Reading type code 0Eh for sensor definition 67 Boot Error Discrete Boot Error Sensor Ty...

Страница 66: ...Sensor Specific Only offset 7 and 8 are used See IPMI v2 0 table 42 3 Sensor type code 13h for sensor definition 73 PCIe FI Error Discrete Fabric Interface PCIe Error Sensor type 13h Critical Interru...

Страница 67: ...0 table 42 3 Sensor type code 23h Watchdog 2 for sensor definition 79 Health Error Discrete General health status Aggregation of critical sensor This list is flexible and could be adjust based on cus...

Страница 68: ...ent Reading type code 6Fh Sensor Specific Only offset 0 1 5 are used See IPMI v2 0 table 42 3 Sensor type code 07h for sensor definition 85 CPU1 Status Discrete Processor 1 Status Sensor type 07h Proc...

Страница 69: ...gent FRU1 Data Error Detection Sensor type C5h OEM Kontron FRU Info Agent Event Reading type code 0Ah Generic Discrete Only offset 6 8 are used see OEM table Sensor type code C5h Kontron OEM FRU Infor...

Страница 70: ...Mc Sensor type 1Bh Cable Interconnect Event Reading type code 03h Digital Discrete See IPMI v1 5 table 36 2 and table 36 3 for sensor definition 99 IPMC Reboot Discrete IPMC reboot detection Sensor ty...

Страница 71: ...ition 104 ME Availability Discrete Provides status on the chipset Management Engine Sensor type 28h Management Subsystem Health Event Reading type code 0Ah Generic Discrete offset 2 6 8 are used See I...

Страница 72: ...or definition 109 IPMI Info 1 Discrete Internal Management Controller firmware diagnostic Sensor type C0h Kontron OEM Firmware Info Event Reading type code 70h Kontron OEM Internal Diagnostic See OEM...

Страница 73: ...VDDQ CPU 0 45 Vcc VSA CPU 0 46 Vcc PLL CPU 0 47 Vcc VCORE 1 48 Vcc VTT CPU 1 49 Vcc VDDQ CPU 1 50 Vcc VSA CPU 1 51 Vcc PLL CPU 1 52 Fuse Pres A Feed 53 Fuse Pres B Feed 55 Power Good 56 Power Good Ev...

Страница 74: ...n Board FRU ID FRU5008 12 Board Extra BI1MAC XX XX XX XX XX XX Board Extra BI2MAC XX XX XX XX XX XX Board Extra CPUID Product Information Area Product Manufacturer Kontron Product Name AT8060 Product...

Страница 75: ...ng Section The board e keying information contains PICMG 3 0 R3 0 defined channel and link descriptors required for matchmaking computation by the ShMC The following figure gives all E Keying possibil...

Страница 76: ...2 01h PICMG 3 0 Base Interface 10 100 1000 BASE T Link Designator Bits 11 0 102h Base Interface Channel 2 Port 0 Link Descriptor 00102F41h Link Grouping ID Bits 31 24 0h Single Channel link Link Type...

Страница 77: ...k Link Type Extension Bits 23 20 0h Fixed 1000Base BX Link Type Bits 19 12 02h PICMG 3 1 Ethernet Fabric Interface Link Designator Bits 11 0 142h Fabric Interface Channel 2 Port 0 Link Descriptor 000F...

Страница 78: ...he board has a clock generator used as the PCIe FCLKA of AMC B1 Field Value Record Type ID C0h Record format version 02h Record Length Calculated Record Checksum Calculated Header Checksum Calculated...

Страница 79: ...64 AT8060 Chapter 5 Chapter 5 Software Setup www kontron com 5 1 AMI UEFI Setup Program 65 5 2 Boot Utilities 107 5 3 Console Redirection VT100 Mode 108...

Страница 80: ...ating system and the hardware of the AT8060 It uses the AMI Setup program a setup utility in flash memory that is accessed by pressing the F2 key at the appropriate time during board boot This utility...

