background image

1.3. Indicators

Classification

Indicator

Description

Meaning

Ethernet

LINK

Network
status
indicator

Steady on

Network connection enabled

Flashing

Transmit or receive data

Off

The network port is not plugged into the

network cable

SPD

10/100Mbps
indicator

Steady on

100M network connected

Off

Not connected to the 100M network

RUN

FAULT

Equipment
failure
indicator

Steady on

Under voltage

Downstream
Serial Port

TXD

RS485 data
transmit
indicator

Flashing

RS485 transmitting data

Off

RS485 no transmitting data

RXD

RS485 data
receive
indicator

Steady on

RS485 line fault, please check if the

positive and negative poles of 485 line are reversed

Flashing

RS485 receiving data

Off

RS485 no receiving data

Power

PWR

Power
indicator
(9~27VDC)

Steady on

Normal power supply

Off

No power or abnormal power supply, please

check if the voltage range is 9~27VDC

C2000-RSDD-CK-CK31 User Manual

8 / 12

SinoCon Co., Ltd. 

www.sinoconsys.com

Содержание C2000-RSDD-CK-CK31

Страница 1: ...Last updated 2020 10 29 C2000 RSDD CK CK31 User Manual 3 RS485 1 RS485 Serial to Ethernet Device Serial to Serial Converter SinoCon Co Ltd...

Страница 2: ...rdware Description 1 1 Specifications 1 2 Apprearance 1 3 Indicators 1 4 Port Description 1 5 Product Dimensions 1 6 Installation Method 2 Package Contents 3 Warranty Policy C2000 RSDD CK CK31 User Ma...

Страница 3: ...liability stated by SinoCon in the terms and conditions of sale of its products and SinoCon makes no warranties regarding the sale or use of KonNaD products including the suitability for the specific...

Страница 4: ...C2000 RSDD CK CK31 User Manual 4 12 SinoCon Co Ltd www sinoconsys com...

Страница 5: ...l transparent transmission Baud Rate 1200 115200bps Upstream Serial Port Serial Standrad RS485 No of Ports 3 Connector Terminal block Baud Rate 1200 115200bps Cascade Connection Transparent Transmissi...

Страница 6: ...ental Limits Operating Temperature 40 85 Storage Temperature 60 125 Ambient Relative Humidity 5 95 RH non condensing Classification Parameter Specification C2000 RSDD CK CK31 User Manual 6 12 SinoCon...

Страница 7: ...1 2 Apprearance C2000 RSDD CK CK31 User Manual 7 12 SinoCon Co Ltd www sinoconsys com...

Страница 8: ...ator Steady on Under voltage Downstream Serial Port TXD RS485 data transmit indicator Flashing RS485 transmitting data Off RS485 no transmitting data RXD RS485 data receive indicator Steady on RS485 l...

Страница 9: ...PP1 Reserved port Power Input PE Used for reliable grounding of the device surge protection RVV 2 0 5 VA VA VB VB A channel power supply input positive A channel power supply input negative B channel...

Страница 10: ...1 5 Product Dimensions unit mm inch 1 6 Installation Method C2000 RSDD CK CK31 User Manual 10 12 SinoCon Co Ltd www sinoconsys com...

Страница 11: ...2 Package Contents No Contents 1 Device 1 2 Terminal block 1 set 3 Installation guide card 1 C2000 RSDD CK CK31 User Manual 11 12 SinoCon Co Ltd www sinoconsys com...

Страница 12: ...y period or that have been improperly installed incorrectly input voltage improperly used accidental events or natural disasters etc are not covered by the warranty 3 Before accepting the warranty ser...