4. Software Tools

4.1. Main Screen

The main screen displays the results of a broadcast search for the device.

Main Screen

1. Set: 

Set the device parameters

2. Remote Set: 

For Ethernet type devices, when the device is in the LAN but crosses multiple routers and

cannot be searched, the device parameters can be modified through 

Remote Set.

3. Change Password: 

Modify password of Ethernet type devices

4. Clear Password: 

Clear password of Ethernet type devices. If you need to clear the password, please contact

customer service.

5. Assistant: 

Help you debug the device, including Network Assistant, Serial Port Assistant, Analog

Conversion, Binary Conversion.

C2000-A2-SDD8020-DD3 User Manual

16 / 33

SinoCon Co., Ltd. 

www.sinoconsys.com

Содержание C2000-A2-SDD8020-DD3

Страница 1: ...Last updated 2020 1 10 C2000 A2 SDD8020 DD3 User Manual Ethernet 8DI 2DO Dry Wet contact Remote I O Module Ethernet Digital I O Module SinoCon Co Ltd...

Страница 2: ...I Data Auto upload 3 2 DO Control 3 2 1 DO Status 3 2 2 DO Power on Status 3 3 Other Features 3 3 1 DI Pulse Mode 3 3 2 Filter Parameters 3 3 3 Zeroing 3 3 4 DO Mode 4 Software Tools 4 1 Main Screen 4...

Страница 3: ...liability stated by SinoCon in the terms and conditions of sale of its products and SinoCon makes no warranties regarding the sale or use of KonNaD products including the suitability for the specific...

Страница 4: ...on for the recommended wires Check the following items after the device is powered on The PWR is steady red and the RUN is flashing which indicates the device is powered normally Plug the network cabl...

Страница 5: ...the installation 1 3 2 Device Debug Search Devices Select Search for Ethernet devices and Click Search to find all devices in the LAN Change IP Address Double click on the searched device or select th...

Страница 6: ...that has been searched click the Refresh button at the bottom right screen and you can see all the point value of the device DI1 DI8 The value 0 indicates Open the value 1 indicates Short to GND Use a...

Страница 7: ...Refer to Software Tools for more detailed information Refer to Registers for information on Secondary Development C2000 A2 SDD8020 DD3 User Manual 7 33 SinoCon Co Ltd www sinoconsys com...

Страница 8: ...Interval 6 sample periods Counter Frequency 1kHz Digital Output DO Channels 2 DO Connector Terminal block DO Type Form C DO Mode Logic level pulse Contact Capacity 30V 3A Ethernet No of Ports 1 Bandw...

Страница 9: ...rent 200mA 12VDC Physical Characteristics Dimensions 75 105 30mm Installation Din rail or wall Environmental Limits Operating Temperature 40 85 Storage Temperature 60 125 Ambient Relative Humidity 5 9...

Страница 10: ...2 2 Apprearance C2000 A2 SDD8020 DD3 User Manual 10 33 SinoCon Co Ltd www sinoconsys com...

Страница 11: ...100M network connected Off Not connected to the 100M network Downstream Serial Port RXD RS485 data receive indicator Steady on RS485 line fault please check if the positive and negative poles of 485...

Страница 12: ...ital Output NO Digital output normally open RVV 2 1 0 COM Digital output common RVV 2 1 0 NC Digital output normally close RVV 2 1 0 Ethernet Ethernet RJ45 Ethernet port CAT 5e Downstream Serial Port...

Страница 13: ...2 5 Product Dimensions unit mm inch 2 6 Installation Method C2000 A2 SDD8020 DD3 User Manual 13 33 SinoCon Co Ltd www sinoconsys com...

Страница 14: ...ess of DO status is 100 0x64 2 byte unsigned integer and the 0x01 function code is used to read DO status 0x05 function code is used to write single DO status and 0x0F function code is used to write m...

Страница 15: ...I logic level count value will be automatically cleared after each reading When set to manually clear DI positive negative pulse count and DI logic level count value will not be cleared every time and...