Страница 81: ...r has a full understanding of the timing relationships involved Note All options in Bold are the default settings WARNING BIOS V0 70 and higher is required to operate the board with a ES 2600 series p...

Страница 82: ...f each menu displays the help text for the selected field It updates as you move the cursor to each field 5 1 2 3 General Help Windows Pressing F1 on any menu brings up the General Help window that de...

Страница 83: ...ndor Core Version Compliancy Project Version Build Date and Time Memory Information Total Memory Total Memory in the System System Language Choose the system default language System Date Set the Date...

Страница 84: ...eneral WHEA Configuration settings CPU Configuration Selects sub menu CPU Configuration Parameters Runtime Error Logging Selects sub menu Runtime Error Logging Support Setup Options Legacy Expansion R...

Страница 85: ...4 bit PCI Decoding PCI Common Settings PCI Latency Timer 32 PCI Bus Clocks 64 PCI Bus Clocks 96 PCI Bus Clocks 128 PCI Bus Clocks 160 PCI Bus Clocks 192 PCI Bus Clocks 224 PCI Bus Clocks 248 PCI Bus C...

Страница 86: ...BLED allows Device to use 8 bit Tag field as a requester No Snoop Disabled Enabled Enables or Disables PCI Express Device No Snoop option Maximum Payload Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes...

Страница 87: ...n of Extended Synchronization patterns Link Training Retry Disabled 2 3 5 Defines number of Retry Attempts software will take to retrain the link if previous training attempt was unsuccessful Link Tra...

Страница 88: ...nabled the Downstream Port disables its traditional Device Number field being 0 enforcement when turning a Type1 Configuration Request into a Type0 Configuration Request permitting access to Extended...

Страница 89: ...TLP Prefix Blocking Disabled Enabled If supported by hardware and set to Enabled this function will block forwarding of TLPs containing End End TLP Prefixes PCI Express GEN2 Link Register Settings Ti...

Страница 90: ...dered Sets between sequences when sending Compliance Pattern or Modified Compliance Pattern Hardware Autonomous Width Enabled Disabled If supported by hardware and set to Disabled this will disable th...

Страница 91: ...Disabled for other OS OS not optimized for Hyper Threading Technology When Disabled only one thread per enabled core is enabled Active Processor Cores All 1 2 4 6 Number of cores to enable in each pro...

Страница 92: ...ration Parameters Feature Option Description Help text Socket 0 CPU Information Subtitle CPU Signature Display only Displays CPU Signature Microcode Patch Display only CPU Microcode Patch Revision Max...

Страница 93: ...achines L1 Data Cache Display only L1 Data Cache Size L1 Code Cache Display only L1 Code Cache Size L2 Cache Display only L2 Cache Size L3 Cache Display only L3 Cache Size Feature Option Description H...

Страница 94: ...OpROM Port 1 Disabled Enabled Enabled initializesFront Panel Management GbE port 1 Expansion ROM Disabled PCI Expansion ROM not used to boot the system FP GE OpROM Port 2 Disabled Enabled Enabled init...

Страница 95: ...n ROM used to boot the system Feature Option Description Help text SATA Configuration Subtitle SATA Port0 Display only SATA Ports 0 5 Device Names if Present and Enabled SATA Mode Disabled IDE Mode AH...

Страница 96: ...ion Description Help text Thermal Configuration Subtitle Thermal Management Disabled Enabled Thermal Management Enable Disable If Enabled will initilaize the PCH Thermal susbsystem device D31 F6 ME SM...

Страница 97: ...EHCI Hand off Disabled Enabled This is a workaround for OSes without EHCI hand off support The EHCI ownership change should be claimed by EHCI driver Port 60 64 Emulation Disabled Enabled Enables I O...

Страница 98: ...s Mass Storage Devices Display only USB Device X Auto Floppy Forced FDD Hard Disk CD ROM Available on detected device Mass storage device emulation type AUTO enumerates devices according to their medi...

