Disable L2 Cache.
(Disable the use of L1 cache)
Disable L1 Cache.
(Disable the use of L2 cache)
00000640K Low Memory Passed
(Test memory between 64KB and 640KB)
00064512K Ext Memory Passed
(Test memory above 640KB)
Check Key In.
(Check keyboard input)
PCI Device Table.
(List of PCI devices)
Bus
Dev
Func
VendID
DevID
Class
Irq
00
00
00
8086
7190
Host Bridge
00
01
00
8086
7191
PCI-to-PCI Bridge
00
07
00
8086
7110
ISA Bridge
00
07
01
8086
7111
IDE Controller
00
07 02
8086
7112
Serial
Bus
10
00
07
03
8086
7113
PCI Bridge
00
11
00
4B43
505E
Konica PCI Device
11
00
12
00
4B43
5859
Konica PCI Device
3
00
12
01
4B43
5859
Konica PCI Device
3
00
12
02
4B43
5859
Konica PCI Device
3
00
12
03
4B43
5859
Konica PCI Device
3
00
12
04
4B43
5859
Konica PCI Device
3
00
12
05
4B43
5859
Konica PCI Device
3
00
12
06
4B43
5859
Konica PCI Device
3
00
12
07
4B43
5859
Konica PCI Device
3
00
13
00
4B43
5050
Konica PCI Device
5
Test Hard Disk Drive.
(Search for and initialize hard disk drive)
Init Coprocessor.
(Initialize Coprocessor)
Enable Cache Memory.
(Enable the use of cache memory)
Enable Coprocessor INT & NMI.
(Enable .NMI. Initialize Coprocessor)
Enable Clock Ctrl.
(Set the clock control)
Boot!
(Load and start OS)
Error List
When an error that relates to the system boot occurs while running POST, "Critical Error" is output and dis-
played via the service port, and the system boot is interrupted.
The following can cause a critical error:
•
The memory area under 640 KB cannot be accessed
•
There is a faulty memory refresh
•
There is an error reading/writing CMOS memory
•
The CPU timer does not operate correctly
•
The interrupt controller does not operate correctly
If the POST is interrupted due to an error other than those above, there may a system fault. In this case,
check the "Details of the Service Port Output" and look for an error.
If this kind of error occurs, the system cannot boot and the copier and print controller will not be able to com-
municate, and communication errors will occur with the controller after the copier has started.
Содержание IP-422
Страница 1: ...KONICA BUSINESS TECHNOLOGIES INC SERVICE MANUAL Models IP 422 IP 423 CSM IP422 423 OCTOBER 2002...
Страница 2: ......
Страница 3: ...IP 422 IP 423 SERVICE MANUAL OCTOBER 2002...
Страница 16: ...SAFETY AND IMPORTANT WARNING ITEMS S 10...
Страница 17: ...Overview 1...
Страница 18: ...Blank Page...
Страница 26: ...Chapter 1 Overview 1 8...
Страница 27: ...Disassembly Reassembly 2...
Страница 28: ...Blank Page...
Страница 41: ...Field Service 3...
Страница 42: ...Blank Page...
Страница 65: ...Troubleshooting 4...
Страница 66: ...Blank Page...
Страница 77: ...Appendix...
Страница 78: ...Blank Page...
Страница 88: ...Appendix Appendix 10 MEMO...