E-7
<If you install Finisher FS-535/FS-534SD/FS-534
after this installation>
(5) Measure width A of the test pattern on the back-
side of the test print produced and check to see if
it falls within the specified range.
Specifications: 3.0 mm ± 1.0 mm
•
Adjusting paper reference position
(Coarse adjustment)
Make this adjustment if the measured width A
falls greatly outside the specified range.
(6) Slide the drawer out from the paper feed cabinet.
(7) Loosen the six screws of the drawer (Left: tow
screws, Right: four screws) shown in the illustra-
tion.
(8) Move the front cover assy while looking at the
tick marks on the scales placed near the screws.
•
If the width A is greater than the specifications:
Move the front cover assy to the
➀
direction.
•
If the width A is smaller than the specifications:
Move the front cover assy to the
➁
direction.
(9) Tighten the six screws which have been loos-
ened in step (7).
(10) Produce another test print and check to see if
width A falls within the specified range.
Note:
Make the adjustment until width A falls within the
specified range.
•
Adjusting paper reference position (Fine adjust-
ment)
If the measured width A falls slightly outside the
specified range, enter the correction value
using the
or
key.
(11) Produce another test print and check to see if
width A falls within the specified range.
Note:
Make the adjustment until width A falls within the
specified range.
Paper exit
direction
A
Screws
Screws
➁
➀
Scale
Scale