Страница 99: ...4 IO 3F8h IRQ 3 4 5 6 7 10 11 12 IO 2F8h IRQ 3 4 5 6 7 10 11 12 IO 3E8h IRQ 3 4 5 6 7 10 11 12 IO 2E8h IRQ 3 4 5 6 7 10 11 12 Selectan optimal setting for IO device Feature Option Description Help tex...

Страница 100: ...ion Disabled Enabled Console Redirection Enable or Disable Console Redirection Settings Selects sub menu The settings specify how the host computer and the remote computer which the user is using will...

Страница 101: ...dows Server OS through a serial port Terminal Type VT100 VT100 VT UTF8 ANSI VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in...

Страница 102: ...Parity Display only A parity bit can be sent with the data bits to detect some transmission errors Even parity bit is 0 if the num of 1 s in the data bits is even Odd parity bit is 0 if num of 1 s in...

Страница 103: ...atched on the other side Long or noisy lines may require lower speeds Data Bits 7 8 Data Bits Parity None Even Odd Mark Space A parity bit can be sent with the data bits to detect some transmission er...

Страница 104: ...sables extended terminal resolution Legacy OS Redirection Resolution 80x24 80x25 On Legacy OS the Number of Rows and Columns supported redirection Putty KeyPad VT100 LINUX XTERMR6 SCO ESCN VT400 Selec...

Страница 105: ...hars onto 1 or more bytes Bits per second 9600 19200 38400 57600 115200 Selects serial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds...

Страница 106: ...art stop signals VT UTF8 Combo Key Support Disabled Enabled Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Recorder Mode Disabled Enabled With this mode enabled only text will be sent...

Страница 107: ...play only Possible Memory mode Memory Mode Independent Mirroring Lock Step Sparing Select the mode for memory initialization Spare Err Threshold Numeric Set Spare Err Threshold DRAM RAPL BWLIMIT 0 1 8...

Страница 108: ...Disabled Enabled Enable Disable Rank Margin Thermal Throttling Disabled OLTT CLTT CLTT Closed Loop Thermal Throttling OLTT Open Loop Thermal Throttling OLTT Peak BW Numeric Valid Offset 25 100 This i...

Страница 109: ...es Disables Direct Cache Access Support VGA Priority Onboard Offboard Decidesprioritybetween onboard and 1st offboard video device found TargetVGA Display Only TargetVGA fromRootPort under CPU0 CPU1 C...

Страница 110: ...Ratio Skt0 Numeric Value ranges are from 1 8 Ratio calculated based on value selected total value of all sockets If granularity fails resources will be allocated equally for all sockets Io Ratio Skt1...

Страница 111: ...ter Feature Option Description Help text Current QPI Link Speed Display Only Current QPI Link Speed Current QPI Link Freq Display Only Current QPI Link Freq Isoc Disabled Enabled Enbale Disable Isoc Q...

Страница 112: ...abled Disabled SLP_S4 Assertion Stretch SLP_S4 Assertion Width 1 2 Seconds 2 3 Seconds 3 4 Seconds 4 5 Seconds Select a minimum assertion width of the SLP_S4 signal Deep Sx Disabled Enabled in S5 Batt...

Страница 113: ...s Ports in the Chipset PME SCI Disabled Enabled Enable or disable the PCI Express PME SCI DMI Vc1 Control Enabled Disabled Enable Disable DMI Vc1 DMI Vcp Control Enabled Disabled Enable Disable DMI Vc...

Страница 114: ...tem Help ME BIOS Interface Version Display only ME BIOS Interface Version implemented on ME side ME Version Display only ME firmware Version ME FW Status Value Display only ME FW State Display only Cu...

Страница 115: ...cts sub menu Managed FRU Deactivate Policies Power Limit options Selects sub menu Power Limit options Watchdog Configuration Selects sub menu Enable or Disable management watchdog timer View FRU infor...

