![Kontron AdvancedTCA AT8050 Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/kontron/advancedtca-at8050/advancedtca-at8050_user-manual_1996437068.webp)
52
AT8050
www.kontron.com
40
Vcc +1.1V
Threshold
Voltage on board 1.1V payload power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
41
Vcc +1.2V
Threshold
Voltage on board 1.2V payload power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
42
Vcc +1.5V
Threshold
Voltage on board 1.5V payload power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
43
Vcc +1.8V
Threshold
Voltage on board 1.8V payload power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
44
Vcc +3.3V
Threshold
Voltage on board 3.3V payload power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
45
Vcc +5V
Threshold
Voltage on board 5V payload power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
46
Vcc +2.5V REF
Threshold
Voltage on board 2.5V reference power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
47
Vcc +1.8V CPU
Threshold
Voltage on board 1.8V CPU power supply (Volts) Sensor type = 02h voltage Event
Reading type code = 01h threshold based see IPMI v1.5 section 29.13.3 for
threshold based event
48
Vcc Vddq
Threshold
Voltage on board Vddq payload power supply (Volts) Sensor type = 02h voltage
Event Reading type code = 01h threshold based see IPMI v1.5 section 29.13.3
for threshold based event
49
Vcc -48V A Feed
Threshold
Voltage on -48v feed A board input power supply (Volts) Sensor type = 02h
voltage Event Reading type code = 01h threshold based see IPMI v1.5 section
29.13.3 for threshold based event
50
Vcc -48V B Feed
Threshold
Voltage on -48v feed B board input power supply (Volts) Sensor type = 02h
voltage Event Reading type code = 01h threshold based see IPMI v1.5 section
29.13.3 for threshold based event
51
Feed A/B Status
Discrete
Feed A/B Redundancy Status. Sensor type = 08h Power Supply
Event Reading type code = 0Bh Discrete (Redundancy State), only offset 0,1 are
used, see IPMI v1.5 table 36.2, event reading type code 0Bh for sensor
definition
52
DIMM#1 SPD Pres
Discrete
DIMM#1 Temperature Sensor Presence Sensor type = 25h Entity Presence, Event
Reading type code = 6Fh Sensor specific, only offset 0,1 are used, -see IPMI v1.5
table 36.3, Sensor type code 25h (Entity Presence) for sensor definition
53
DIMM#2 SPD Pres
Discrete
DIMM#2 Temperature Sensor Presence Sensor type = 25h Entity Presence, Event
Reading type code = 6Fh Sensor specific, only offset 0,1 are used, -see IPMI v1.5
table 36.3, Sensor type code 25h (Entity Presence) for sensor definition
54
DIMM#3 SPD Pres
Discrete
DIMM#3 Temperature Sensor Presence Sensor type = 25h Entity Presence, Event
Reading type code = 6Fh Sensor specific, only offset 0,1 are used, -see IPMI v1.5
table 36.3, Sensor type code 25h (Entity Presence) for sensor definition
ID
Sensor Name
Sensor Class
Description (Sensor Type, Event trigger)