E-8
XI. ATDC Adjustment
1. Install the imaging unit (IU) in position.
2. Close the right door.
3. Select functions in this order: Tech. Rep. Mode
→
Function
→
F8.
4. Press the Start key to run an F8 operation. (At
this time, the Start key changes to orange.)
5. When the Start key changes to blue, touch
“END.”
6. Press the Reset key.
7. Touch “Exit” on the Tech. Rep. Mode screen to
go back to the initial screen.
XII. Installing the Toner Bottle
Note:
The toner bottle is not shipped with the machine.
Purchase one that is separately available.
1. From a height of about 10 cm, tap the toner bottle
against a table or other hard object four to five
times. Then turn it upside down and repeat the
same procedure.
Note:
Toner can cake in the toner bottle. Be sure to per-
form this procedure.
2. Shake the toner bottle well about five times in the
vertical direction. Then, turn it over and repeat
the same procedure.
3. Open the front door and slide the toner hopper
out of the machine.
A11UIXC025MA
A11UIXC026MA
A11UIXC027MA
A11UIXC028MA
A11UIXC029MA