bizhub C554/C454/C364/C284/C224
2-57
2.12
Protecting Data in the HDD
2
7
Make sure that a message appears prompting you to turn OFF and then ON the main power switch.
Now, turn OFF and then turn ON the main power switch.
%
When the main power switch is turned off, then on again, wait at least 10 seconds to turn it on after
turning it off. if there is no wait period between turning the main power switch off, then on again, the
machine may not function properly.
Here is the sequence, through which the main power switch and sub power key are turned on and
off:
Turn off the sub power key
ö
Turn off the main power switch
ö
Turn on the main power switch
ö
Turn on the sub power key
8
The following screen appears after the machine has been restarted.
9
Call the Administrator Settings on the display from the control panel.
%
For the procedure to call the Administrator Settings on the display, see page 2-2.
10
Touch [HDD Format].