Страница 16: ...annot be searched the device parameters can be modified through Remote Set 3 Change Password Modify password of Ethernet type devices 4 Clear Password Clear password of Ethernet type devices If you ne...

Страница 17: ...device and you can modify the point value of the device 12 Refresh Used to refresh the point value of the device after it changes 4 2 Use Software 4 2 1 Device Settings Select Search for Ethernet dev...

Страница 18: ...e it will actively connect to the server Here the concept of the Socket of the Server Client is not to be confused with the application s Server Client Listening port The listening port waits for the...

Страница 19: ...to 2 Click Add to add the cascading device in the pop up 4 2 2 View Device Status After setting the IP address of the device and the computer on the same network segment click Refresh in the lower le...

Страница 20: ...it will be off DO Mode Pulse mode You can control the DO1 state by changing the DO1 Pulse width If the DO1 Pulse width is set to 6000 then set DO1 value to 1 the DO1 indicator will be on for 6000 ms...

Страница 21: ...t be searched the device parameters can be modified through Remote Set Click Remote Set in the upper left corner of the software the pop up dialog box to fill in the device IP address the port 21678 i...

Страница 22: ...ndary version 0x03 40105 2 IP address RW e g 10 1 1 11 0x0B01010A 1st register low 2 bytes of IP 0x010A 2nd register high 2 bytes of IP 0x0B01 0x03 0x06 0x10 40107 1 Modbus TCP port RW e g Default 502...

Страница 23: ...P port and waits for other devices to connect 2 In the client mode the device connects to the server through the server IP or domain name 0x03 0x06 0x10 40152 1 Reserved field RW Read as 0 write inval...

Страница 24: ...ther values are invalid 0x03 0x06 0x10 40316 8 DI1 DI8 positive pulse count RW Range from 0x0000 0xffff any value can be written After writing count from the written value 0x03 0x06 0x10 40324 8 DI1 D...

Страница 25: ...nels DI as an example The command is as follows 0x 000100000006FF0200C8000 Command Field Description 0001 Transaction ID 2 Bytes identification of a Modbus Request Response transaction 0000 Protocol I...

Страница 26: ...2 Bytes 0000 Modbus protocol 0006 Length Field 2 Bytes number of following bytes FF Unit ID 1 Byte 0xFF Master device 01 Function Code 1 Byte 01 Read 0064 Starting Address 2 Bytes address of the first...

Страница 27: ...odbus protocol 0008 Length Field 2 Bytes number of following bytes FF Unit ID 1 Byte 0xFF Master device 0F Function Code 1 Byte 0F Write 0064 Starting Address 2 Bytes address of the first register 000...

Страница 28: ...s 0000 Modbus protocol 0006 Length Field 2 Bytes number of following bytes FF Unit ID 1 Byte 0xFF Master device 05 Function Code 1 Byte 05 Write single register 0064 Starting Address 2 Bytes address o...

Страница 29: ...d In the response from the device we get Command Field Description 0001 Transaction ID 2 Bytes identification of a Modbus Request Response transaction 0000 Protocol ID 2 Bytes 0000 Modbus protocol 000...

Страница 30: ...ield 2 Bytes number of following bytes 01 Unit ID 1 Byte 01 RS485 address of the cascading device 02 Function Code 1 Byte 02 Read 01 Starting Address 2 Bytes address of the first register 03 Quantity...

Страница 31: ...00100000006010F00640004 Command Field Description 0001 Transaction ID 2 Bytes identification of a Modbus Request Response transaction 0000 Protocol ID 2 Bytes 0000 Modbus protocol 0006 Length Field 2...

Страница 32: ...6 Package Contents No Contents 1 Device contain mounting kit 1 2 Terminal block 1 set 3 Installation guide card 1 C2000 A2 SDD8020 DD3 User Manual 32 33 SinoCon Co Ltd www sinoconsys com...

Страница 33: ...period or that have been improperly installed incorrectly input voltage improperly used accidental events or natural disasters etc are not covered by the warranty 3 Before accepting the warranty serv...

Отзывы: