background image

1. Hardware Description

1.1. Specifications

Classification

Parameter

Specification

Ethernet

No. of Ports

1

Bandwidth

10/100M

Communication Distance

100m

Industrial Protocols

TCP/IP

Downstream Serial
Port

Serial Standard

RS485

No. of Ports

1

Connector

Terminal block

Cascade Connection/Transparent
Transmission

Bidirectional transparent
transmission

Baud Rate

1200~115200bps

Upstream Serial Port

Serial Standrad

RS485

No. of Ports

3

Connector

Terminal block

Baud Rate

1200~115200bps

Cascade Connection/Transparent
Transmission

Bidirectional transparent
transmission

Communication
Mode

Communication Mode

Bidirectional transparent
transmission

Power

Power Connector

Terminal block

Input Voltage

9~27VDC

Current

< 200mA @ 12VDC

Physical
Characteristics

Dimensions

184*124*32.5mm

C2000-RSDD-CK-CK31 User Manual

5 / 12

SinoCon Co., Ltd. 

www.sinoconsys.com

Содержание C2000-RSDD-CK-CK31

Страница 1: ...Last updated 2020 10 29 C2000 RSDD CK CK31 User Manual 3 RS485 1 RS485 Serial to Ethernet Device Serial to Serial Converter SinoCon Co Ltd...

Страница 2: ...rdware Description 1 1 Specifications 1 2 Apprearance 1 3 Indicators 1 4 Port Description 1 5 Product Dimensions 1 6 Installation Method 2 Package Contents 3 Warranty Policy C2000 RSDD CK CK31 User Ma...

Страница 3: ...liability stated by SinoCon in the terms and conditions of sale of its products and SinoCon makes no warranties regarding the sale or use of KonNaD products including the suitability for the specific...

Страница 4: ...C2000 RSDD CK CK31 User Manual 4 12 SinoCon Co Ltd www sinoconsys com...

Страница 5: ...l transparent transmission Baud Rate 1200 115200bps Upstream Serial Port Serial Standrad RS485 No of Ports 3 Connector Terminal block Baud Rate 1200 115200bps Cascade Connection Transparent Transmissi...

Страница 6: ...ental Limits Operating Temperature 40 85 Storage Temperature 60 125 Ambient Relative Humidity 5 95 RH non condensing Classification Parameter Specification C2000 RSDD CK CK31 User Manual 6 12 SinoCon...

Страница 7: ...1 2 Apprearance C2000 RSDD CK CK31 User Manual 7 12 SinoCon Co Ltd www sinoconsys com...

Страница 8: ...ator Steady on Under voltage Downstream Serial Port TXD RS485 data transmit indicator Flashing RS485 transmitting data Off RS485 no transmitting data RXD RS485 data receive indicator Steady on RS485 l...

Страница 9: ...PP1 Reserved port Power Input PE Used for reliable grounding of the device surge protection RVV 2 0 5 VA VA VB VB A channel power supply input positive A channel power supply input negative B channel...

Страница 10: ...1 5 Product Dimensions unit mm inch 1 6 Installation Method C2000 RSDD CK CK31 User Manual 10 12 SinoCon Co Ltd www sinoconsys com...

Страница 11: ...2 Package Contents No Contents 1 Device 1 2 Terminal block 1 set 3 Installation guide card 1 C2000 RSDD CK CK31 User Manual 11 12 SinoCon Co Ltd www sinoconsys com...

Страница 12: ...y period or that have been improperly installed incorrectly input voltage improperly used accidental events or natural disasters etc are not covered by the warranty 3 Before accepting the warranty ser...

Отзывы: