bizhub 423/363/283/223
2-73
2.16
SNMP Setting Function
2
12
Touch [Write priv].
%
When a screen appears that prompts you to enter the current password, enter the MAC Address
that is set in the machine. To check the MAC Address, from [Network Settings] of step 2, select [For-
ward]
→
[Detail Settings]
→
[Device Setting].
%
The entry of a wrong SNMP password (auth-password, priv-password) is counted as unauthorized
access, if the Enhanced Security Mode is set to [ON]. If a wrong SNMP password (auth-password,
priv-password) is entered a predetermined number of times (once to three times) or more set by the
Administrator of the machine, the machine is set into an access lock state, rejecting any more logon
attempts. To cancel the access lock state, perform the Release Setting by the Administrator of the
machine.
13
Enter the new 8-digit-or-more priv-password from the keyboard or keypad.
%
Press the [C] key to clear all characters.
%
Touch [Delete] to delete the last character entered.
%
Touch [Shift] to show the upper case/symbol screen.
%
Touch [Cancel] to go back to the previous screen.
14
Touch [OK].
%
If the entered priv-password does not meet the requirements of the Password Rules, a message
that tells that the entered priv-password cannot be used appears. Enter the correct priv-password.
For details of the Password Rules, see page 1-8.
Содержание bizhub 223
Страница 5: ...1 Security ...
Страница 16: ...2 Administrator Operations ...
Страница 111: ...3 User Operations ...
Страница 148: ...4 Application Software ...
Страница 185: ...User s Guide Security Operations http konicaminolta com Copyright 2010 A1UD 9610B 00 2010 6 Ver 1 00 A1UD 9610B 00 BK ...