Measuring geometry
Detector
Wavelength range
Wavelength pitch
Half bandwidth
Photometric range
Light source
Measurement time
Illumination/
measurement areas
Repeatability
Inter-instrument
agreement
Temperature drift
UV adjustment
Specimen conditions
for transmittance
measurements
Interface
Power
Operation temperature/
humidity range (*1)
Storage temperature/
humidity range
Dimensions (W
×
H
×
D)
Weight
Standard accessories
Optional accessories
*1 Operating temperature/humidity range of products for North America : 13 to 33 C, relative
humidity 80% or less (at 31 C) with no condensation
•
Specifications are subject to change without notice.
55
12
7
271
500
128.5
143
259
247
482
41.8
Dimensions
(Units:mm)
Reflectance: di:8 , de:8 (diffuse illumination/8 viewing angle);
SCI (specular component included )/SCE(specular component
excluded) switchable; meets CIE, ISO, ASTM, and DIN standards.
Transmittance: di:0 , de:0 (diffuse illumination/0 viewing angle)
Silicon photodiode array with flat holographic grating
360 to 740nm
10nm
Approx. 14nm average
0 to 200%; Resolution: 0.001%
Pulsed xenon arc lamp
0.6 to 0.8 sec. (to start of data output)
Reflectance: Changeable between LAV, MAV, and SAV
LAV: ø28mm illumination/ø25.4mm measurement
MAV: ø11mm illumination/ø8mm measurement
SAV: 5
×
7mm illumination/3
×
5mm measurement
Transmittance: Approx. ø20mm
When white calibration plate is measured 30 times at 10-sec.
intervals after white calibration has been performed:
Spectral reflectance: Standard deviation within 0.05%
Chromaticity: Standard deviation within
Δ
E*ab0.005
When black tile(BCRA Series II ; reflectance: 1%)is measured 30 times
at 10-second intervals after white calibration has been performed:
Spectral reflectance: 380 to 740nm: Standard deviation within 0.02%
360 and 370nm: Standard deviation within 0.04%
Chromaticity: Standard deviation within
Δ
E*ab0.05
mean
Δ
E*ab0.08 (typical) Average for 12 BCRA Series II color tiles.
Max
Δ
E*ab0.3(corresponds to approx.
Δ
E*
CMC
0.2) for any of 12 BCRA
Series II color tiles compared to values measured with master body ; LAV.
Spectral reflectance: Within
±
0.10%/ C,
Color difference: Within
±Δ
E*ab0.05/ C
Computer controlled: continuously variable
Sheet, plate, or liquid form up to a maximum thickness of
approximately 50mm
RS-232C standard; baud rates: 1200,2400,4800,or 9600
AC 100V/120V/230V 50/60Hz (using included AC adapter)
13 to 33 C, relative humidity 80% or less with no condensation
0 to 40 C, relative humidity 80% or less with no condensation
271
×
259
×
500mm(10-11/16
×
10-3/16
×
19-11/16 in.)
18kg(39.7 lb.)
White Calibration Plate; Target Mask(3
×
5mm);
Target Mask(ø8mm); Target Mask(ø25.4mm);
Zero Calibration Box; AC Adapter;
RS-232C Cable(9-pin, 2m);
Accessory Case CM-A66
Transmittance Specimen Holder; Glass Cells(2mm, 10mm, 20mm);
Plastic Cells(2mm, 10mm, 20mm);
Transmittance Zero Calibration Plate; Color Tiles;
RS-232C Cable(9-pin, 5m)
Optional Accessories
Transmittance Specimen
Holder CM-A96
Holds specimens in place for trans-
mittance measurements. Maximum
specimen thickness: 22.5mm
Glass Cell
CM-A97/CM-A98/CM-A99
Hold liquid specimens for transmit-
tance measurements. Optical path
lengths: 2mm (CM-A97), 10mm
(CM-A98), and 20mm (CM-A99)
Plastic Cells CM-A130(2mm),
CM-A131(10mm),CM-A132(20mm)
are also available.
Transmittance Zero
Calibration Plate CM-A100
For performing zero calibration for
transmittance measurements.
Color Tiles
14 color tiles are available: White, Pale grey,
Middle grey, Difference grey, Deep grey, Deep
pink, Red, Orange, Bright yellow, Green,
Difference green, Cyan, Deep blue, Black. Original
materials of these tiles are supplied by BCRA.
Specifications (CM-3700d)
SAFETY PRECAUTIONS
For correct use and for your safety, be sure to read the instruction
manual before using the instrument.
Always connect the instrument to the specified power supply
voltage. Improper connection may cause a fire or electric shock.
Содержание CM-3700D
Страница 1: ...CM 3700d SpectraMagicTM NX Optional...