Страница 116: ...eshold value Exception Action No action Hard Power Off System and log event to SEL Log event to SEL only Exception action taken if the Power Limit is exceeded and cannot be controlled within the Corre...

Страница 117: ...cessfully loaded or follows the OS Boot Watchdog Timer policy OS Wtd Timer Timeout 30 seconds 1 minute 3 minutes 5 minutes 10 minutes 15 minutes 20 minutes Configure the length of the OS Boot Watchdog...

Страница 118: ...AN channel parameters statically or dynamically DHCP Changes will be applied on next reboot BMC IP address Display only if Dynamic Enter BMC IP address Subnet mask Display only if Dynamic Enter subnet...

Страница 119: ...Enter BMC IP address Subnet mask Display only if Dynamic Enter subnet mask Gateway IP address Display only if Dynamic Enter Gateway IP address BMC IP address Enter BMC IP address Subnet mask Enter su...

Страница 120: ...est Always UPON REQUEST GA20 can be disabled using BIOS services ALWAYS do not allow disabling GA20 this option is useful when any RT code is executed above 1MB Option ROM Messages Force BIOS Keep Cur...

Страница 121: ...range Minimum length 3 Maximum length 20 Text Administrator Password Set Administrator Password User Password Set User Password Feature Option Description Help text Save Changes and Exit Exit system...

Страница 122: ...initialization 4 Select SCSI LSI MPI Boot Support in Popup menu The menu is now available 5 2 3 SAS Option ROM RTM806X To access the SAS Option ROM follow the procedure listed below 1 The RTM806X with...

Страница 123: ...or ProComm Windows can also be used 5 3 2 ANSI and VT100 Keystroke Mapping 5 3 3 VT UTF8 Keystroke Mapping The following escape sequences are defined in the Conventions for Keys Not in VT100 Terminal...

Страница 124: ...I Serial Redirection supports these key sequences under two configurations Terminal Type setup question is set to VT UTF8 Terminal Type setup question is set to VT100 or ANSI and VTUTF8 Combo Key Supp...

Страница 125: ...110 AT8060 Chapter 6 Thermal Considerations www kontron com 6 1 Thermal Monitoring 111...

Страница 126: ...est possible thermal resistance Additionally the heat sinks were specifically designed to use forced airflow as found in ATCA systems 6 1 2 Temperature Sensors The AT8060 is equipped with 14 temperatu...

Страница 127: ...6 1 Temperature Sensors Thresholds Sensor ID Lower Thresholds Upper Thresholds Minor Major Critical Minor Major Critical Temp 48V A Feed N A 0 C 10 C 75 C 85 C 110 C Temp 48V B Feed N A 0 C 10 C 75 C...

Страница 128: ...tips about thermal operational range of the system carrying the AT8060 Once volumetric airflow capability of your chassis is known the PQ curve can help determine the ambient room temperature setpoin...

Страница 129: ...er to the figure below for more details Figure 6 3 CPU Thermal Profile 20 30 40 50 60 70 80 90 0 10 20 30 40 50 60 70 80 90 100 Maximum Ambient Temperature oC CPU Socket power Consumption W Maximum Am...

Страница 130: ...em BIOS 100000 PCI Memory DRAM available Note Actual memory availability to OS depends on the total amount of DRAM installed and the PCI resource usage 1MB to top of DRAM System BIOS See detailed map...

Страница 131: ...on 00 00 8086 3c00 0 Host bridge Intel Corporation Sandy Bridge DMI2 rev 07 IIO 0 00 01 8086 3c02 0 PCI bridge Intel Corporation Sandy Bridge IIO PCI Express Root Port 1a rev 07 IIO 0 00 01 8086 3c03...

Страница 132: ...Patsburg HECI Controller 2 rev 05 PCH 00 1a 8086 1d2d 0 USB Controller Intel Corporation Patsburg USB2 Enhanced Host Controller 2 rev 05 PCH 00 1c 8086 1d10 0 PCI bridge Intel Corporation Patsburg PC...

