Please read these assembly instructions carefully!
The STABLE and REPRESENTATIVE COLUMN is suited
for hospitals, surgeries, event halls, hotels, caterings,
schools as well as commercial and business premises.
It can be installed in entrances or waiting areas.
SAFETY INSTRUCTIONS
The safety of the stand depends on the:
GENERAL
Perform visual inspection before use:
Damaged components must not be used
- or only after a qualified repair or after
an exchange.
SQUARE BASE
Handle with care due to the heaviness, in particular,
do not drop (danger of crushing).
MOUNTING
Ensure that all screw connection are tight.
SURFACE
Only use the stand on suitable, i.e. level and
stable floors.
LOAD
Only for suitable 500ml bottles);
see below TECHNICAL DATA.
SURROUNDINGS
Negative external influences (knocks, dragging
around, vibrations, wind, wetness etc.) are to be
avoided or prevented.
INSTALLATION INSTRUCTIONS
Please carry out a visual check if all parts are
complete and as far as visible in order.
Provide the necessary keys.
A. COMPONENTS
a
.1
Square base
b.1
Base tube
b.2
Dispenser holder
b.3
Screw M5 x 16 mm (SW4)
c
.1
Elbow dispenser with PET bottle
Accessories bag (6-80350-1-00)
d.1
Flange head screw M6 x 16 mm (2x)
d.1
- wrench SW4
d.2
Cylinder head screw M8 x 25 mm (2x)
d.2
- wrench SW6
d.3
Washer ø 8,4 mm (2x)
d.4
Drip cup ø 70 mm
Accessories bag (6-80320-1-00)
e.1
Lock nuts M5-DIN985 (3x)
e.1
- wrench SW8
e.2
Washer ø 5,3 mm (3x)
e.3
Rounded head screw M5 x 16 mm (3x)
e.3
- Phillips screw Z2
B. STAND
1.1
Place square base
a
with felts on the floor
1.1
and then set up vertically.
1.2
Connect the base tube (b.1) to the square socket
a
.
1.2
Tighten the screws M8 x 25 mm, SW6
d.2
as well
1.2
as the washers ø 8.4 mm
d.3
.
1.3
Carefully set up the square base with the base tube.
C. DISPENSER HOLDER & DRIP CUP
2
The dispenser holder
b.2
is delivered in a
2
space-saving transport position and should
2
be rebuild as follows:
2.1
Separate the dispenser holder from the base tube
b.1
.
2.1
For this purpose, screw
b.3
has to be completely
2.1
removed.
2.2
Now place the dispenser holder correctly:
2.2.1
The opening for the drip cup should protrude
2.2.1
into the centre of the square base.
2.2.2
Holder and base tube are connected by means
2.2.2
of the flange head screws M6x16, SW4
d.1
2.3
Press the drip cup
d.4
from above back into the
2.3
opening of the holder. For cleaning or other
2.3
purposes, it can be removed again.
80358 Disinfectant column stand
80358
including dispenser
KÖNIG & MEYER
GmbH & Co. KG
Kiesweg 2, 97877 Wertheim, www.k-m.de
80358-000-56/66 Rev.1a 03-79-927-00 7/20
Tightening torque: max. 6 Nm
A. COMPONENTS
B. STAND
C. DISPENSER HOLDER