![Kontron 886LCD/ATUX Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/kontron/886lcd-atux/886lcd-atux_user-manual_1996434020.webp)
886LCD/ATX(GV) -/ATXU(GV)
KTD-00647-C
Public User Manual
Date: 2007-02-08 Page
20 of 71
4.2 Power Connector (ATXPWR, 12V)
The 886LCD/ATX(GV) and 886LCD/ATXU(GV) is designed to be supplied from a standard ATX power
supply.
ATX Power Connector 886LCD/ATX(GV) and 886LCD/ATXU(GV)
Note
Pull
U/D
Ioh/Iol
Type
Signal
PIN
Signal
Type
Ioh/Iol
Pull
U/D
Note
-
-
PWR
+12V 10 20
5V
PWR
-
-
-
-
PWR
SB5V 9 19
5V
PWR
-
-
4K7
-
I
P_OK 8 18
-5V
PWR
-
-
1
-
-
PWR
GND 7 17
GND
PWR
-
-
-
-
PWR
5V 6
16
GND
PWR
-
-
-
-
PWR
GND 5 15
GND
PWR
-
-
-
-
PWR
5V 4
14 PSON#
OC
-
-
-
-
PWR
GND 3 13
GND
PWR
-
-
-
-
PWR
3V3 2
12
-12V
PWR
-
-
-
-
PWR
3V3 1
11
3V3
PWR
-
-
Note: -5V supply is not used onboard.
+12V Power Connector 886LCD/ATX(GV) and 886LCD/ATXU(GV)
Note
Pull
U/D
Ioh/Iol
Type
Signal
PIN
Signal
Type
Ioh/Iol
Pull
U/D
Note
-
-
PWR
GND 4 3
+12V
PWR
-
-
-
-
PWR
GND 2 1
+12V
PWR
-
-
The requirements to the supply voltages are as follows (also refer to ATX specification version 2.03):
Supply Min Max Tolerance
3V3 3.14V
3.46V +/-5%
5V 4.75V
5.25V +/-5%
SB5V 4.75V
5.25V +/-5%
+12V 11.4V
12.6V +/-5%
–12V –13.2V
–10.8V +/-10%
Control signal description:
P_OK
Active high signal from the power supply indicating that the 5V and 3V3 supplies are within
operating limits. It is strongly recommended to use an ATX supply with the 886LCD/ATX(GV)
and 886LCD/ATXU(GV) boards, in order to implement the supervision of the 5V and 3V3
supplies. These supplies are not supervised onboard the 886LCD/ATX(GV) and
886LCD/ATXU(GV) boards.
PS_ON#
Active low open drain signal from the board to the power supply to turn on the power supply
outputs. Signal must be pulled high by the power supply.