dial in the host or send SMS to program the phone number.
4. Connect the siren to alarm system.
Connect the black wire to GND port and red wire to siren port.
5. Connect wired sensors.
Three inputs are available to connect wired sensors. Inputs are independent, and are not coded as different zones.
Sensors must be NC (normally closed) type.
More than 1 sensor can be applied at one input, connecting their alarm contacts serial.
The inputs can be connected with any number of wired sensors, as long as total resistance is under 220 ohms.
When these sensors are triggered, the alarming message will be: Wired Activated (1~3).
6.
Connecting switched output devices (Home-appliance Control)
Three open outputs (O1, O2 and O3) and one internal relay controlled by telephone are available.
Internal onboard relay is activated when an alarm occurs and can be deactivated / reactivated through telephone
commands or SMS text message.
It can be used, for example, to command an external light.
Open outputs can be used directly if your equipment can operate a relay. Do connect an anti parallel diode with
relay coil. These outputs can be operated only by telephone or SMS text message commands.
Wiring Explanation: For home-appliance control (for special order)
The controller box has four wires:
1.
Two-yellow AC 220 wires to be connected with Home appliance.