Страница 133: ...Bridge Power Control Unit 0 rev 07 IIO 0 7f 0a 8086 3cc1 1 System peripheral Intel Corporation Sandy Bridge Power Control Unit 1 rev 07 IIO 0 7f 0a 8086 3cc2 2 System peripheral Intel Corporation Sand...

Страница 134: ...ac 4 System peripheral Intel Corporation Sandy Bridge Inte grated Memory Controller Target Address Decoder 2 rev 07 IIO 0 7f 0f 8086 3cad 5 System peripheral Intel Corporation Sandy Bridge Inte grated...

Страница 135: ...8086 3c06 2 PCI bridge Intel Corporation Sandy Bridge IIO PCI Express Root Port 2c rev 07 I350 IIO 1 80 02 8086 3c07 3 PCI bridge Intel Corporation Sandy Bridge IIO PCI Express Root Port 2d rev 07 IIO...

Страница 136: ...Intel Corporation Sandy Bridge QPI Link Reut 0 rev 07 IIO 1 ff 09 8086 3c90 0 System peripheral Intel Corporation Sandy Bridge QPI Link 1 rev 07 IIO 1 ff 09 8086 3c93 3 System peripheral Intel Corpor...

Страница 137: ...roller RAS Registers rev 07 IIO 1 ff 0f 8086 3caa 2 System peripheral Intel Corporation Sandy Bridge Inte grated Memory Controller Target Address Decoder 0 rev 07 IIO 1 ff 0f 8086 3cab 3 System periph...

Страница 138: ...e DDRIO rev 07 IIO 1 ff 13 8086 3ce4 0 System peripheral Intel Corporation Sandy Bridge R2PCIe rev 07 IIO 1 ff 13 8086 3c43 1 Performance counters Intel Corporation Sandy Bridge Ring to PCI Express Pe...

Страница 139: ...nectors J10 J11 USB Connectors for the USB SSD Modules USB Connectors J12 Dual USB Connector Management Console Port J13 RJ 45 Serial Port Connector SFP Connectors J15 J17 Faceplate SFP Connectors AMC...

Страница 140: ...1 B59 RxD6 B102 RxD10 B145 RxD17 B18 12V B60 RxD6 B103 RxD10 B146 GND B19 GND B61 GND B104 GND B147 TxD18 B20 RxD1 B62 TxD6 B105 TxD11 B148 TxD18 B21 RxD1 B63 TxD6 B106 TxD11 B149 GND B22 GND B64 GND...

Страница 141: ...B41 ENABLE B83 PS0 GND B126 RxD14 B169 TDI B42 12V B84 12V B127 RxD14 B170 GND B85 GND B128 GND Signal Pin VCC 1 DATA 2 DATA 3 GND 4 Signal Pin Pin Signal RTS 1 5 GND DTR 2 6 RX TX 3 7 DSR GND 4 8 CT...

Страница 142: ...DC1 BI_DC1 6 BI_DA2 DI_DA2 BI_DB2 BI_DB2 DI_DC2 BI_DC2 7 N C N C N C N C N C N C 8 N C N C N C N C N C N C 9 N C N C N C N C N C N C 10 N C N C N C N C N C N C Pin ROW G ROW H ROW AB ROW CD ROW EF ROW...

Страница 143: ...ND GND GND GND 2 USB0_D USB0_D GND GND GND GND 3 JTAG_TRST FPGA_IO_2 GND GND GND GND 4 RTML_CLK PROG GND GND GND GND 5 RSVD_G5 JTAG_SEL GND GND GND GND 6 SFP0_SCL SFP0_SDA GND GND GND GND 7 SAS_1_RX S...

Страница 144: ...1_RX SAS1_RX GND GND GND GND 8 SAS0_RX SAS1_RX GND GND GND GND 9 N C MC_BLUE GND GND GND GND 10 MC_RED MC_GREEN GND GND GND GND Signal Pin Pin Signal N P 1 2 N P N P 3 4 N P HA0 5 6 HA1 HA2 7 8 HA3 HA...

Страница 145: ...on 0B5h Program registers on the channel level 0B6h Perform the JEDEC defined initialization sequence 0B7h Train DDR3 ranks 0B8h Initialize CLTT OLTT 0B9h Hardware memory test and init 0BAh Execute so...

Страница 146: ...tarted 0x12 Pre memory CPU initialization CPU module specific 0x13 Pre memory CPU initialization CPU module specific 0x14 Pre memory CPU initialization CPU module specific 0x15 Pre memory North Bridge...

Страница 147: ...Bridge initialization South Bridge module specific 0x3F 0x4E OEM post memory initialization codes 0x4F DXE IPL is started 0x50 Memory initialization error Invalid memory type or incompatible memory sp...

Страница 148: ...Bridge DXE initialization is started 0x6A North Bridge DXE SMM initialization is started 0x6B North Bridge DXE initialization North Bridge module specific 0x6C North Bridge DXE initialization North B...

Страница 149: ...n is started 0xA1 IDE Reset 0xA2 IDE Detect 0xA3 IDE Enable 0xA4 SCSI initialization is started 0xA5 SCSI Reset 0xA6 SCSI Detect 0xA7 SCSI Enable 0xA8 Setup Verifying Password 0xA9 Start of Setup 0xAA...

Страница 150: ...d StartImage returned error 0xDB Flash update is failed 0xDC Reset protocol is not available Status Code Description 0x01 System is entering S1 sleep state 0x02 System is entering S2 sleep state 0x03...

Страница 151: ...ad impact on your board To update your board from the update CD boot from the CD and follow the instructions provided in the AT8060 Update CD User guide provided with the CD image file A remote update...

Страница 152: ...ca kontron com EMEA support kom kontron com Or at the following address North America EMEA Kontron Canada Inc Kontron Modular Computers GmbH 4555 Ambroise Lafortune Sudetenstrasse 7 Boisbriand Qu bec...

Страница 153: ...the serial number of the defective product and a description of the problem E 2 When Returning a Unit In the box you must include the name and telephone number of a contact person in case further exp...

Страница 154: ...creased number of concurrent users of a multi Function device ASCII American Standard Code for Information Interchange ASCII codes represent text in computers communications equipment and other device...

Страница 155: ...Data Rate DDR3 DDR SDRAM or Double Data Rate 3rd Generation DHCP Dynamic Host Configuration Protocol DIMM Dual In line Memory Module DMA Direct Memory Access DMI Desktop Management Interface DRAM Dyn...

Страница 156: ...on HT Hyper Threading HW HardWare I2C Inter Integrated Circuit bus IA 32 Same as IA32 Intel Architecture 32 bits IA32 Same as IA 32 Intel Architecture 32 bits ICH I O Controller Hub ID IDentification...

Страница 157: ...ons Services Interface NEBS Network Equipment Building System NMI Non Maskable Interrupt OEM Original Equipment Manufacturer OOS Out Of Service OS Operating System PCB Printed Circuit Board PCH Platfo...

Страница 158: ...expansion ROM code used during POST to provide services for specific controllers such as boot capabilities RS 232 Same as RS232 Recommended Standard 232 RS232 Same as RS 232 Recommended Standard 232...

Страница 159: ...Thermal Design Power TLP Transaction Layer Packet TPM Trusted Platform Module UART Universal Asynchronous Receiver Transmitter UDP User Datagram Protocol An Internet Protocol UEFI Unified Extensible F...

Страница 160: ...l VTT Power supply VT100 Video Terminal 100 this is a communication standard VT d Intel R Virtualization Technology for Directed I O VT x Intel R Virtualization Technology for IA 32 Intel R Architectu...

Отзывы: